Do not use a load that generates surge voltage.
Caution Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Warning Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Danger Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. Warning 1.
Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or Caution moderate injury. Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death Warning or serious injury. Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or Danger serious injury. Warning 1.
PB B A B A B A N.C. N.O. Double acting Double acting With flow rate adjustment PA PA N.C. B A PB B A Double acting N.C. Double acting With by-pass PA PA N.C. PB B A B A Double acting N.C. Double acting With flow rate adjustment & by-pass PA PA N.C. PB B A B A Double acting N.C.
Switch Proper Mounting Position (Detection at Stroke End) and Its Mounting Height Auto Switch Proper Mounting Position (mm) D-A3 D-A44 D-G39 D-K39 D-G5NBL D-H7 D-H7C D-H7W D-H7NF D-H7BAL Auto Switch model D-C7 D-C80 D-C73C D-C80C D-M9 D-M9W D-B5 D-B64 D-B59W D-A9 D-G5NTL Bore size (mm) A B A B A B A B A B A B A B A B 20 55.5 30.5 59.5 34 56 31 50 25 53 28 49.5 24.5 55 30 51.5 26.5 25 55.5
Switch Proper Mounting Position (Detection at Stroke End) and Its Mounting Height Auto Switch Proper Mounting Position (mm) D-A3 D-A44 D-G39 D-K39 D-G5NBL D-H7 D-H7C D-H7W D-H7NF D-H7BAL Auto Switch model D-C7 D-C80 D-C73C D-C80C D-M9 D-M9W D-B5 D-B64 D-B59W D-A9 D-G5NTL Bore size (mm) A B A B A B A B A B A B A B A B 20 55.5 30.5 59.5 34 56 31 50 25 53 28 49.5 24.5 55 30 51.5 26.5 25 55.5
2 OUT A IN OUT t BLEED A-A w y Note Component Parts Material No.
CEP1 CE1 A magnetic field of 14.5 mT is equivalent to a position that has about 18 cm radius from a welded part using about 15,000 amperes of welding amperage. When using it in a stronger magnetic field, cover the sensor with magnetic and shield it.
Devise a safe system so that if a person engages the emergency stop or if a safety device is tripped during a system malfunction,such as a power outage, the operation of the magnet gripper will not cause a hazard to humans or damage the equipment. 7. Consider the action when operation is restarted after an emergency or abnormal stop.
Set of long clamping screws ZH2-TB203-A 3 M4 x 70 2 pcs. ZH13DA ZH15DA ZH2-TB204-A 4 M4 x 90 2 pcs. ZH2-TB206-A 6 M4 x 130 2 pcs. Hexagon nut (M4) 2 pcs. ZH2-TB208-A 8 M4 x 170 2 pcs. (ZH2-TB201-A)3 1 M4 x 30 2 pcs. Flat washer (for M4) 2 pcs. ZH2-TB302-A 2 M4 x 55 2 pcs. ZH2-TB303-A 3 M4 x 80 2 pcs. ZH18DA ZH20DA ZH2-TB304-A 4 M4 x 100 2 pcs. ZH2-TB306-A 6 M4 x 145 2 pcs.
2 OUT A IN OUT t BLEED A-A w y Note Component Parts Material No.
Therefore, make sure to use a pressure regulator to convert line pressure into supply pressure for the actuating valve and the brake valve. In order to actuate multiple cylinders at once, use a pressure regulator that can handle a large air flow volume and also consider installing a surge tank.
Use 0.3 to 0.7 times the thrust (differs depending on the operating speed) as a guide for actual use. g: Gravitational acceleration Dynamic moment Mounting orientation Dynamic load FE Horizontal Ceiling Wall Vertical Z M 1.4 100 x a x mn x g 1 3 a a ME x FE x Z Dynamic moment ME Dynamic moment ME does not occur. 1 3 mn x g ME M3 ME x FE x Y mn x g ME FE FE Note) Regardless of the mounting
(Example) CUJ-M3 x 27l A A C B B D Axial mounting style Lateral mounting style Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Without Auto Switch For Axial Mounting For Lateral Mounting B 21 23 25 27 22 24 26 28 33 22 24 26 28 33 38 22 24 26 28 33 38 Model Mounting
Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Caution: Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Warning: Danger : Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury.
Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Caution: Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Warning: Danger : Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury.
Using a regulator on the secondary side When mounting a regulator on the secondary side (A port side), use a residual pressure relief regulator (AR2550 to 4050) or a check type regulator (AR2560 to 6060). With a standard regulator (AR1000 to 6000), the secondary side pressure may not be released when this valve is exhausted. 5.
size Model Grommet: G Conduit: C Conduit terminal: T M L K H F E D C B N A U S R Q R Q R Q M4 12.8 14 28 12.5 6.5 31 64 28 4.5 13.5 83 66 50 99 50 44 59 22 1/8 VCB21 M4 12.8 18 28 12.5 8.5 31 67.5 36 6 18 86 66 53 99 53 44 62 22 1/4 M5 19 20 32 15 11 36.5 81.5 40 8 22 99 68 66.5 101 66.5 46 76 24 1/4, 3/8 VCB31 M5 23 25 32 15 13.5 36.5 86 50 8 30 104 68 71 101 71 46 80 24 1/2 M5 23 22.5
As a guide, tighten it by hand, then turn it two or three turns with a wrench. Check the dimensions of each product for the hexagon width across flats.
Direction Note) Values for 5 stations manifold with a 2 position single type valve.