SMC Corporation of America
Elite Part Number Search
Search Results "IZS42-460-06B"

ALB 8 3 8 3 1 Fluid Proof pressure Max. operating pressure Air 1.5 MPa LMU 0.7 MPa 1.0 MPa ALIP Operating pressure differential range (Difference between tank pressure and line pressure) (Note 1) 0.1 to 0.6 MPa AEP HEP Vibration resistance (Pressure differential 0.3 MPa) 1 G (9.81 m/sec2) or less 120 : 65 : 100 : 120 190 220 1800 4 1 (Note 2) 4 1 Min. operating flow (L/min (ANR)) 8 3 1 : 460

Flow Rate and Effective Area AS3001F AS2051F AS4001F AS2001F AS1001F Model Metric size 3.2, 4, 6 4 6 6 8 6 8 10, 12 10 12 Tubing O.D. 1/8", 5/32" 3/16", 1/4" 5/32" 3/16", 1/4" 3/16" 1/4", 5/16" 1/4" 5/16" 3/8" 3/8" 1/2" Inch size Controlled flow (Free flow) 100 130 230 290 460 420 660 920 1050 1390 Air flow /min (ANR) 1.5 2 3.5 4.5 7 6.5 10 14 16 21 Effective area (mm 2) Note) Flow rate values

Flow Rate and Effective Area Flow Direction Symbol on Body AS1002F 3.2, 4, 6 1/8", 5/32" 1/4" 100 1.5 AS2002F 4 AS3002F AS2052F AS4002F 12 Series Metric size 2 6 8 1/4" 5/16" 460 7 6 10 8 10, 12 6 JIS symbol Inch size Tube O.D. 5/16" 5/32" 1/4" 1/4" 3/8" 3/8" 1/2" Flow rate (l/min (ANR)) 660 10 290 4.5 390 6 920 14 920 14 1390 21 20 0.3 130 2 230 3.5 Controlled flow (Free flow) Effective

Min. operating pressure 5 to 60C (No freezing) 10 turns 10 turns 8 turns Ambient and fluid temperature Number of needle rotation Hexagonal lock nut With seal, Hexagonal lock nut, Nickel plated Option 181 106 64 29 10 6 3 Weight (g) 20 0.3 1700 26 920 14 460 7 230 3.5 105 1.6 Flow rate /min (ANR) Controlled flow (Free flow) Effective area (mm2) Note 1) Flow rate values are measured at 0.5

1F-M3 AS12 1F-M5 AS13 1F-M5 AS22 1F-01 AS23 1F-01 AS22 1F-02 AS23 1F-02 AS32 1F AS33 1F AS42 1F AS43 1F Model Metric size 3.2, 4 3.2, 4, 6 3.2, 4 6, 8, 10 8,10 4 6 6 8 10 12 10, 12 Tubing O.D. 1/8" 5/32" 1/8", 3/16" 1/8" 5/32" 3/16", 1/4" 5/16" 1/4", 5/16" 3/8" Inch size 5/32" 3/16" 5/16" 3/8" 1/2" 3/8" 1/4" 1/4", 5/32" Controlled flow (Free flow) Flow rate /min (ANR) 20 100 180 230 260 390 460

Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: Rc, Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)]

Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)]

Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option: M (Applicable to Deionized Water Piping)

Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)]

Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: F [G (w/Rc-G Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)]

Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: F [G (w/Rc-G Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)]

Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option: J (w/Automatic Fluid Fill Function)

Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option: J (w/Automatic Fluid Fill Function)

Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option: M (Applicable to Deionized Water Piping)

Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option: W (SI Unit Only)

Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option: W (SI Unit Only)

Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: Rc, Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)]

Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: F [G (w/Rc-G Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option: JM (J + M)

IP65 enclosure, Conforms to UL94V-0 flame resistance, Special construction improves service life when compared with current shading coil, Power consumption: size 1 - 4.5w; size 2 - 7w; size 3 - 10.5w, Body material: C37 (brass), stainless steel, DIRECT OPERATED 2 PORT VALVE (N.C.), 2 PORT VALVE, 460 lb

IP65 enclosure, Conforms to UL94V-0 flame resistance, Special construction improves service life when compared with current shading coil, Power consumption: size 1 - 4.5w; size 2 - 7w; size 3 - 10.5w, Body material: C37 (brass), stainless steel, DIRECT OPERATED 2 PORT VALVE (N.C.), 2 PORT VALVE, 460 lb