Type of Actuation: 2 Position Double, Manifold Type: Body Ported Plug-in Integrated, Pilot: Internal Pilot, Specifications: Standard, Voltage: 12VDC, Electrical Entry: Grommet Lead Wire 0.3m, Lead Wire Length: None, Surge Suppressor: None, Manual Override: Non-locking Push Style, A, B Port Size: Body Ported 1/8, Thread: -, Option: -
Type of Actuation: 3 Position Closed Center, Manifold Type: Body Ported Plug-in Integrated, Pilot: Internal Pilot, Specifications: Standard, Voltage: 12VDC, Electrical Entry: Grommet Lead Wire 0.3m, Lead Wire Length: None, Surge Suppressor: None, Manual Override: Non-locking Push Style, A, B Port Size: Body Ported 1/8, Thread: -, Option: -
Function: 2 Position Single, Piping: Body Ported/Individual Pilot EXH, Voltage: 12VDC, Lead Wire: Grommet Lead Wire 0.3m, Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Thread: -, Option: -
Function: 3 Position Exhaust Center, Piping: Body Ported/Common Pilot EXH, Voltage: 12VDC, Lead Wire: Grommet Lead Wire 0.3m, Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Thread: -, Option: -
Type of Actuation: 2 (2 Position Double), Manifold Type: 20 (Body Ported Plug-in Integrated), Pilot: Internal Pilot, Specifications: Standard, Voltage: 6 (12VDC), Electrical Entry: G (Grommet Lead Wire 0.3m), Lead Wire Length: None, Surge Suppressor: None, Manual Override: Non-locking Push Style, A, B Port Size: 01 (Body Ported 1/8)
Type of Actuation: 1 (2 Position Single), Manifold Type: 20 (Body Ported Plug-in Integrated), Pilot: Internal Pilot, Specifications: Standard, Voltage: 6 (12VDC), Electrical Entry: G (Grommet Lead Wire 0.3m), Lead Wire Length: None, Surge Suppressor: None, Manual Override: Non-locking Push Style, A, B Port Size: 01 (Body Ported 1/8)
:l 3/86 female thread Maintenance l--I space ~ Drain H I I Dimensions with mounting bracket Model Port size A B C D E F G I J 1 K 1 L 1 MI N I 01 P I 01 RI s B AMH850 11 /2 , 2 460.5 42 348 220 57.5 220 10 463.51 180 I 30 I 15 I 24 I 13 1120 1184 1 220 1110 1 18 I 6 6 SeriesAMH Made to Order Specifications ICD With Differential Pressure Gauge (GD40-2-01) I@ With IN-OUT Flange For ease of
Metric size (Release bushing: White color) s3.2, o4, 06, o8, o10, o12 . lnch size (Belease bushing: Orange color) s1 18 . o5n.2', o31 16', s1 14", o51 16', qglS' . 01 2' I Speed may be accurately controlled even at low speeds. I Able to control and set a constant speed easily. I Retainer prevents accidental loss of needle. I Maximum operating pressure 1 MPa max.
Note 1) (1/8), (3/16), 1/4 Lock nut Locks the adjustment knob position.
/t08 c/6 3/8 718-14 7ls t.79 .408 5/8 1t2 718-14 7t8 1.98 .501 Tube To Male Pipe: 90' ELBOW 1i8 1ts 3/16 1t8 3/16 'v4 Consult factory for iniormation 114 1t8 114 114 114 3/8 1t4 1t2 vl6 1/8 112-20 .90 .220 5/16 114 1t2-20 qt .vc .220 5/16 318 1t2-20 .98 1 .01 .219 5/16 'v2 Consult iactory lor iniormation 3i/S 1/8 5/8-18 1.01 .220 3/8 1t4 5/8-18 1.01 1.O5 .283 3/8 3lS y8-18 1.O4 1.07 .28'l
Note) Inch size Metric size KE 23 01 1 8" 3.2 4 6 8 10 12 Control type 5 32" 04 06 08 10 12 03 05 07 09 11 13 3 16" AS-FG Meter-out Meter-in 0 1 1 4" 5 16" AS-FP 3 8" 1 2" With One-touch fitting AS-FM Note) For applicable tubing O.D. selection, refer to the Model on page 630. Use 1/8" tube.
Note 1) 2 1/8, 1/4 3 3/8 4 1/2 Type Metric size Inch size 2 Elbow 3 Universal Tubing O.D. 01 1/8" 03 5/32" 07 1/4" 09 5/16" 11 3/8" 13 1/2" Tubing O.D. 23 3.2 Note 2) 04 4 06 6 08 8 10 10 12 12 16 16 Control type 0 Meter-out 1 Meter-in * Meter-out and meter-in types can be visually identified by color of the knob.
inch (Maintenance space 100mm or more) IDG10, 20 IDG10H, 20H With fittings for purge air discharge (Option: P) (H) Purge air E A Port size L C 41 2.3 Purge air discharge tubing port for dew point indicator Applicable tube O.D.: 8 5/16 inch 14 7 14 16 23 IN OUT Bracket (Accessory: B) (G) B D Purge air discharge tubing port for dehumidification Applicable tube O.D.: J (NPT thread: K inch)
(Refer to page 14-19-16.) Tubing size (O.D. x I.D.) mm: 12 x 9 IDG30 IDG50 0 m 20 1 m 19 3 m 17 5 m 16 Note) In cases other than above model numbers, if the tube length is 5 m or less, an increase of the outlet air at the atmospheric pressure dew point will be 1C or less. Refer to pages 14-19-28 to 29. Construction Refer to pages 14-19-30 to 31.
"-M" ( ) "-M" 13 SI kPaMPa 14 15 () 16 () / ( () ) -29No.PS-OMG0001CN-H OUT1 80mA OUT2 7F.S. 3 ( 4dights ) 1 -30No.PS-OMG0001CN-H PSE3 -100100 kPa 0-101 kPa 0100 kPa 01 MPa 0500 kPa 02 kPa 1 -101101 kPa 10-101 kPa -10100 kPa -0.11 MPa -50500 kPa -0.22 kPa 0.2 kPa 0.1 kPa 0.1 kPa 0.001 MPa 1 kPa 0.01 kPa DC1224 V10P-P10 50 mA() PSE30DC15 V(1 M) PSE31DC420mA100 ) 1 26.4V
cock 10 With auto drain With auto drain 01 11 How to Select Max.
-2No.PS-OML0002CN-G 1 1.5 3) 3) 1 1 () [] -3No.PS-OML0002CN-G () () () () -4No.PS-OML0002CN-G () * UL UL1310 2 UL1585 2 30[Vrms] 42.4[V ]2 UL (100 10 ) JIS B 8392-1 11.1.21.6.2:2003 () -5No.PS-OML0002CN-G * / / ,FG (35N ) () () * () 6 33 () () 10 m DC(-)() () * -6No.PS-OML0002CN-G ( ) () CE 050(5), * ON , 1015 10 /1 2146 LCD * -7No.PS-OML0002CN-G 01 N ISE30A
@numoer ,Inn|i''tral lo'd Double acllng Singte rcd o32 to s4clls lo 1O0 a50 to s1OU10 to 100 Axial piping (c.nri.liEd FiFine) Double acling Single rod o12, o 16/5 to g azo, a25/5 to 50 a32, o4O/5 lo 1N o50 to 01 0C/1 0 to 1 00 Single acting Spdng rctum/er.lend 612lo o4O/5, 10 z5U1O,20 ,.option" 12 to 1m 12 to 10O ,,r,${*i**#{rt$**F_\r;,;tl:r,r. : ..
N 16 16 stations R S Set the maximum number of stations so that there are no more than 16 solenoids for 9 or more stations.
How to Order IZS31 CP X13 L (Tolerance 1%) Cable length 60 L: Cable length Symbol 7 01 02 04 05 06 07 08 09 11 12 13 14 15 16 17 18 19 20 1000 mm 2000 mm 4000 mm 5000 mm 6000 mm 7000 mm 8000 mm 9000 mm 11000 mm 12000 mm 13000 mm 14000 mm 15000 mm 16000 mm 17000 mm 18000 mm 19000 mm 20 mm (Red) 1 12 (6.2) 3 Cable Specifications No. of cable wire 12 0.14 mm2 (AWG26) 0.48 mm Nominal cross section