For Air 1.0 Downstream pressure of valve (P2) [MPa] Upstream pressure of valve P1z1.0 MPa 0.8 Subsonic 0.9 0.6 Critical pressure 0.8 0.7 Sonic 0.4 0.6 0.5 0.4 0.2 0.3 0.2 0.1 0 3/64 (1.2) 50 100 150 3/32 (2.4) 100 200 300 400 1/8 (3.2) 300 200 100 400 500 600 700 5/32 (4) 200 1, 000 800 400 600 7/32 (5.6) Series VXN2 250 500 7/32 (5.6) Series VXN3 500 1, 000 1, 500 2, 000 Flow rate Q [L/min

Red (DC) Blue 100 VAC 110 VAC 200 VAC 220 VAC Red Blue 100 VAC 110 VAC Red 200 VAC 220 VAC Push type (Tool required) Push down on the manual override button with a small screwdriver until it stops. Release the screwdriver and the manual override will return.

Vertical Horizontal l: Load eccentricity m Mounting position m L L to 100 to 300 Maximum speed mm/s to 500 to 100 to 300 to 500 Load eccentricity lmm 100 50 200 100 50 200 100 50 200 1 2 3 4 5 6 7 8 9 10 11 12 Selection graph L: Overhang (the distance from the cylinder shaft center to the load center of gravity) The direction of L can also be a diagonal direction .

Q 200 VAC 9 50A N.C. S CAC408 50 50A Flange R 230 VAC G N.O.

Outlet air pressure dew point Model Rated inlet condition Air flow capacity (m3/h [ANR]) Port size IDFA100F-38 IDFA125F-38 IDFA150F-38 IDFA100F-40 IDFA125F-40 IDFA150F-40 960 1210 1500 860 1100 1340 R 2 R 2 1/2 DIN flange 80 R 2 R 2 1/2 DIN flange 80 40C 0.7 MPa 10C 35C 0.7 MPa 3C 89 A INDEX 1.

After securing the cylinder, readjust the stroke with the adjustment bolt. 80 Load [N] 70 60 15 50 40 30 10 20 10 0 0 100 200 300 400 500 600 700 800 900 Distance between supports L [mm] Adjuster holder 6. There are limitations on the load mass and operating pressure in case the product is used in the vertical direction.

Standard Stroke Maximum manufacturable stroke (mm) Bore size (mm) Standard stroke (mm) 10 50, 100, 150, 200, 250, 300 500 15 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 750 25 100, 150, 200, 250, 300, 350, 400, 450, 500, 550, 600 1200 The stroke is available in 1 mm increments with the maximum stroke as the upper limit.

After securing the cylinder, readjust the stroke with the adjustment bolt. 80 Load [N] 70 60 15 50 40 30 10 20 10 0 0 100 200 300 400 500 600 700 800 900 Distance between supports L [mm] Adjuster holder 6. There are limitations on the load mass and operating pressure in case the product is used in the vertical direction.

62 15 9 M8 37 29 160 176 125 165 160 Rc(PT) 86.5 104 110 75, 100, 125, 150, 200, 250, 300 88 4 16 9 62 15 9 M8 37 30 160 176 125 165 160 Rc(PT) 86.5 104 110 96 4 19 12 67 18 190 210 135 11 200 42 194 Rc(PT) 35 142 115 M10 95 J I GR GQ GL P Q U O T N S W K L M R V Bore size (mm) 20 25 32 40 60 35 4 4 5.5 M5 X 0.8 93 M6 X 1 16 25 26 50 80 50 12 53 105 112 70 40 7 7 9 M5 X 0.8 M8 X 1.25 20

(Adjustable) Hysteresis Data ON: when output is ON (Red) ON: when output is ON (Red) ON: when output is ON (OUT1: Red, OUT2: Green) Indicator light Trimmer adjustment 3 turns 200 degrees 3 turns 200 degrees 3 turns 200 degrees None 1 to 5 V 5% F .S.

Suitable 20 for m and 0.7 for . 1000 ML2B 6 10 15 20 25 30 40 50 63 80 100 125 140 160 180 200 250 300 0.057 0.099 0.113 0.120 0.184 200 300 400 500 E1 4.9 J In the case of cylinder stroke at load and free horizontal impact, 0.157 0.274 0.314 0.334 0.511 C J G5-S E1 or E substitute respective figures for Data A in order to calculate E1. 100 Impact object weight m or corresponding weight

. -16No.PF-OMP0001CN-F FG 1 DC(+) 2 OUT2// 3 OUT1 4 DC(-) -17No.PF-OMP0001CN-F NPN(2 ) PFMB7--ADC(+) OUT1 OUT2 DC(-) 28 V 80 mA 1 V NPN(1 )(15 V) PFMB7--CNPN(1 )(420 mA) PFMB7--DDC(+) OUT1 DC(-) 28 V 80 mA 1 V C15 V 1 k D420 mA 600 NPN(1 ) PFMB7--GDC(+) OUT1 DC(-) 28 V 80 mA 1 V 0.4V ()30 msec. -18No.PF-OMP0001CN-F PNP(2 ) PFMB7--BDC(+) OUT1 OUT2 DC(-) 80 mA 1.5 V PNP(1 )(15 V)

5 to 75 0.15 to 1.0 2 to 40 (Relative humidity of 85% or less) Single phase, 100/100 to 110VAC (50/60Hz) Single phase, 200/200 to 220VAC (50/60Hz) Single phase, 220, 240/200 to 240VAC (50Hz) Power source 225 275 205 240 182 189 250 350 220 280 265 275 305 380 300 350 280 295 340 415 325 375 332 50Hz 60Hz 50Hz 60Hz 50Hz 50Hz 50Hz 100 VAC 200 VAC Power consumption (W) 220 to 240VAC 220VAC

210.5 9 182 194 225 235.5 10 201 213 237.5 248 3 68 80 100 110.5 4 87 99 125 135.5 5 106 118 137.5 148 L1 L2 L3 L4 2.10-16 VQZ100/200/300 Body Ported Manifold Options Blank plate VVQZ100-10A-2 VVQZ200-10A-2 VVQZ300-10A-2 This is used when removing the valve for maintenance, or reserving a valve mounting space on the manifold for future use.

Reference dimensions of 10-32 UNF and NPT threads after installation. 15-9-80 7 Speed Controller Adjustable by Flat Head Screwdriver with One-touch Fittings Series AS1F-D In-line Type Model Applicable tubing O.D.

kPa) 80 kPa 220 kPa () OUT1 (OUT1) 80 mA OFF, OUT2 (OUT2) 80 mA OFF, (14 kPa ) OFF 220 kPa () -20 kPa220 kPa (-20 kPa) -66No.PS-OMT0001CN-E 5 [ON/OFF] [] () [kPa] -67No.PS-OMT0001CN-E Revision history A [2018 3 ] B [2018 6 ] C [2019 9 ] D [2021 10 ] E [2022 6 ] 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +81 3 5298 5362 URL https://www.smcworld.com

200200 300 34 84 122 172 50 4 4.5 3 6 16 22 46 40 M8 x 1.25 92 24 48 124 200 300 36 86 124 174 66 5 6 4 8 20 24 48 50 M10 x 1.5 28 52 128 200 300 38 50 88 124 174 110 80 5 6 4 8 20 24 63 M10 x 1.5 MLGPM (slide bearing)/A, DB, E dimensions MLGPL (ball bushing)/A, DB, E dimensions A E A E Bore size (mm) Bore size (mm) DB

100 100 150 150 200 200 1500 0 150 300 450 600 750 900 1050 1200 1350 1500 0 150 300 450 600 750 900 1050 1200 1350 Distance [mm] Distance [mm] 5) Supply pressure: 0.4 MPa Flow rate consumption: 316 L/min (ANR) 6) Supply pressure: 0.5 MPa Flow rate consumption: 390 L/min (ANR) 200 200 2 s 150 150 1.5 s 100 100 50 50 0.5 s 1 s 1.5 s 0.5 s 1 s 50 50 100 100 150 150 200 200 1500 0 150 300 450

, 250, 300, 350 400, 450, 500 15 1000 Note 2) 20 1500 100, 150, 200, 250, 300, 350, 400, 450 500, 600, 700, 800 25, 32 3000 100, 150, 200, 250, 300, 350, 400, 450 500, 600, 700, 800, 900, 1000 40 3000 Note 1) Contact P/A if the maximum stroke will be exceeded.