3 12 20 16 35 22 9 M5 8 3 12 20 16 40 26 9 M5 10 5.5 12 22 26 45 32.5 9.5 M6 12 5.5 15 25 28 51 38 12 M6 12 6.5 15 27 32 64 46.5 12 M8 16 6.5 20 32 40 74 56.5 16 M8 8 Series C55 Proper Auto Switch Mounting Position (Detection at Stroke End) and Its Mounting Height Reed switch Solid state switch D-A9 D-M9 D-F9BAL D-F9 W B Hs W A 20, 25 Hs B A W 32, 40, 50, 63 Courtesy of Steven Engineering
However, this inrush current will decrease shortly after. * When the product uses multiple heater assemblies, do not turn on the power to each heater assembly at the same time. Turn on the power to each heater assembly one-by-one at intervals of 30 sec. since the inrush current is large. * The heater temperature will decrease several % from the start of heating and then becomes stable.
1 Low Profile Single Axis Electric Actuator Series LG1H Series LG1H High Rigidity Direct Acting Guide Without coupling With coupling LJ1 LG1 LC1 LX LC6D/LC6C Switches Lead screw lead mm Mounting orientation Page Model Motor/Screw connection Series Motor type Guide type Ground ball screw Rolled ball screw Slide screw 10 20 10 20 20 20 20 LG1H20 LG1H21 LG1H21 Without coupling 148 Standard motor
02-07PA 1/4" 11.2 23.4 32.7 (32.8) 20 (20) AS22m1F-02-09PA 5/16" 13.2 23.9 33.2 (33.3) 14.2 20 (21) AS22m1F-02-11PA 3/8" 15.5 26.4 35.7 (35.8) 15.6 21 (22) AS32m1F-03-07PA 1/4" 3/8 21 (21.7) 7.2 20.9 30.2 (30.3) 1/4 17 (17.5) 22.6 36.6 35 29 (28.5) 27.4 (26.9) 13 13.3 38 (39) AS32m1F-03-09PA 5/16" 13.2 22.7 33.9 (34.3) 14.2 38 (40) AS32m1F-03-11PA 3/8" 15.5 26.7 37.9 (38.3) 28.2 15.6 39 (
3 to @4 are at room temperature (20 to 25C). Type of Impact Load Free fall impact Check Model Selection Step z to c prior to use. Graph !3/RJ06 Graph !5/RJ10 Graph !
(at 100l/min) 10kPa (at 200l/min) 30kPa (at 500l/min) Pressure loss Operating temperature range 0 to 50C (with no condensation) Linearity Note 1) 20% F.S. or less 25% F.S. or less Repeatability 1% F.S. or less Note 2) 1% F.S. or less Temperature characteristics 2% F.S. or less (15 to 35C) 3% F.S. or less (0 to 50C) Power supply voltage 12 to 24VDC (ripple 10% or less) Current consumption
The bore size is 25, so the allowable load by thrust will be 20 kg. Work load is 5.5 kg < 20 kg. OK The load is restricted to 20 kg when the stroke is 600 mm and Z = 100 mm taken from Graph (5) z (Refer to page 1495). (2) Allowable load by stroke Work load is 5.5 kg < 20 kg.
Applicable bore size d H B C D E1 C H NX B A L1 A1 U1 I-04A 40 69 22 24 55 M14 x 1.5 15.5 20 12+0.070 0 16 0.1 0.3 I-05A 50, 63 74 27 28 60 M18 x 1.5 15.5 20 12+0.070 0 16 0.1 0.3 I-08A 80 91 37 36 71 M22 x 1.5 22.5 26 18+0.070 0 28 0.1 0.3 I-10A 100 105 37 40 83 M26 x 1.5 24.5 28 20+0.084 0 30 0.1 0.3 NT-04 40 M14 x 1.5 8 22 25.4 21 NT-05 50, 63 M18 x 1.5 11 27 31.2 26 NT-08 80 M22 x 1.5
is at least 10 to 20 times the workpiece weight.
Rc 1/8 20 40.5 70 73 162 25 58 241 14 104 26 55 M8 x 1.25 Rc 1/4 Bracket Mounting Stroke Long Stroke Without Rear Plate Bracket mounting stroke Stroke range (mm) Bore size (mm) Bore size (mm) Bore size (mm) Y R Z 20 25 32 40 50 20 25 32 40 50 20 25 32 40 50 100 st or more 250 to 400 88 14 119 125 st or more 350 to 500 88 14 131 150 st or more 350 to 600 90 14 136 200 st or more 350 to 800
) 148 40 185 163 Air Air Dustproof filter Model no. label NRTL label 90 20 20 110 Rubber legs (4 pcs.)
(Max. 20 stations) SUP/EXH block assembly mounting position Valve stations Series 3 5 7 02 2 stations SY3000 SY5000 SY7000 20 20 stations Symbol Mounting position U side D side Both sides Special specifications Applicable stations U D B M 2 to 10 stations 2 to 20 stations In case of special specifications, indicate separately on a manifold specification sheet.
Mount a switch at the center of the operating range. Adjust the mounting position of an auto switch so that the piston stops at the center of the operating range (the range in which a switch is ON). (The mounting positions shown in the catalog indicate the optimum positions at stroke end.)
Blow Velocity Distribution (Supply Pressure: 0.3 MPa) qEnergy saving static neutralization nozzle IZN10E-01 wHigh flow rate nozzle IZN10E-02 0 0 100 100 Distance [mm] Distance [mm] 200 200 4 m/s 14 m/s 300 300 11 m/s 3 m/s 400 400 8 m/s 2 m/s 500 30 30 20 10 0 10 20 500 30 30 20 10 0 10 20 Distance (Horizontal) [mm] Distance (Horizontal) [mm] 8 IZN10E Series Flow Rate Characteristics qEnergy
above [Test condition ISO 8573-4:2001, Test method ISO 12500-3:2009 compliant] ** Flow capacity, inlet pressure, and the amount of solid bodies at the filter inlet are stable. ** New element *4 Water droplet elimination rate for the conditions below in addition to the rated conditions above [Test method ISO 12500-4:2009 compliant] ** Water droplet at filter inlet = 33 ml/m3 (ANR) (Water
kg] 0 10 20 30 40 50 60 Work load [kg] 1500 1500 1500 Mep 1000 1000 1000 L3 [mm] L3 [mm] L3 [mm] m L3 Z 500 500 500 0 0 0 0 10 20 30 40 50 60 Work load [kg] 0 5 10 15 20 Work load [kg] 0 10 20 30 40 Work load [kg] 1500 1500 1500 L4 1000 1000 1000 L4 [mm] L4 [mm] L4 [mm] X 500 500 500 0 0 0 0 5 10 15 20 Work load [kg] 0 10 20 30 40 Work load [kg] 0 10 20 30 40 50 60 Work load [kg] 1500 1500
LVN Types 10, 20 Stainless steel VVDW 2 0 5A TI/ TIL Series PA 1 2 10 20 PAX PB Type 30 VVCW20-5A 17-2-73 14 For details about certified products conforming to international standards, visit us at www.smcworld.com.