With cable (3 m) With cable (5 m) With cable (1.5 m) With cable (3 m) With cable (5 m) With cable (1.5 m) With cable (3 m) With cable (5 m) Max. 16 stations Kit P Kit P Kit J Kit J Kit F Kit F L S The valve is equipped with an indicator light/surge voltage suppressor, and the voltage is 24 VDC. kit (Serial transmission unit) kit (Lead wire cable) The dust-protected type SI unit is applicable
M2 W1 CC W3 : Collision speed (mm/s) L1 : Distance to the center of load gravity (m) ME : Dynamic moment (Nm) g : Gravitational acceleration (9.8 m/s2) YES m : Load weight (kg) F : Load (N) FE : Load equivalent to impact (at impact with stopper) (N) a : Average speed (mm/s) Pitch moment Yaw moment NO M1 = W4 x L3 M2 = W1 x L2 RB M1e = We x L3 x 1 3 M3e = We x L2 x 1 3 NO Do not use it
6 Voltage 1 to 6 L M 2 3 (VQ0) (VQ1000) (VQ2000) L M 2 3 (VQ0) (VQ1000) (VQ2000) VQ110L VQ110L Double (latching) Double (latching) Voltage 1 to 6 Voltage 1 to 6 The direction of the L and M connectors of a pilot valve is opposite to that of the single and double styles.
Dimensions LLAA--C Stations 4-Mounting hole for W Y Dimensions (mm) A S K Model LLA2A LLA3A LLA4A LLA5A 11.5 L1 24 L2 L3 29 Sensor (Breathing port) U 2-R 34.5 (mm) H G Station 2 3 4 5 Model C Symbol P N L1 L2 L3 L1 L2 L3 L1 L2 L3 L1 L2 L3 62 93 124 155 E V LLA2A 75 106 137 168 Pitch = B A (OUT) port n-Q 118 149 180 211 P (IN) port 2-Q 74 111 148 185 (Max.
output Unit specifications Nil M P None Option 1 Nil With unit conversion function Note 1) Fixed SI unit Note 2) Lead wire with connector (Length: 2 m) Pressure unit: psi (Initial value), with unit conversion function Note 1) Note 1) Under the New Measurement Law, sales of switches with the unit switching function have not been allowed for use in Japan.
, ISE70/75 1/4" PT VERSION, INSTRUMENTATION, ISE70/75 PRESSURE SWITCH, DA, ISE70/75 1/4" PT VERSION, 0.46297 lb
M plug connector 2 position double: VZS2250-M(Z)-01 3 position closed center: VZS2350-M(Z)-01 3 position exhaust center: VZS2450-M(Z)-01 3 position pressure center: VZS2550-M(Z)-01 DIN terminal 2 position double: VZS2250-D(Z)-01 3 position closed center: VZS2350-D(Z)-01 3 position exhaust center: VZS2450-D(Z)-01 3 position pressure center: VZS2550-D(Z)-01 Applicable cable O.D.: 3.5 to 7 MAX
H -M5 M5 x 0.8 (A port) 14 5 10 2-3.2 (For mounting) 26.4 17 3 2.5 Manual override A 11 G: Approx. 300 H: Approx. 600 (Lead wire length) 48.6 [50.8] (Light/surge voltage suppressor) 41.5 [48.5] + M5 x 0.8 (X port) 35.6 28.5 26.1 X R P 13 5 5 10 M5 x 0.8 (P, R port) 10 8.6 7.5 17.5 23 L plug connector (L): SYJ34-L-M5 M plug connector (M): SYJ34-M-M5 M8 connector (W0): SYJ34-W0-M5 Approx.
Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Solid state switches marked with are produced upon receipt of order. Since there are other applicable auto switches than listed above, refer to the Best Pneumatics No. 2 for details.
32-07A 9.6 9.4 26.5 25.4 23.5 22.4 13.3 6 11.5 Note 1) Reference dimensions Note 2) Reference dimensions of threads after installation 673 AS-FG Series For R, NPT thread Dimensions/ Elbow type Seal method: Sealant For R, NPT thread D3 Applicable tubing O.D. d D1 A L4 L3 M T L1 H (Width across flats) L2 Metric Size [mm] Model d T H D1 D3 L1 L2 L3 L4 Note 1) A Note 1) M Weight [g] Unlocked
Type Seal method: Sealant For R, NPT thread Indicator window direction: 0 Indicator window direction: 180 D3 W1 W2 X Y Applicable tubing O.D. d A L4 D1 L3 M L2 L1 T H (Width across flats) Metric Size [mm] Model d T (R, NPT) H D1 D3 L1 L2 L3 L4 Note 1) A Note 2) M W1 W2 X Y Weight [g] Unlocked Locked Unlocked Locked AS221FS-01-23 (S) 3.2 7.2 13 (13) AS221FS-01-04 (S) 4 8.2 AS221FS-01-06 (
8 693 AS-FSG Series Dimensions: Elbow Type Seal method: Sealant For R, NPT thread Indicator window direction: 0 Indicator window direction: 180 D3 W1 W2 X Y Applicable tubing O.D. d A L4 D1 L3 M L2 L1 T H (Width across flats) Metric Size [mm] Model d T (R, NPT) H D1 D3 L1 L2 L3 L4 Note 1) A Note 2) M W1 W2 X Y Weight [g] Unlocked Locked Unlocked Locked AS221FSG-01-23 (S) 3.2 7.2 13 (13)
CY1F CY1F M1E m x g FE CYP M3E = 1/3 x FE x L2 (FE = 1.4/100 x a x g x m) = 0.05 x a x m x L2 = 0.05 x 300 x 0.5 x 0.04 = 0.3 [Nm] 3B = M3E/M3E max = 0.3/1.07 = 0.28 Investigate M3E. a From above, find the value of M3E max at 420 mm/s in Graph (3). M3 M3E m x g FE L2 DFrom above, n = 1 + 2 + 3A + 3B = 0.1 + 0.082 + 0.35 + 0.28 = 0.812 From n = 0.812 1, it is applicable.
) L1 = 50 [mm] L2 = 40 [mm] m L2 L1 Item Load factor an Note 1.
) L1 = 50 [mm] L2 = 40 [mm] m L2 L1 Item Load factor an Note 1.
of arm section) L1 = 50 [mm] L2 = 40 [mm] a m L2 Item Load factor n Note zLoad mass 1 = m/mmax = 0.5/5 = 0.1 Investigate m.
x C2, C4, N1, N3 <1(P), 5(EA), 3(EB) port> C2: 2 One-touch fitting C4: 4 One-touch fitting N1: 1/8" One-touch fitting N3: 5/32" One-touch fitting 16.7 With plug connector/light, built-in silencer S0736S-mM(O)-m External Pilot 2-Position Single Grommet (G): S0716R-mG-m-m 2-Position Double/3-Position Closed Center Grommet (G): S07 6R-mG-m-m 2 3 (Lead wire length) (Lead wire length) 300 300
281 292 325 336 7 278 289 314 325 322 333 366 377 4 173 184 209 220 199 210 243 254 5 208 219 244 255 240 251 284 295 2 103 114 139 150 117 128 161 172 3 138 149 174 185 158 169 202 213 L1 Side ported L2 VV2CA3 L1 Front ported L2 L1 Side ported L2 VV2CA4 L1 Front ported L2 (mm) Dimensions Electrical entry B C E F G H J1 J2 J3 K L M N A Grommet: G Conduit: C DIN terminal: D Conduit terminal