(Refer to p.12 for (Refer to P.12 for vertical operation.) Refer to P.11 for date A. Refer to P.12 for date B.
1 IO-Link master Number of ports and connector Symbol Number of ports Connector Port specifications B 4 ports M12 connector Symbol Content A Port Class A B Port Class B Summary of Product parts EX600-L#B1 No.
AL.01 Contact output 3 function ALM Contact output 3 operation B Selected for contact output 3 AL.01 Option T [High pump head] 0.70MPa102PSI,MT:0.60MPa(87PSI) 5.2 Function HRS Series 5-6 HRX-OM-R016 Chapter 5 Display and setting of various functions 5.3 Main screen 5.3.1 Main screen Displays the current temperature and the set temperature of the circulating fluid.
C) EX600-DX#B/C (4 byte) Byte Bit Parameter Setting value 0..3 Unit No. 0..8 0 4..7 Parameter type 1 1 0..7 Unit ID EX600-DX#B: 01 (Hex) EX600-DX#C: 03 (Hex) Unit parameter 0 Monitor short circuit (power) 0: disable, 1: enable 1 Reserved 0 2 Inrush current filter 0: disable, 1: enable 3 Reserved 0 2 4..5 Input filtering time 0: 0.1 ms, 1: 1 ms, 2: 10 ms, 3: 20 ms 6..7 Input extension time
OFF state { A R1 (Exhaust air) P B (Supply air) F1 < F2 condition: See figure q. ON state { { Immediately after turning on F1 > F2: See figure e.
AL.01 Contact output 3 function ALM Contact output 3 operation B Selected for contact output 3 AL.01 5.2 Function HRS Series 5-6 HRX-OM-R005 Chapter 5 Display and setting of various functions 5.3 Main screen 5.3.1 Main screen Displays the current temperature and the set temperature of the circulating fluid.
2 (A) 4 (B) 2 VQC4101 VQC4100 VQC4101 VQC4100 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) e q w e q w (A) 4 (B) 2 (A) 4 (B) 2 VQC4200 VQC4201 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) e q w r e q w r (A) 4 (B) 2 (A) 4 (B) 2 VQC4300 VQC4301 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) (A) 4 (B) 2 (A) 4 (B) 2 VQC4400 VQC4401 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) (A) 4 (B) 2 (A) 4 (B) 2 VQC4500 VQC4501
2 (A) 4 (B) 2 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) q w e q w VQ5201 VQ5200 (A) 4 (B) 2 (A) 4 (B) 2 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) e e r q w r q w VQ5301 VQ5401 VQ5300 VQ5400 (A) 4 (B) 2 (A) 4 (B) 2 (A) 4 (B) 2 (A) 4 (B) 2 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) VQ5500 (A) 4 (B) 2 VQ5501 (A) 4 (B) 2 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2
Direct Operated Solenoid Valve Metal Seal Series VS4 10 Model Flow characteristics Max. (1) operating cycle (cpm) (3) VK Response (2) time (ms) Weight (kg) Model Port size Rc (Nominal size) Number of positions JIS Symbol P A/B A/B EA/EB VZ C [dm 3/(sbar)] C [dm 3/(sbar)] b b Cv Cv AC DC AC DC AC DC VS4110-01 (6A) 3.2 3.2 0.42 0.37 0.86 0.80 1 8 2 (Single) 1,200 180 13 or less 45 or less
K Hexagon width across flats 12 Hexagon width across flats 12 ZU ZL ZY ZQ ZF ZP ZCU AMJ Bellows Bellows A D E F N P A E F N P B B Y Y C C D Misc.
2 (A) 4 (B) 2 VQ5 VQZ 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) VQD q w e q w VQ5251 (A) 4 (B) 2 VQ5250 (A) 4 (B) 2 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) e r q w r q w e VQ5350 VQ5450 VQ5351 VQ5451 (A) 4 (B) 2 (A) 4 (B) 2 (A) 4 (B) 2 (A) 4 (B) 2 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) VQ5550 VQ5551 (A) 4 (B) 2 (A) 4 (B) 2 1 (P) 5 (R1) 3 (R2) 1 (P)
106 46.8 59.2 9 9 U side 83.5 55.5 M5 ground screw 19 34.5 n 12 X 2n-Rc 3/8, 1/2 4(A), 2(B) port B 2 A 4 6 Indicator light B 2 A 4 A B 5 SMC SMC SMC SMC SMC A B B B B B B 2 A 4 Manual override A B 4 A L2 L1 58.5 P = 41 B 2 A 4 A B 3 A B 2 A 4 A B 2 A 34.5 48 68.5 P = 41 B 2 A 4 A 1 A X 12 Stations R4.5 15.5 17 22 51 69 117 D side 107.8 179 (Single, Double, 3 position, Rubber type) 184.5
M M A L1 H/DL L/LL D1 D2 L2 KC H Connection threads KK Male Branch: KPQU, KPGU (M5) KK130 Effective area mm2 D Model L TPH TPS A (M5) 2 x Applicable tubing Connection thread R M H (width across flats) Note1) Applicable tubing O.D. mm Weight g P M P DM D M5 x 0.8 1/8 1/4 M5 x 0.8 1/8 1/4 1/8 1/4 1/4 3/8 3/8 1/2 KPGU04-M5 KPGU04-01 KPGU04-02 KPGU06-M5 KPGU06-01 KPGU06-02 KPGU08-01 KPGU08-02
Note 3) Value for quick response type Symbol 2 position single 3 position closed center 3 position exhaust center 3 position pressure center 2 position double (Double solenoid) 2(B) (A)4 2(B) (A)4 2(B) (A)4 2(B) (A)4 2(B) (A)4 (R1)5 1 (P) 3(R2) (R1)5 1 (P) 3(R2) (R1)5 1 (P) 3(R2) (R1)5 1 (P) 3(R2) (R1)5 1 (P) 3(R2) Manifold Specifications Piping specifications Note 4) 1 station weight (g)
Memory map of input data Data (2 byte) Input area Branch connector (INPUT) MSB LSB MSB LSB 15 8 7 0 byte (b+1) byte (b) Word (a) COM A byte (b+3) byte (b+2) Word (a+1) COM B byte (b+5) byte (b+4) Word (a+2) COM C byte (b+7) byte (b+6) Word (a+3) COM D byte (b+9) byte (b+8) Word (a+4) GW unit status information byte (b+10) byte (b+11) Word (a+5) (a, b=0 to) : Only when the GW unit status
Note 4) Values for the low wattage (0.5 W) specifications. 2 position double (Double solenoid) (A) 4 (B) 2 (A) 4 (B) 2 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) Metal seal Rubber seal 3 position closed center 4 position dual 3 port valve (B) 3 position pressure center (A) 4 (B) 2 (A) 4 (B) 2 4 2 5 3 1 1 (P) 5 (R1) 3 (R2) N.O.
Memory map of input data Data (2 byte) Input area Branch connector (INPUT) MSB LSB MSB LSB 15 8 7 0 byte (b+1) byte (b) Word (a) COM A byte (b+3) byte (b+2) Word (a+1) COM B byte (b+5) byte (b+4) Word (a+2) COM C byte (b+7) byte (b+6) Word (a+3) COM D (a, b=0 to) Memory map of output data Data (2 byte) Output area Branch connector (OUTPUT) MSB LSB MSB LSB 15 8 7 0 byte (d+1) byte (b) Word
(Only for EX510-S 01 ) -28No.EX-OMI0001-I No.
Body size Port size Port M5 01 Nil M5 01 1(P), 2(A), 3(R) M5 IR-A A Body ported 8 1 Without sub-plate M5 IR Base mounted B Position for port P1 8 1 IRV 3 VEX1 3 10 G 5 VEX VEX SRH Regulator valve Option Bracket Foot Pressure gauge Silencer for bleed port Dimensions of port P1