M H L M E W Y 1/8 LQ1H11-F LQ1H12-F LQ1H21-F LQ1H22-F LQ1H23-F LQ1H24-F LQ1H31-F LQ1H32-F LQ1H33-F LQ1H34-F LQ1H35-F LQ1H36-F LQ1H41-F LQ1H42-F LQ1H43-F LQ1H44-F LQ1H51-F LQ1H52-F LQ1H53-F LQ1H54-F LQ1H61-F LQ1H62-F LQ1H63-F LQ1H64-F 4 3 6 4 6 4 10 8 6 10 8 6 12 10 12 10 19 12 19 12 25 19 25 19 11.5 18.5 10 10 26.5 1/8" Class 1 Rc (NPT) Port size VC 18.5 35 1/8" 16.5 14 15 14 L VDW 21.5
Bore size (mm) 32, 40 50, 63 T2 T1 M F E D B Part No.
5 10 15 20 25 30 kPa Pressure loss [kPa] Pressure loss [kPa] 750 kPa 50 kPa 30 0 kPa 0 kPa 20 30 kPa 50 kPa 70 kPa 750 kPa 350 kPa 10 70 kPa 350 kPa 00 10 20 30 40 50 Flow [L/min] Flow [L/min] PF2M711(-L) 100 L/min PF2M721(-L) 200 L/min 40 90 80 70 60 50 40 30 20 10 00 50 100 150 200 Pressure loss [kPa] Pressure loss [kPa] 750 kPa 30 30 kPa 0 kPa 0 kPa 20 750 kPa 30 kPa 50 kPa 50 kPa 350
-01-06 AS2200-01 AS2201F -01-08 AS2200-01 70% 100 SYJ 200 50 SX 100 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 10% 30% 50% 70% 50% 30% 10% 0 0 200 CM2 25 400 MB 40 150 300 Stroke (mm) Stroke (mm) AS2201F -01-06 AS2200-01 AS2201F -02-08 AS2200-02 100 200 50 100
With light/surge voltage suppressor (Non-polar type) : SY100-30-A U Without lead wire (with connector and 2 of sockets only) Lead wire length Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm Rated voltage 5 6 V S R 1 2 Electrical entry 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] G H L LN LO M MN
(Not including sensor accuracy), Response speed: 150 ms or less Resistance Weight Analog output 0.6% F .S. or less 1.0% F .S. or less 1.5% F .S. or less Accuracy (To display value) (25C) IS Output current: 4 to 20 mA (Within rated pressure range) Current output Note 2) Maximum load impedance: 300 (at 12 VDC), 600 (at 24 VDC), Minimum load impedance: 50 ZSM Linearity: 0.2% F .S.
ZL Operation Solenoid valve (Double, Single)/Air operated valve Power supply voltage 3, 5, 6, 12, 24 VDC, 100, 110 VAC (50/60Hz) ZY Vacuum pressure switch ZQ 0 to 101 kPa Set pressure range ZSE2-0R-15 ZSE4-00---X105 3% or less Hysteresis ZF 12 to 24 VDC (Ripple 10% or less ) Operating voltage ZP Suction filter unit ZR1-F Vacuum to 100 kPa Operating pressure range ZCU 30 m Filtration degree
Nil E Yes Without light, with surge voltage suppressor Seal Metal seal Rubber seal 0 1 Coil voltage Function 1 2 3 Stations 1 2 3 4 5 6 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC D side U side Standard type (1 W) Low wattage type (0.5 W) External pilot Nil Y R (1) (2) Applicable to DC sepecifications.
(Value in the initial state) VA VM VR With Bracket Pilot Pressure Range (Single pilot) Body ported VH Air operated valve type 0.6 SYJA5120-M5-F VHS 0.5 Pilot pressure MPa The mounting bracket is supplied unattached.
0.01 psi 0.02 0.01 0.1 InHg 0.1 0.1 mmHg 1 1 -28No.PS-OMS0006CN-G [F 1] OUT1 OUT1 ONON ONOFF 31 <> [F 1] OFF [OFF]OFF 22 [Err] [P_1] [P1L][P1H] [P_1][n_1] Pn (50 ) -29No.PS-OMS0006CN-G 22 [H_1] [WH1] (50 ) 24 ON ON OFF OFF [F 1] OUT1 1 2 2 -30No.PS-OMS0006CN-G H_1 WH1 WH1 H_1 WH1 WH1 OFF OFF 1Er689 -31No.PS-OMS0006CN-G [F 3] <> [F 3] [F 3] 190% 2(2430) -32No.PS-OMS0006CN-G
ms 50 ms 50 ms 50 ms 7 3-Color Display Digital Flow Switch Series PFMC Construction/Fluid Contact Parts i o !
50 100 100 Load weight (kg) Load weight (kg) B 80 80 A A 63 63 10 10 50 50 B W 5 5 40 40 32 32 B: Retraction locking F: Extension locking 25 25 1 0.5 MPa 0.4 MPa 0.5 MPa 0.4 MPa 20 1 20 0.5 0.5 100 500 Maximum speed (mm/s) 100 500 Maximum speed (mm/s) 9-10-4 4 Series CLQ Specific Product Precautions 2 Be sure to read before handling.
Bore size (mm) T1 M F E D B T2 Part no. 42 50 62 76 6 8 10 12 16 20 25 30 6.8 9 11 14 18 20 26 31 6.5 6.5 8.5 10.5 10 12 16 18 YA-03 YA-05 YA-08 YA-10 32, 40 50, 63 80 100 YA 03 Applicable cylinder bore size 32, 40 50, 63 80 100 03 05 08 10 Mounting bracket Bore size (mm) W V U Weight (g) Part no.
Allowable voltage range 10% Electric system Circuit protector17 A 10 (For option -T-MT : 15 Applicable earth leakage breaker capacity9 A 10 (For option -T-MT : 15 (50/60Hz) A 5.2/6.0 Rated operating current4 For option -T-MT : 6.2/7.6 consumption4 (50/60Hz) kVA 1.0/1.2 Rated power For option -T-MT : 1.2/1.5 Noise level10 (50/60Hz) dB 62/65 Dimensions11 mm W377xD500xH660 (W14.8XD19.7xH26.0
ON/OFF / / 2 2 3 3 1 2 / 11 - 5.3 [] (LEC ) (LEC ) / P.42 7.3 <> (NPNPNP) LEHZ10K2-4 NPN <> INP(IN ) INP ON ON INP ON OFF ) P.50,P.52 8.3 12 - <> No.0 a b c d e f g h i j k a ABSINC ABS() / / INC()// b c ) / P.50 8.3 d e f 0(0 ) g h i )150%/ P.52 8.3 j 12 AREA ON 121 INC ABS() )No.0 120 222 AREA 13 - k INP(IN )ON INP INP ON )0.50 )No.0 22 10 12 INP 14 -
C 5 to 45 Circulating fluid2 Tap water, 15% ethylene glycol aqueous solution, Deionized water Set temperature range1 C 5 to 35 Cooling capacity 50/60 Hz3 kW 8.0/9.0 Heating capacity 50/60 Hz4 kW 1.7/2.2 Temperature stability5 C 0.5 Circulating fluid system Rated flow 50/60 Hz (Outlet)6 L/min 29/45 Maximum flow rate 50/60 Hz L/min 55/68 Maximum pump head m 50 Minimum operating flow rate 50
A C B Applicable model Dimensions [mm] A B C HECR002-A5-E 14 230 35 HECR004-A5-E 45 HECR006-A5-E HECR008-A5-E 44 HECR010-A2-E HECR008-W5-E 46 HECR012-W2-E 310 13 400 15 Option symbol F With Flow Switch F HECR Applicable model HECR002-A5-F HECR004-A5-F HECR006-A5-F HECR008-A5-F HECR010-A2-F HECR008-W5-F HECR012-W2-F With flow switch This is an ON/OFF switch detecting low levels of the circulating
to 500mm/s Standard Strokes Standard stroke (mm) Bore size (mm) 20, 25 32, 40 50, 63 80, 100 15, 20, 25, 30, 40, 50 20, 25, 30, 40, 50, 75, 100 30, 40, 50, 75, 100 40, 50, 75, 100 Manufacture of Intermediate Strokes Method Ordering Method Special body type Refer to "How to Order" for standard part numbers.