Stations: 03 (3 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 5 (Remote Sensor Unit), Return Unit Flow Range: 04 (0.5 to 4 L/min), Return Unit Components: P (w/o Flow Adj.
Stations: 03 (3 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Flow Switch Type: 7 (Integrated Display), Rated Flow Range: 20 (2 to 16 L/min), Return Unit Components: P (w/o Flow Adj.
Stations: 03 (3 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: Flow Adj. Valve: None; Stop Valve: None, Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 04 (0.5 to 4 L/min), Return Unit Components: Flow Adj.
Valve; Stop Valve: None), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: 2T (Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None; Temp.: Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector)
Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN Phone: 03-5207-8249 Fax: 03-5298-5362 https://www.smcworld.com 2019 SMC Corporation All Rights Reserved Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. 1st printing AA printing AA 0AA Printed in Japan. D-G
HEAD OFFICE: 1-16-4, SHIMBASHI, MINATO-KU, TOKYO 105, JAPAN TELEPHONE: 03-3502-2740 FACSIMILE: 03-3508-2480 ECC-PNAL-SOFT-B Effective June 1999 Specifications are subject to change without notice.
Ltd. 1-16-4 Shimbashi, Minato-ku, Tokyo 105-0004, JAPAN Tel: 03-3502-2740 Fax: 03-3508-2480 URL http://www.smcworld.com 2001 SMC CORPORATION All Rights Reserved 1st printing August, 2001 D-SMC.L.A. P-90 (YG) All specifications in this catalog are subject to change without notice. Printed in Japan. This catalog is printed on recycled paper with concern for the global environment.
Stations: 03 (3 Stations), Supply/Return Unit Layout: D (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: P (w/o Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 04 (0.5 to 4 L/min), Return Unit Components: Flow Adj.
Stations: 03 (3 Stations), Supply/Return Unit Layout: U (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: P (w/o Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 04 (0.5 to 4 L/min), Return Unit Components: Flow Adj.
Free flow Controlled flow Model Applicable cylinder bore size (mm) Effective area (mm2) Weight (g) Port size Flow rate (/min (ANR)) Flow rate (/min (ANR)) Flow rate (/min (ANR)) AS2000E-01 AS2000E-02 AS3000E-02 AS3000E-03 AS4000E-02 AS4000E-03 AS4000E-04 90 1/8 1/4 1/4 3/8 1/4 3/8 1/2 340 5.2 250 3.8 20, 25, 32, 40 115 32, 40, 50, 63 810 12.3 810 12.3 130 40, 50, 63 80, 100 1670 25.5 1670
dm3/(sbar) 2.3 Critical pressure ratio 0.35 Flow rate (L/min (ANR)) 810 Controlled flow Sonic conductance dm3/(sbar) 2.3 Critical pressure ratio 0.2 How to Order 02 AS3500 Thread type Rc NPT G Material for handle Resin Metal Nil 2 Nil N F Port size 1/4 3/8 02 03 Metal handle Resin handle Needle Valve/ Flow Rate Characteristics Note) The flow rate characteristics are representative values
Bore size (mm) Bore size (mm) AS2000-01/02 AS600-10 Piping bore Piping bore Cylinder driving speed (mm/s) Cylinder driving speed (mm/s) No load No load No load No load Load ratio Load ratio Bore size (mm) Bore size (mm) AS4000-02/03/04 AS3000-02/03 Piping bore Piping bore Cylinder driving speed (mm/s) Cylinder driving speed (mm/s) Circuit diagram No load No load No load No load Load ratio
3 Port Air Operated Valve VPA3145/3165/3185 Series How to Order 04 4 5 1 VPA3 Thread type VPA Air operated valve Nil Rc G NPT NPTF F N T Port size (IN, OUT port) Number of pilot 1 Single Symbol Port size Rc size VPA3145 VPA3165 VPA3185 Body size 03 04 (10A) 3 8 (15A) 1 2 (20A) 3 4 (25A) 1 1 4 6 1 2 06 10 12 14 20 8 1 2 1 Valve option Nil For ordinary pressure For vacuum and low pressure
-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com AS2000-01/02 AS600-10 Piping bore Piping bore Cylinder driving speed (mm/s) Cylinder driving speed (mm/s) No load No load Load ratio Load ratio Bore size (mm) Bore size (mm) AS4000-02/03/04 AS3000-02/03 Piping bore Piping bore Cylinder driving speed (mm/s) Cylinder driving speed (mm/s) Circuit diagram No load No load Load
Needle Valve/Flow Characteristics AS3500 Inlet pressure: 0.5 MPa Flow rate (/min (ANR)) Effective area (mm2) Metal handle Resin handle Number of needle rotations JIS Symbol How to Order 02 AS3500 Thread type Material for handle Nil N F Resin Metal Nil 2 Rc NPT G Port size 1/4 3/8 02 03 Caution Be sure to read before handling.
Needle Valve/Flow Characteristics AS3500 Inlet pressure: 0.5 MPa Flow rate (/min (ANR)) Effective area (mm2) Metal handle Resin handle Number of needle rotations JIS Symbol How to Order 02 AS3500 Thread type Material for handle Nil N F Resin Metal Nil 2 Rc NPT G Port size 1/4 3/8 02 03 Caution Be sure to read before handling.
Conditions: Operating pressure 0.5MPa, Operating oil Turbine oil Class 1 (ISO VG32), Piping length 1m AS420-02, 03, 04 AS500-06 AS2000-01, 02 AS600-10 AS3000-02, 03 AS4000-02, 03, 04 Circuit 4.12-12
HAl Accessories (Options) HAA7 AT Auto drain Applicable Model HAA7 HAA15 HAA22 HAA37 HAA7-F AD402-03 HAA7-S HAA15-F AD402-03 HAA15-S HAA22-F AD402-03 HAA22-S HAA37-F AD402-04 IDl Dust protecting filter Mounting bench HAA37-S AMG How to Select (Flow Capacity l/min (ANR)) Operation Principle AFF Model HAA7 HAA15 HAA22 HAA37 AMl 50C 70C 100C 1000 1500 700 2200 4000 1500 3300 6000 2200 5700 13000
(Example) SS3YJA7-41-03-01. 1 set SYJA714 . 2 sets SYJ700-10-2A . 1 set (Example) SS3YJA5-40-03-01. 1 set SYJA514 . 2 sets SYJ500-10-3A . 1 set The asterisk denotes the symbol for assembly.
For Water 30 20 VX2 60-02 10 VX234.5 VX2 46 VX2 6010 VX2 50 8 3 2 04 03 3 2 3 2 VX223 10 3 2 VX2112 5 4 3 Flow rate Q l/min 2 1 0.001 (0.0018) (0.0054) 0.01 (0.017) 0.05 (0.07) 0.1 Pressure differential P = (P1 P2) MPa How to read the graph When a water flow of 2 l/min is generated, lP 0.017 MPa for a valve with 3 orifice (VX212, 222, 232).