mountable number 3 port valve mountable number 00 02 04 00 02 04 No 2 port valves used 2 pcs.
Conditions: Supply pressure 0.7MPa Set pressure 0.2MPa Flow rate 0 l/min (ANR) Conditions: Back pressure 0.5MPa Conditions: Supply pressure 0.5MPa IR2000-02 IR2000-02 IR2000-02 0.204 0.5 0.2 Set pressure MPa Set pressure MPa Set pressure P2 MPa 0.4 0.202 Setting point 0.15 0.3 0.200 0.1 0.2 0.198 0.05 0.1 0.196 0 0.2 0.1 0.4 0.3 0.6 0.5 0.8 0.7 0.9 1.0 0 100 200 300 400 0 100 200 300 400
Manifold can be mounted to VEX1B33, VEX1230 3. 14-6-2 3 Precision Regulator Series VEX130 3 Specifications VEX1B33M5 01 VEX113 01 02 0 3 VEX123 01 02 0 3 VEX133 02 03 04 0 3 VEX153 04 06 10 0 3 VEX173 10 12 0 3 VEX193 14 20 0 3 VEX1A33M5 01 Model Operation Manual (Push locking slotted type) Manual handle (Push locking slotted type) and Air operated type Internal pilot External pilot can be
Box 3385 Al-Amir Majed Street, Jeddah-21471, Saudi Arabia TEL: 02-6761574 FAX: 02-6708173 15-18-21
Operation of the cylinder with its body fixed will damage the wear ring, resulting in increase of particle generation or malfunction. 12-REA40 10-AS2001F-06-X214 10-AS2301F-02-06-X214 10-AS2201F-02-06-X214 12-REA50 10-AS3001F-08-X214 10-AS3301F-02-08-X214 10-AS3201F-02-08-X214 12-REA63 10-AS3001F-08-X214 10-AS3301F-02-08-X214 10-AS3201F-02-08-X214 Although speed adjustment is possible with
connector (20 pins) PH: Flat cable connector (10 pins) Connector entry direction Note Symbol 02 Note Symbol 02 Stations Stations 1: Perpendicular connector 2: Lateral connector 2 stations 2 stations Double wiring specification ... ... ... ... ... ...
-963-7099 Fax: 02-501-2937 Chile Phone: 02-270-8600 Fax: 02-270-8601 United Kingdom Phone: 01908 563888 Fax: 01908 561185 Italy Phone/Fax: 02-9271365 Rochester Phone: (716) 321-1300 Fax: (716) 321-1865 Dallas Phone: (972) 446-9554 Fax: (972) 446-5931 Oceania Australia Phone: 02-9354-8222 Fax: 02-9894-5719 Netherlands Phone: 020-5318 Fax: 020-5318880 Mexico Phone: 47-22-55-00 Fax: 47-22-59
m AFJ20-02-40-S/AFJ30-03-40-S/AFJ40-04-40-S AFJ20-02-40-T/AFJ30-03-40-T/AFJ40-04-40-T 12 12 AFJ20-02-40-T AFJ30-03-40-T AFJ20-02-40-S AFJ30-03-40-S AFJ40-04-40-S 10 10 Pressure drop [kPa] Pressure drop [kPa] 8 8 AFJ40-04-40-T 6 6 4 4 2 2 Water drop removal type Nominal filtration rating: 40 m Large flow type Nominal filtration rating: 40 m 0 0 0 100 200 300 400 500 600 800 700 900 Flow rate
mountable number 3 port valve mountable number 00 02 04 00 02 04 No 2 port valves used 2 pcs.
1 e VV5QC 4 1 16 SDQ 02 S Kit VQC4000 series y i o !
For G thread, be sure to use this adapter. 3.3 Installation HRS Series 3-28 DOC1001322 Chapter 3 Transport and Setting Up How to connect piping Hold the each piping port with a wrench and tighten the piping. Connection port Sealant Note: When using the Y strainer of the accessory, fasten it on the return port.
(B contact). (1) (2) (3) Setting of contact output signal 1 to 3 Table 5.4-28 Setting of contact output signal 1 to 3 No.
Silencer Compact resin type Metal body type High noise reduction type Part Part number number AN20-02 AN30-03 AN40-04 AN500-06 AN600-10 AN202-02 AN302-03 AN402-04 ANA1-06 ANA1-10 Piping size 1/4 3/8 1/2 3/4 1 1/4 3/8 1/2 3/4 1 AMA20#-##C-#-#L# NC AMA20#-##D-#-#L# NO AMA30#-##C-#-#L# NC AMA30#-##D-#-#L# NO AMA40#-##C-#-#L# NC AMA40#-##D-#-#L# NO AMA60#-##C-#-#L# NC AMA60#-##D-#-#L# NO -147No.PF-OMA1007
New New Compact Vacuum Unit Ejector/Vacuum Pump System RoHS Air consumption: 17% reduced 17% 17% 17% 21% 21% 21% Response time of the valve: 21% increased 5 m ms 5 ms Quick response Energysaving Vacuum pressure reached: 25% 28 ms ms Vacuum response time: 28 ms Compared with existing model (Shortened by 25%; Comparison with other SMC products) 0.88 14.5 Air consumption SCFM (L/min (ANR))
Proper tightening torque N m Tightening torque for piping Connection threads 7 to 9 Rc 1/8 12 to 14 Rc 1/4 22 to 24 Rc 3/8 28 to 30 Rc 1/2 28 to 30 Rc 3/4 5. Connection of piping to products When connecting piping to a product, refer to its instruction manual to avoid mistakes regarding the supply port, etc.
L Dimension 21 273 22 285.5 23 298 24 310.5 25 323 26 335.5 27 348 28 360.5 29 373 30 385.5 ZK2 SE2 A 1 No.
Fluid name Applicable element Air (Dry) Lubricating oil (20 mm2/s) Industrial water Fragrances (1 mm2/s) Nominal filtration accuracy (m) Cotton Polypropylene Paper Micromesh Applicable filter model 0.5 Note 1) 10 Note 1) 1 5 10 20 10 5 FGDCA 110 550 11 21 23 26 22 29 03 FGDEA 110 750 12 27 30 36 28 42 04 FGDTA 110 1000 13 32 36 46 32 57 06 FGDFA FGDCB 200 600 17 25 26 28 26 30 03 FGDEB 200
Symbol Pitch ES 17.4 mm Symbol Stations 2 2 3 3 4 4 AC adapter AC cord 96 2144105 1820 L2 L1 Ionizer1 (Order it separately.) 17.4 9.6 28 44 Bracket1 (Order it separately.) Hexagon nut Cleaning kit IZS30-M2 Hexagon socket head cap screw Spacer (5 mm) Part no.
Single numerical data instructions (1 Stations occupied) [Remote IO] PLC memory PLC memory address Signal name address Signal name Rx Ry 00 OUT0 00 IN0 01 OUT1 01 IN1 02 OUT2 02 IN2 03 OUT3 03 IN3 04 OUT4 04 IN4 05 OUT5 05 IN5 06 06 07 07 08 BUSY 08 HOLD 09 SVRE 09 SVON 0A SETON 0A DRIVE 0B INP 0B RESET 0C AREA 0C SETUP 0D WAREA 0D JOG(-) 0E ESTOP 0E JOG(+) 0F ALARM 0F FLGTH 1A to 10
IN OUT How To Order B VHS 30 N 02 Z X513 EXH Residual Pressure Relief 3 Port Valve Dimensions mm With External Epoxy Coating, Stainless Fasteners B C D E F G H I Model A Body Size Symbol 20 30 40 VHS20 VHS30 VHS40 59 78 107 20 29 39 40 53 70 34 46 63 22 45 55 58 33 42 44 28 30 36 45 55 63 Applicable Model AC21 AC31 AC41 Name Plate In Imperial Units (PSI, F) Caution Thread Type N NPT If