Etfective Orifice (mm2) NPTF (Base mount type) 1 1 3 02=1h 03 = 3/s I .t 1 30 Q2=1/t 03=9e O4=1/z 1 45 03 =3/8 04=1/z 06=aa (Base mount type) 1 2 02=lL 03 = 3/s 8 4.5 4 ?.

(g) 120 1 1 0 100 90 80 l|AN20002 U1 35 (1.9) .04 (17) NAN3OO-N03 % 60 (3.3) .06 t25) NANtrco+to4 90 (5.0) .08 (35) 60 NAN50(rN0,6 3A 160 (8.8) .36 (165) NAN6OO.NI O 1 27O llsl .46 e25) NAN700+i12 1]4 444 Q4l 1 .87 (4901 Supply pressure: 7l PSI Distance from silencer: NAN200-500-) 31t NAN6O0-7OO+ 6.5fi MN800_900 ,10f1 NANSOO-N,'4 1\h 590 (33) 2.21 (580) NANgOO-N2O 2 960 (53) 3.13 (820) Construction

N.O. 100 Electrical Terminology 1. Surge voltage A high voltage which is momentarily generated in the shut-off unit by shutting off the power. VCW 7 Cv=1.38 3 4 VCW 10 Cv=2.1 3 4 VCW4 5 Cv=0.85 VCW2 2 Cv=0.16 10 Flow rate Ql /min 5.0 Other 1. Materials NBR: Nitrile rubber FKM: Fluoro rubber Trade names: Viton, Dai-el, etc.

Part Number Description: L-TYPE BRACKET NAC4000-06 ONLY   Product Line: E   Product Line Description: AIRLINE EQUIPMENT   Family Code: 100   Family Description: AC FRL COMBO   Class Code: 22   Part Code: 2   Reference Code:  B   Click here to report information errorImage shown may not match exact part number, L-TYPE BRACKET NAC4000-06 ONLY, AIRLINE EQUIPMENT, AC FRL COMBO, 22, AC NO

AS Series How to Order 2 2 0 01 06 W2 AS 1F Body size 2 1 M5 standard 1/8, 1/4 standard 3/8 standard 1/2 standard 3 4 Metric size Applicable tubing O.D. Note) Elbow 06 08 10 12 6 8 10 12 Control type Meter-out Meter-in 0 1 Note) For applicable tubing O.D. selection, refer to the Model on page 603.

Made to Order How to Order 2 1 F 06 200 AS S Lubricant: Vaseline -X12 Example) AS2002FS-04-X12 Made to Order Body size Grease-free (Seal: Fluorine-coated) + Restrictor (Without check valve) -X21 100 M5 standard 200 1/8 standard 205 1/4 standard 300 3/8 standard 400 1/2 standard Applicable tubing O.D.1 Example) AS2002FS-04-X21 Not particle-free Metric size Inch size 23 3.22 04 4 06 6 08 8

Available in 1/8 ~ 1 Tube Diameters, For All Body Series Class 100 Cleaning & Packaging Series LVQ HowT o Order LVQ 2 0 S 07 Body Class Space Saving Option Symbol 2 3 4 5 6 Body Class 2 3 4 5 6 Orifice Dia. 4 8 10 16 22 S Space saving connection Pilot Connection Nil M N LQ LQ Thread type 1/8 diameter 5/32 (4mm) NPT1/8 Diff. Dia.

OUT 1 Thread type Rc NPT NPTF G Nil N T F IN Voltage 1 2 3 4 5 6 36 100VAC 200VAC 110VAC 220VAC 24VDC 12VDC 230VAC Port size Class 3 Class 2 Port size 1/8 (6A) 1/4 (8A) 3/8 (10A) 1/2 (15A) 3/4 (20A) Class 4 Symbol 01 02 03 04 06 Class B with AC has a built-in rectifying circuit. Class H is AC only. Without rectifying circuit. Contact SMC regarding other voltages.

Class 3 Class 2 Symbol 01 02 03 04 06 1 2 3 4 36 100VAC 200VAC 110VAC 220VAC 230VAC Orifice size Class 3 Class 4 Class 2 Orifice diameter 2mm 3mm 4mm 5mm 7mm 10mm Symbol 2 3 4 5 7 10 Electrical entry CConduit GGrommet Refer to the table below for orifice and port size combinations.

100 N JCM CDG3 L 100 M9BW N 25 C With auto switch CM2 With auto switch (Built-in magnet) CM3 Made to Order For details, refer to page 366.

V to +400 V +30 V to +100 V Within 30 V 30 V to 100 V 100 V to 400 V 400 V or lower Light ON Positive Static neutralization completion Flash at 4 Hz Detects the electric potential difference and outputs in an analog voltage.

Mounting CG1 Front/Rear trunnion styles are not available for bore sizes 80 and 100.

: (800) 258-9200-www.stevenengineering.com 16 A 29 Auto switch B A 26 Auto switch B D-B5/B64/B59W 20 to 40 D-G5/K59/G5W/K59W/G5NTL, D-G5BAL 20 to 40 HS HS A B B A Auto switch 50 to 100 50 to 100 HS HS 12 12 SMC SMC 24.5 24.5 A 33 B A 33 Auto switch B D-C73C/C80C 20 to 40 D-H7C 20 to 40 HS HS Auto switch Auto switch B A B A 50 to 100 50 to 100 HS HS 8.5 8.5 SMC SMC 16 16 A 36.7 Auto

2 Section B Section C 100 80 63 50 40 32 80, 100 80, 100 Description Material Note Parts list Description Material Note Parts list No. No.

How to Order 100 TS0604 W Length per roll Color Tubing model Symbol Length Symbol Color Color Symbol 20 20 m roll B Black BU Blue Y Yellow G Green 100 100 m roll (Black and white only) W White R Red Made to Order (Please contact SMC for specifications in detail, dimensions, delivery and specifications other than those mentioned above.) 100 m reel Metric size and Inch size except 16: Suffix

4 150, 200, 250, 300 3/8 1/2 25, 50, 75, 100, 125, 150, 200 100 Non-lube Double acting, Double rod (40 to 63) 20 25 32 40 50 63 80 100 1/8 25, 50, 75, 100, 125, 1/4 150, 200, 250, 300 3/8 1/2 Suction Flow Rate of Vacuum Suction Type (Reference values) Specifications Bore size (mm) Item 20 25 32 40 50 63 80 100 Size Suction flow rate L/min (ANR) 20/25/32/40 50/63/80/100 1.5 MPa 1.0 MPa

20 11 22 14 60 60 129 MB-SIO . 100 11 4 \20 90 15 158 132 \84 26 13.5 24 17 75 100 '29 25 +008001 (mm) [~ "r.

62 3/4 180.5 124.9 135 MVGQ CCVL1-G-S 66 107 116 50 24 40 28 2 40 27 100 80 3/4 135 180.5 132.8 135 M6 x 1 10.5 to 12.5 CCVL2-G-S 66 107 116 50 24 40 28 1 40 27 115 100 80 3/4 135 180.5 124.9 135 CC CCVL3-G-S 66 66 107 107 116 116 50 50 24 40 28 28 1 40 40 27 27 115 115 100 100 80 80 3/4 135 135 180.5 124.9 135 CCVL0-S 3/4 RB Pitch of mounting on the wall is CA and CL.

CKGA80, 100/CKPA80, 100/With Magnetic Field Resistant Auto Switch (Rod Mounting Type) 1 P3DWASC CK G A 80 Y Built-in standard magnet type with magnetic field resistant auto switch 100 Built-in strong magnet type with magnetic field resistant auto switch 100 P79WSE CK P A 80 Y Built-in standard magnet Number of auto switches Nil S 2 pcs. 1 pc.