to 8E-10 IDU3E-10, 4E-10 500 VA IDF-TR500-2 Output sealing C A Output outlet Input fuse 5A Voltage selector B 220V INPUT 200V 230V 240V E D 4-5.5 x 10 long hole F Input cord 2 m Transformer part no.

Applicable bore size Dd9 L1 L2 m d Drill through Included split pin Included flat washer Clevis Knuckle 2 x d Dd9 CDP-2A 40 10 0.040 0.076 46 38 4 3 3 x 18 L Polished round 10 L1 L2 m L1 L2 m CDP-3A 50 40, 50, 63 12 0.050 0.093 55.5 47.5 4 3 3 x 18 L Polished round 12 2 x d Dd9 CDP-4A 63 16 0.050 0.093 71 61 5 4 4 x 25 L Polished round 16 L1 L2 m CDP-5A 80 18 0.050 0.093 76.5 66.5 5 4

Load weight m (kg) Load weight m (kg) 30 CXW 30 40 50 32 20 CXS 10 20 CXT 5 4 10 MX 3 5 MXU 200 2 3 4 5 20 30 40 50 10 1 100 1 100 10 200 20 30 40 50 2 3 4 5 Eccentric distance l (mm) Eccentric distance l (mm) MXS 75 to 124 stroke 50 to 74 stroke MXQ 100 100 200 63 P=0.5MPa P=0.5MPa MXF 80 50 40 50 100 MXW 40 Load weight m (kg) Load weight m (kg) 30 40 50 32 MXP 20 30 MG 10 20 MGP 5 4 3

Lead wire length symbols: 0.5 mNil (Example) A53 3 m L (Example) A53L 5 m Z (Example) A53Z Auto switches marked with are made-to-order specifications.

The range in the chart below that is delineated by bold solid lines indicates the relation between load weights and maximum driving speeds. 6 8 10 4 Bore size (mm) 0.05 to 0.5 Operating piston speed (m/s) 3.8 x 10-3 6.25 x 10-3 9.35 x 10-3 12.5 x 10-3 Allowable kinetic energy (J) 10 6 8 10 1 Load weight kg 4 0.1 0.01 0.1 1.0 0.01 Maximum speed V (m/s) 22 Series CUJ Specific Product Precautions

-m-m PFA750-m-m Dry air, N2 Heater type 1 to 10l/min (0.04 to 0.35SCFM) 0.1l/min (0.004SCFM) 5 to 50l/min (0.18 to 1.77SCFM) 0.5l/min (0.02SCFM) l/min, CFM x 10-2 Instantaneous flow rate Cumulative flow rate Display units l, ft3 x 10-1 0 to 0.5MPa (0 to 72psi) 1.0MPa (145psi) 3kPa (50l/min) [0.44psi (1.77SCFM)] 0 to 9l (0 to 35,300 ft3) 0 to 50C (32 to 122F) with no condensation 5% F.S.

Without arm Q R M MK MK 20 MK2T 8 19 CK1 17 0.1 0.2 Q (mm) CLK2 Q (mm) Rod state Clamp stroke 10 mm Model Q 10 mm 20 mm Clamp stroke CLKG Rod state Bore size 50 mm 20 mm 30 mm 50 mm Retracted 146.5 175.5 166.5 205.5 186.5 235.5 226.5 295.5 R M Q 82 82 83 83 91.5 91.5 85 85 96.5 96.5 100 100 R 33.5 63 35.5 65 50 85 57.5 92.5 65.5 104.5 65 104 M Q 126.5 126.5 130 130 R 95.5 164.5 95 164 M MK63

Furthermore, if the cable length exceeds 5 m, then it will decrease by up to 10% for every additional 5 m. (At 15 m: Reduced by up to 20%) 12. When checking the conductivity of the cable, be careful not to deform the connectors mating hole and terminals.

M B O L S NAM450-N06D 34 225 106 10 NAM550-N10D 1" 259 122 10 NAM650-N14D 112" 361 160 10 NAM850-N14D 2" 473 220 10 Manual and Autodrain types are same overall dimensions.

F: Angle adjustment range 5 E: Angle adjustment range 5 E: Angle adjustment range 5 B port Angle adjustment screw A port Clockwise rotation 0 8 0 e Allowable Lateral Load to the Piston Rod End gl 10 n a e nt gl e an m st t en u dj m a m st u ju m i in ad M Using friction fittings makes it easier to mount the load to the piston rod end.

Furthermore, it cannot be used as an emergency cutoff valve.

m 0.3 MPa Graph (5) F 0.4 MPa Graph (6) m 0.5 MPa Graph (7) F 9-6-6 7 Model Selection Series MNB Selection Graph Graph (5) Graph (2) 0.3 MPa P < 0.4 MPa 0.3 MPa P < 0.4 MPa 1000 1000 500 400 300 500 400 300 100 100 80 80 200 200 63 63 100 100 50 50 40 40 80 80 100 100 Load weight: m (kg) Load weight: m (kg) CL 63 63 50 40 30 50 40 30 32 32 50 50 40 40 CL1 20 20 32 32 MLGC 10 10 CNG

m 0.3 MPa Graph (5) F 0.4 MPa Graph (6) m 0.5 MPa Graph (7) F 9-6-6 7 Model Selection Series MNB Selection Graph Graph (5) Graph (2) 0.3 MPa P < 0.4 MPa 0.3 MPa P < 0.4 MPa 1000 1000 500 400 300 500 400 300 100 100 80 80 200 200 63 63 100 100 50 50 40 40 80 80 100 100 Load weight: m (kg) Load weight: m (kg) CL 63 63 50 40 30 50 40 30 32 32 50 50 40 40 CL1 20 20 32 32 MLGC 10 10 CNG

D-M9m m: Operating range Size q m: Operating range q d: Hysteresis range 10, 15 170 20 20, 30 100 15 40 86 10 Actuated position: ON Auto switch d: Hysteresis range OFF D-S/T99(V)m, S9P(V), S/T79, S7P, D-97/93A, 90/90A, R73/80m (OFF) Magnet Size q m: Operating range q d: Hysteresis range 10, 15 110 10 20, 30 90 40 52 8 Note) Since the figures in the above table are provided as a guideline

Set the mounting band perpendicularly to cylinder tube. 20 50 63 80 100 25 32 40 D-B7/B80 8 10 9 10 10 11 D-B73C/B80C D-C7/C80 8 10 9 10 10 11 D-C73C/C80C 8 10 9 10 10 11 D-B5/B64 11 11 MX Mounting correctly Mounting incorrectly 13 13 14 14 14 17 D-B59W 18 16 D-G79/K79 8 10 9 10 10 11 Auto Switch Mounting Bracket Part No.

Confirm that the value is within the operating range of the point of application L = 60 mm. 10 10 RZQ 5 5 MI W S CEP1 1 1 kg 1 CE1 CE2 0.25 kg ML2B 10 20 40 5 10 20 30 C J G5-S 32.5 m/min Transfer speed (m/min) Transfer speed (m/min) 12 m/min CV Procedure 3: Confirmation of allowable lateral load MVGQ MIW12 MIS12 1.

Confirm that the value is within the operating range of the point of application L = 60 mm. 10 10 RZQ 5 5 MI W S CEP1 1 1 kg 1 CE1 CE2 0.25 kg ML2B 10 20 40 5 10 20 30 C J G5-S 32.5 m/min Transfer speed (m/min) Transfer speed (m/min) 12 m/min CV Procedure 3: Confirmation of allowable lateral load MVGQ MIW12 MIS12 1.

V 10 T = t x = 7.7 x = 77 (s). V 10 T = t x = 2.4 x = 24 (s). V 10 10 10 100 10 100 10 1012 Booster Regulator VBA Series VBA43A VBA11A Pulsation/Pulsation is decreased with a tank. If the outlet capacity is undersized, pulsation may occur.

Reference formulae [Dynamic moment at impact] Use the following formulas to calculate dynamic moment when taking stopper impact into consideration. m : Load mass (kg) F : Load (N) FE: Load at acceleration and deceleration (N) a : Set acceleration (m/s2) : Set speed (mm/s) M : Static moment (Nm) FE = m a Nominal size Maximum load weight (kg) 16 5 25 10 L1 : Distance to the loads center of