: 48.4 N02: 48.9 Atmospheric vent port 02 4 x 2.6 Depth 7 or less 20 30 25 8.5 11 R1/4 M5 x 0.8 Thread depth 5 4.2 N02 30 20 NPT1/4 17 Piping port 02: R1/4 N02: NPT1/4 2.5 If there is a possibility that the atmospheric vent port of the switch will be exposed to water or dust, insert a tube into the atmospheric vent port and route the other end of the tube to a safe place away from water or
VT Port size Type of actuation VP342 VP344 VP542 VP544 VP742 VP744 Port size Rc Without sub-plate Nil VP Symbol Common use to normally closed and normally open (Pilot) 4 VG Body type 01 1 8 02 1 4 03 3 8 1 2 04 Body ported 2 Base mounted 4 VP Valve option VP344, VP544, or VP744 only.
Piping port ZSM 02: Rc1/4 N02: NPT1/4 F02: G1/4 (ISO1179) PF2 IF 2 1 Data 4 3 With bracket Connector Pin Assignments 44.5 9 34 Output -43 MPa 1 Brown DC (+) 2 White OUT1 (PNP) 3 Blue DC () OUT1 4 Black OUT1 (NPN) U P DOWN SET Output -65 14.5 90 1 Brown DC (+) 2 White NC 3 Blue DC () 26.5 4 Black OUT1 (PNP) 18.3 6 (28.7) 35 46 (38.2) 60 24 Piping port 02: Rc1/4 N02: NPT1/4 F02: G1/4 (ISO1179
H2 L3 L2 L1 All Ports: Screw-in Model H1 H2 H3 L1 L2 L3 L4 Connection thread 1 Connection thread 2 Connection thread 3 ZH05DA-01-01-01 12 12 12 67 42.5 27 26 Rc1/8 Rc1/8 Rc1/8 ZH07DA-01-01-01 70.2 ZH10DA-01-01-01 76.4 ZH13DA-01-02-02 17 17 90.8 51 29.5 36.3 Rc1/4 Rc1/4 ZH15DA-02-03-03 17 19 19 108.2 63.3 34.3 37.1 Rc1/4 Rc3/8 Rc3/8 ZH18DA-03-03-03 19 131.1 73.6 41.1 39.1 Rc3/8 ZH20DA-03-04
A Note 1) 4 6 4 6 8 4 6 8 10 6 8 10 12 10 12 AS121FP-M5-04 AS121FP-M5-06 AS221FP-01-04 AS221FP-01-06 AS221FP-01-08 AS221FP-02-04 AS221FP-02-06 AS221FP-02-08 AS221FP-02-10 AS321FP-03-06 AS321FP-03-08 AS321FP-03-10 AS321FP-03-12 AS421FP-04-10 AS421FP-04-12 28 7 7 18.4 23.2 8 10.4 22.2 25 25.5 28.3 9.6 M5 x 0.8 12.2 29 8 8 19.4 24.2 12.8 32.4 17 17 18.4 25.3 10.4 27.4 32.4 31.4 36.4 14.2 12
A Note 1) AS121FP-M5-04 AS121FP-M5-06 AS221FP-01-04 AS221FP-01-06 AS221FP-01-08 AS221FP-02-04 AS221FP-02-06 AS221FP-02-08 AS221FP-02-10 AS321FP-03-06 AS321FP-03-08 AS321FP-03-10 AS321FP-03-12 AS421FP-04-10 AS421FP-04-12 4 6 4 6 8 4 6 8 10 6 8 10 12 10 12 28 7 7 18.4 23.2 8 10.4 22.2 25 25.5 28.3 9.6 M5 x 0.8 12.2 29 8 8 19.4 24.2 12.8 32.4 17 17 18.4 25.3 10.4 27.4 32.4 31.4 36.4 14.2 12
Note 4) Values for the low wattage (0.5W) specification. (A) 4 (B) 2 3 (R2) 1 (P) 5 (R1) 4 position dual 3 port valve (A) 4 2 5 3 1 N.C. N.C. 4 position dual 3 port valve (B) 4 2 5 3 1 N.O. N.O. 4 position dual 3 port valve (c) 2 4 5 3 1 N.C.
(different sides/same side) 10 100 100 110 120 D-A5, D-A6 D-F5, D-J5 (n 4) 2 (n 4) 2 (n 4) 2 (n 4) 2 (n 2) 2 "n" pcs. (same side) 10 + 55 110 + 55 120 + 55 100 + 55 100 + 55 n = 2, 4, 6, 8 n = 4, 8, 12, 16 n = 4, 8, 12, 16 n = 4, 8, 12, 16 n = 4, 8, 12, 16 2 pcs. (different sides/same side) 20 100 100 110 120 D-A59W (n 4) 2 (n 4) 2 (n 4) 2 (n 4) 2 (n 2) 2 "n" pcs.
thread (Rc, G, NPT/NPTF) 1/2 [1(P) port] 11.5 101.2 15.7 8 95.5 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 77.3 72 56.6 43.5 42.7 A 4 A 4 A 4 A 4 A 4 A 4 A 4 A 4 20.6 21.5 11.5 1/8: 1/8" female thread (Rc, G, NPT/NPTF) 1/8 (External pilot port) 27 31 1/8: 1/8" female thread (Rc, G, NPT/NPTF) 1/8 (Pilot EXH port) 38.7 (6.5) 25 65.5 1/4, 3/8, C8, C10, C12 [4(A), 2(B) port] 1/4: 1/4" female thread (Rc
A (2) AS121FP-M5-04 AS121FP-M5-06 AS221FP-01-04 AS221FP-01-06 AS221FP-01-08 AS221FP-02-04 AS221FP-02-06 AS221FP-02-08 AS221FP-02-10 AS321FP-03-06 AS321FP-03-08 AS321FP-03-10 AS321FP-03-12 AS421FP-04-10 AS421FP-04-12 4 8 10.4 22.2 17 27 7 7 12.2 28.8 26 M5 x 0.8 9.6 25.2 22.4 6 12.8 23.2 18.5 8 8 28 (12.2) (28.8) (26) 4 10.4 24.3 17 17 17 31.4 13.4 35.5 30.5 6 R 1/8 12 14.2 32.4 27.4 12.8
A (2) AS121FP-M5-04 AS121FP-M5-06 AS221FP-01-04 AS221FP-01-06 AS221FP-01-08 AS221FP-02-04 AS221FP-02-06 AS221FP-02-08 AS221FP-02-10 AS321FP-03-06 AS321FP-03-08 AS321FP-03-10 AS321FP-03-12 AS421FP-04-10 AS421FP-04-12 4 8 10.4 22.2 17 27 7 7 12.2 28.8 26 M5 x 0.8 9.6 25.2 22.4 6 12.8 23.2 18.5 8 8 28 (12.2) (28.8) (26) 4 10.4 24.3 17 17 17 31.4 13.4 35.5 30.5 6 R 1/8 12 14.2 32.4 27.4 12.8
Blow setting Trigger setting 0 Slide Trigger linked 1 Trigger lock 2 OFF timer 3 s 3 5 s 4 7 s 5 Continuous blow Trigger linked 6 Trigger lock 7 OFF timer 3 s 8 5 s 9 7 s Pulse blow Mode setting switch Wiring AC adapter type IZG10-m01, 02 Connect the M8 connector on the power cable for AC adapter to the power connector on the main unit.
-W-m +HRL-JK001 G1/2 G1/2 G1/2 G1/4 G3/8 G3/4 HRL-EP018 NPT thread conversion fitting set NPT1/2 NPT1/2 NPT1/2 NPT1/4 NPT3/8 NPT3/4 HRL-EP011 G thread conversion fitting set HRLE090-A-m +HRL-JK001 G1 G1/2 G1/4 G3/8 G3/4 HRL-EP012 NPT thread conversion fitting set NPT1 NPT1/2 NPT1/4 NPT3/8 NPT3/4 HRL-EP013 G thread conversion fitting set HRLE090-W-m +HRL-JK001 G1 G1/2 G1/2 G1/4 G3/8 G3/4
A Note 1) 4 6 4 6 8 4 6 8 10 6 8 10 12 10 12 AS121FP-M5-04 AS121FP-M5-06 AS221FP-01-04 AS221FP-01-06 AS221FP-01-08 AS221FP-02-04 AS221FP-02-06 AS221FP-02-08 AS221FP-02-10 AS321FP-03-06 AS321FP-03-08 AS321FP-03-10 AS321FP-03-12 AS421FP-04-10 AS421FP-04-12 28 7 7 18.4 23.2 8 10.4 22.2 25 25.5 28.3 9.6 M5 x 0.8 12.2 29 8 8 19.4 24.2 12.8 32.4 17 17 18.4 25.3 10.4 27.4 32.4 31.4 36.4 14.2 12
G Stainless steel Body material Applicable tubing O.D. 04 06 08 10 12 4 6 8 10 12 Body size 2 Elbow Type 2 3 4 5 6 M5 1/8 1/4 3/8 1/2 Control type Port size 0 1 Meter-out Meter-in M5 01 02 03 04 M5 x 0.8 R1/8 R1/4 R3/8 R1/2 With one-touch fitting 1 Series ASG Needle Valve: Flow Characteristics ASG220F-M5 ASG221F-M5 ASG320F-01 ASG321F-01 ASG420F-02 ASG421F-02 1.5 Inlet pressure: 0.5 MPa Inlet
1/4, 3/8 3/8, 1/2 3/4 VCA41 4 Series VCA How to Order Manifolds (VCA20) VV2C A 2 02 02 How to Order Manifold Assemblies (Example) Enter the valve and option models to be mounted under the manifold base part number.
1 to 30 psig (0.007 to 0.2 MPa) 1 to 60 psig (0.007 to 0.4 MPa) 2 to 100 psig (0.014 to 0.7 MPa) Bonnet option 02 06 10 Bonnet Standard Panel installation 4) Code No code P Connections (Inletq, Outletw) 4) Panel mounting hole: dia. 1.56 inch (39.6 mm).
Model Pressure range *1 Indication unit Connection thread Note MPa Port size 01 Rc1/8 02 Rc1/4 R1/8 R1/4 G46-7-02-SRB 0 to 0.7 R1/4 G46-10-02-SRB 0 to 1.0 G46-4-01 to 02-SRB 0 to 0.4 MPa Set pressure range: 0.05 to 0.69 MPa 02 WR110 X215 *1: Do not apply more pressure than the max. pressure displayed. It may cause a malfunction.
How to Order Internal pilot operated relieving type regulator AR 25 4 BG 02 Semi-standard Nil Flow direction: Right to left None (Standard) Regulator R Body size Port size Accessory 4 6 8 9 1 2 1 Symbol 1 Description Applicable model 02 03 04 06 10 12 14 20 1 4 Nil 2 1 8 3 B With bracket AR4 5 to 6 5 AR 25 AR 35 2 1 2 3 4 Gauge G46-10-02 G46-2-02 G Regulating pressure range 1 G46-P10-02-X30
1/4, 3/8 3/8, 1/2 3/4 VCA41 17-2-13 8 Series VCA How to Order Manifold (VCA20) How to Order Manifold Assembly VV2C A 2 02 02 Enter the mounting valve and option part numbers under the manifold base part number.