O 54 66 66 80 80 88 88 102 136 P 70 84 84 100 100 110 110 130 180 Q 26 28 28 34 34 50 50 60 76 R 4.5 5 5 5 5 9 9 10 12 S 1.6 2 2 2.3 2.3 3.2 3.2 4.5 4.5 T U 37 37 37 37 37 37 37 37 37 AMH150 1 8 1 4 3 8 166 187 187 218 218 241 241 277 334 24 27 27 32 32 37 37 39 55 159 172 178 204 210 225 232 259 311 13 13 16 16 19 19 22 22 32 100 113 119 145 151 166 173 200 253 63 76 76 90 90 106 106 122

The following amount is needed per one 100 stroke cylinder. STROKE or 100mm and more Table 10. Grease apply amount 2 125 140 160 Portion to apply 100st 1517 2022 2426 50st Up 3 3 3 For grease, use lithium soap group grease JIS #2 3. Mounting seal 21 - . Cushion seal/Rod seal Mount in correct direction. .

O 54 66 66 80 80 88 88 102 136 P 70 84 84 100 100 110 110 130 180 Q 26 28 28 34 34 50 50 60 76 R 45 5 5 5 5 9 9 10 12 S 1.6 2.0 2.0 2.3 2.3 3.2 3.2 4.5 4.5 T U 37 37 37 37 37 37 37 37 37 AFF 159 172 178 204 210 225 232 259 311 13 13 16 16 19 19 22 22 32 100 113 119 145 151 166 173 200 253 63 76 76 90 90 106 106 122 160 20 20 20 20 20 20 20 20 20 63 76 76 90 90 106 106 122 160 24 27 27 32

Options J: With drain guide T: With element service indicator Element service indicator Dimensions with mounting bracket Model Port size (Nominal size B) A B C D E F G H 10 10 10 10 10 10 10 10 10 I 56 66 66 80 80 90 90 100 150 J 15 20 17 22 19 25 21 30 40 K 5 8 8 8 8 10 10 10 15 L 9 12 12 14 14 14 14 16 20 M 5.5 6 6 7 7 9 9 9 11 N 35 O 54 66 66 80 80 88 88 102 136 P 70 84 84 100 100 110

200 300 400 500 600 700 800 900 1000 0 0 100 200 300 400 500 600 700 800 900 1000 Flow rate l/min(ANR) Flow rate l/min(ANR) ARX21-01 ARX21-02 0.35 0.35 0.30 0.30 Downstream pressure MPa Downstream pressure MPa 0.25 0.25 0.20 0.20 0.15 0.15 0.10 0.10 0.05 0.05 0 0 50 100 150 200 250 300 350 400 450 500 0 0 50 100 150 200 250 300 350 400 450 500 Flow rate l/min(ANR) Flow rate l/min(ANR) Pressure

Example: Set 20 W (100 W 20%) for the 100-W external Regenerative resistor with natural convection cooling method: Pn600 = 2 (unit: 10 W) Note 1. If Pn600 is not set to the optimum value, alarm A.320 will occur. 2.

Example: Set 20 W (100 W 20%) for the 100-W external Regenerative resistor with natural convection cooling method: Pn600 = 2 (unit: 10 W) Note 1. If Pn600 is not set to the optimum value, alarm A.320 will occur . 2.

(MPa) VEX 0.25 0.25 0.20 0.20 AMR 0.15 0.15 ITV 0.10 0.10 IC 0.05 0.05 0 0 50 100 150 200 250 300 350 400 450 500 0 0 50 100 150 200 250 300 350 400 450 500 VBA Flow rate (/min (ANR)) Flow rate (/min (ANR)) VE VY1 G Pressure Characteristics PPA Inlet pressure: 2.0 MPa Outlet pressure: 0.8 MPa Flow rate: 60 /min (ANR) Inlet pressure: 2.0 MPa Outlet pressure: 0.3 MPa Flow rate: 60 /min (ANR

(Inch) 1/4 Pressure specifications VQZ 100 VQZ100 VQZ200,VQZ300 (2) A, B port Series VQZ 200 Metal seal VQZ 300 0.1 to 0.7MPa External pilot pressure range (1) Note) Millimeter size One-touch fittings (Cl) are also available.

SMC vacuum pad Search http://www.smcworld.com Catalogs ZP2 ES100-76 ZP3 ES100-100 Best Pneumatics Pad diameter Symbol 16 18 20 25 30 32 40 46 50 63 80 100 125 150 250 300 340 U C C C C C C MU EU AU C C C C C C C UM UT C ( ( CT C C B C C C C C Note) Note) J ( ( ( MB ( ZJ ( ( D C C C AN Note) Note) Note) MT ( ( ( W U H C C C C C C ( ( ( HT ( ( HB C C C C ( C C ( 30 x 50 ( HW U ( ( ( (

Multistage Ejector Series ZL112/212 Energy saving, large flow rate, 3 stage diffuser construction Series ZL112/212 Suction flow rate increased 250% and air consumption reduced 20% with 3 stage diffuser construction (Versus 1.3, one stage model) 1 stage performance Maximum suction flow rate l/min (ANR) Air consumption l/min (ANR) Vacuum pressure Q1 Q2 Q3 ZL112 100 200 ZL212 63 126 Q1 Q2 Q3

112.5 125 125 137.5 150 L3 60.5 73 85.5 98 110.5 123 135.5 135.5 148 160.5 7.5 29 18 n L 11 12 13 14 15 16 17 18 19 20 L1 141 152 163 174 185 196 207 218 229 240 L2 162.5 175 187.5 187.5 200 212.5 225 237.5 250 250 L3 173 185.5 198 198 210.5 223 235.5 248 260.5 260.5 How to Order Single unit, double check block 2-position 1(P) 5(R1) 5(R1) VQ1000 FPG C4 M5 F 1(P) 3(R2) 3(R2) OUT

Normally closed (N.C.) (8A) 6 1.05 19 8 1.7 31 1.5 0.4 340 10 1.9 34 4.5 0.61 11 250 1.0 6 1.05 19 3 8 (10A) 8 1.7 31 340 0.4 10 2.4 43 (15A) 10 2.4 43 1 2 420 Note) Refer to p.4.0-14 the glossary for detail of max. operating pressure differential and max. system pressure.

32, 40, 50, 63 124 AS3000-03 3/8 810 12.3 810 12.3 221 AS4000-02 1/4 1,670 25.5 1,670 25.5 40, 50, 63 80, 100 214 AS4000-03 3/8 1,670 25.5 1,670 25.5 205 AS4000-04 1/2 1,670 25.5 1,670 25.5 242 AS5000-02 1/4 2,840 44 2,840 44 40, 50, 63 80, 100 233 AS5000-03 3/8 4,270 66 4,270 66 224 AS5000-04 1/2 4,270 66 4,270 66 AS4000 Note) Flow rate values are measured at 0.5 Mpa and 20C.

Bit: 7 0 Byte 1 Offset Baud rate (Communication speed) (bit/s) 500 k 250 k 125 k 50 k 20 k 10 k 1 M 800 k Bit: 7 0 Byte 2 Offset Max. bus cable length (m) 25 50 100 250 500 1000 2000 5000 Power supply wiring Power supply connector Bit: 7 0 Byte 3 Offset M12 5-pin plug B-code (reverse) Bit No. 0 2 4 6 0 0 4 6 No. Description Function Output No.

A /B 90 0.1mm/ 2-1. 2-2 F.G CE1-R** CE1 CEU5 OUT1OUT5 RS-232C OUT1OUT20(bank ) (31 ) 221 () B L F G D 0.5 L 3 Z 12 12mm 20 20mm 32 32mm 40 40mm 50 50mm 63 63mm 4063 N R H (mm) (mm) (mm) 25 50 75 100 125 150 175 200 250 300 400 500 12 20 32 40 50 63 222 A90 D-A90 M9N D-M9N M9NW D-M9NW A93 D-A93 M9P D-M9P M9PW D-M9PW A96 D-A96 M9B D-M9B M9BW D-M9BW A90V D-A90V M9NV D-M9NV

32, 40, 50, 63 124 AS3000-03 3/8 810 12.3 810 12.3 221 AS4000-02 1/4 1,670 25.5 1,670 25.5 40, 50, 63 80, 100 214 AS4000-03 3/8 1,670 25.5 1,670 25.5 205 AS4000-04 1/2 1,670 25.5 1,670 25.5 242 AS5000-02 1/4 2,840 44 2,840 44 40, 50, 63 80, 100 233 AS5000-03 3/8 4,270 66 4,270 66 224 AS5000-04 1/2 4,270 66 4,270 66 AS4000 Note) Flow rate values are measured at 0.5 Mpa and 20C.

Free flow Controlled flow Applicable cylinder bore size (mm) Effective area (mm2) Effective area (mm2) Flow rate (/min (ANR)) Flow rate (/min (ANR)) Model Port size Weight (g) AS420-02 2,500 1/4 38 3,600 55 0.34 AS420-03 5,000 3/8 77 4,800 74 0.33 63, 80, 100, 125 AS420-04 6,600 1/2 100 6,700 102 0.32 AS500-06 10,100 3/4 154 8,100 123 140, 160, 180, 200 0.36 AS600-10 15,100 1 230 16,900 258

With barb fitting With drain guide Metal bowl Metal bowl with level gauge Model B B 107 160 214 251 255 B B AC10A AC20A AC30A AC40A 208 246 249 234 272 275 209 247 250 AC40A-06 6 F.R.L.

IFW520 125 VAC 10 to 20 25 1.5 or less 5 5 1.5 0.7 4 4 2.5 1.3 IFW550 250 VAC 20 to 50 60 3 or less 5 5 1 0.5 4 4 1.5 0.8 Note) Hysteresis is the flow rate that is necessary for moving the microswitch from the operation position (ON signal) to the return position (OFF signal). 8 VDC 7 5 3 3 5 4 3 3 5 5 3 3 4 4 3 3 14 VDC 30 VDC 5 5 3 3 4 4 3 3 125 VDC 0.4 0.4 0.1 0.1 0.4 0.4 0.1 0.1 250 VDC