Rated Pressure Range: -0.1 to 2 MPa, Piping: Rc1/8, Rear Ported, Input/Output: NPN Open Collector 2 Outputs, Option 1: Fixed SI Unit, Option 2: -, Option 3: -, X Options: -
Rated Pressure Range: -0.1 to 2 MPa, Piping: Rc1/8, Rear Ported, Input/Output: PNP Open Collector 2 Outputs, Option 1: Fixed SI Unit, Option 2: -, Option 3: -, X Options: -
Rated Pressure Range: -0.1 to 2 MPa, Piping: Rc1/8, Rear Ported, Input/Output: PNP Open Collector 1 Output, Option 1: Fixed SI Unit, Option 2: -, Option 3: -, X Options: -
Rated Pressure Range: -0.1 to 2 MPa, Piping: Rc1/8, Rear Ported, Input/Output: NPN Open Collector 2 Outputs, Analog Current Output, Auto-Shift, Option 1: Fixed SI Unit, Option 2: -, Option 3: -, X Options: -
Rated Pressure Range: -0.1 to 2 MPa, Piping: Rc1/8, Rear Ported, Input/Output: NPN Open Collector 2 Outputs, Analog Voltage Output, Auto-Shift, Option 1: Fixed SI Unit, Option 2: -, Option 3: -, X Options: -
Rated Pressure Range: -0.1 to 2 MPa, Piping: Rc1/8, Rear Ported, Input/Output: PNP Open Collector 2 Outputs, Analog Current Output, Auto-Shift, Option 1: Fixed SI Unit, Option 2: -, Option 3: -, X Options: -
Rated Pressure Range: -0.1 to 1 MPa, Piping: Rc1/8, Rear Ported, Input/Output: NPN Open Collector 1 Output, Option 1: Fixed SI Unit, Option 2: -, Option 3: -, X Options: -
Rated Pressure Range: -100 to 100 kPa, Piping: Rc1/8, Rear Ported, Input/Output: PNP Open Collector 1 Output, Option 1: Fixed SI Unit, Option 2: -, Option 3: -, X Options: -
Rated Pressure Range: 1 to -101 kPa, Piping: Rc1/8, Rear Ported, Input/Output: NPN Open Collector 2 Outputs, Option 1: Fixed SI Unit, Option 2: -, Option 3: -, X Options: -
Rated Pressure Range: 1 to -101 kPa, Piping: Rc1/8, Rear Ported, Input/Output: PNP Open Collector 2 Outputs, Option 1: Fixed SI Unit, Option 2: -, Option 3: -, X Options: -
Rated Pressure Range: 1 to -101 kPa, Piping: Rc1/8, Rear Ported, Input/Output: NPN Open Collector 1 Output, Option 1: Fixed SI Unit, Option 2: -, Option 3: -, X Options: -
Rated Pressure Range: 1 to -101 kPa, Piping: Rc1/8, Rear Ported, Input/Output: PNP Open Collector 1 Output, Option 1: Fixed SI Unit, Option 2: -, Option 3: -, X Options: -
Rated Pressure Range: 1 to -101 kPa, Piping: Rc1/8, Rear Ported, Input/Output: NPN Open Collector 2 Outputs, Analog Voltage Output, Auto-Shift, Option 1: Fixed SI Unit, Option 2: -, Option 3: -, X Options: -
Rated Pressure Range: 1 to -101 kPa, Piping: Rc1/8, Rear Ported, Input/Output: NPN Open Collector 2 Outputs, Analog Current Output, Auto-Shift, Option 1: Fixed SI Unit, Option 2: -, Option 3: -, X Options: -
Rated Pressure Range: 1 to -101 kPa, Piping: Rc1/8, Rear Ported, Input/Output: PNP Open Collector 2 Outputs, Analog Current Output, Auto-Shift, Option 1: Fixed SI Unit, Option 2: -, Option 3: -, X Options: -
Rated Pressure Range: -100 to 100 kPa, Piping: Rc1/8, Rear Ported, Input/Output: NPN Open Collector 2 Outputs, Analog Voltage Output, Auto-Shift, Option 1: Fixed SI Unit, Option 2: -, Option 3: -, X Options: -
I O N S F O R M A K I N G A N D M O U N T I N G A R M S D I M E N S I O N S H E A D S I D E F L A N G E 32, 40, 50, 63 S E R I E S MK2 W H E N A R M S A R E T O B E M A D E S E P A R AT E LY, T H E I R L E N G T H A N D W E I G H T S H O U L D B E W I T H I N T H E F O L L O W I N G R A N G E.
P O R T S PT Ports XC18 NPT Ports (25~40 Only) A L L O W A B L E M O M E N T A N D M A X I M U M A L L O W A B L E L O A D H O W T O O R D E R M Y 1 M R O D L E S S C Y L I N D E R MY1M G M O M E N T (N M) A L L O W A B L E L O A D (N) B O R E S I Z E 16 16mm 20 20mm 25 25mm 32 32mm 40 40mm 50 50mm 63 63mm Local Production Available N O O F S W I T C H E S ...2 Pieces S ...1 Piece
Connector for unit (Plug) 6 y t y t EX600-DXB EX600-DYB EX600-DXC q w q w e q w er e y t y t y t EX600-DXD EX600-DXE EX600-DYE EX600-DME EX600-DXF EX600-DYF EX600-DMF Analog Unit q w e q w e No.
e q IN OUT t Modular F.R.L. e q r IN OUT w r w AC-A AC-B AR30(K)-B/AR40(K)-B q t AR50(K)-B/AR60(K)-B e IN OUT q t r w e IN OUT r w Component Parts No.