Entry Vertical ~ _~ Connection Male thread Female thread Vacuum ~2~8 Ms x O.8,M6 x l M4 X O.7,MS X O.8 entry Thread 11O ~16 MS X O.8,M6 x l M5 X O.8,M6 x l ,Ys dia. 120-~32 M6 X l ,M8 x l MsxO.8,M6x I ,M8 x l .2S,Y, -140'1S0 M6 X l ,M8 x l M6 Xl,M8 x 1.25, Va Mounting Use connection for vacuum entry NBR(Black!
M1 M2 M3 m1 m2 m3 16 25 40 16 25 40 16 25 40 5 4 3.5 18 16 14 MY2H 13 14 10 35 35 30 45 33 28 68 66 57 7 6 7 15 13 13 MY2H 28 26 26 32 30 30 60 50 60 62 62 62 46 55 46 20 18 18 MY2HT 100 120 100 38 35 35 200 220 200 80 80 80 The above values are the maximum allowable values for moment and load.
Solenoid valve ( ): Effective area [mm2] : Metal : Metal seal Speed controller Composed effective area (mm2) E 64.8 to 67 D 36 to 45 VQ4000 (36.0) VQ4000 (39.6) VFR3000 (41.4) VFS3000 (36.0) G 180 to 300 VFR6000 (191) VFS6000 (180) VP70 (300) F 102.6 to 120 2 Standard type 1 With One-touch fittings C 16.2 to 21.6 VQ2000 (16.2) SY7000 (21.6) SX7000 (21.6) Elbow type 1-A Refer to System
145 30 35 40 45 50 55 60 65 70 75 30 35 40 45 50 55 60 65 70 75 110 135 M5 x 35 x 40 x 45 x 50 x 55 x 60 x 65 x 70 x 75 x 80 x 115 x 140 M6 x 45 x 50 x 55 x 60 x 65 x 70 x 75 x 80 x 85 x 120 x 145 M5 x 30 x 35 x 40 x 45 x 50 x 55 x 60 x 65 x 70 x 75 M5 x 30 x 35 x 40 x 45 x 50 x 55 x 60 x 65 x 70 x 75 x 110 x 135 M3 x 25 x 30 x 35 x 40 x 45 x 50 M3 x 25 x 30 x 35 x 40 x 45 x 50 M5 x 25 x
Data View A-A Mounting dimensions Bore size (mm) Stroke range (mm) N M L K J I B AP AO AN AM AL AK AJ AI AH AG AB AA A 20 25 32 40 50 75, 100, 125, 150, 200 25 38 80 60 44 25 106 22 M6 110 55 9 6.6 90 75 120 105 13 11 84 32 46 95 70 52 30 120 27 M8 125 65 9 9 100 84 136 120 13 15 89 75, 100 125, 150 200, 250 300 32 50 105 80 60 35 135 32 M8 140 75 9 9 108 92 150 134 13 15 94 38 60 125 95
YB-03 32, 40 80 9 6.5 10 18 50 d2 d1 YB-05 50, 63 120 11 6.5 12 22 60 L UT C UA (mm) Part No.
24.5 26.5 66 9.5 7 5 33.6 8 9.2 25 47.5 64 64 26.5 12 110 16 8 25 14 11.5 136 15 M10 x 1.5 28.5 30.5 78 10.5 10 5 41.6 8 9.2 30 56 74 76 35 12 130 20 10 PA (NB) (NA) (N) MM ta M tb Q PW PB P Z TT T QW NN W RW Model Shock absorber 45 RB0805 0.5 M5 x 0.8 M8 x 1.0 8 1.0 90 95 70 M5 x 0.8 CY1L15 CY1L20 CY1L25 CY1L32 CY1L40 112 22.5 12.5 30 92 15 17 27 7.5 Rc 1/8 50 RB1006 M6 x 1.0 10 105 120
M1 M2 M3 m1 m2 m3 16 25 40 16 25 40 16 25 40 5 4 3.5 18 16 14 MY2H 13 14 10 35 35 30 45 33 28 68 66 57 7 6 7 15 13 13 MY2H 28 26 26 32 30 30 60 50 60 62 62 62 46 55 46 20 18 18 MY2HT 100 120 100 38 35 35 200 220 200 80 80 80 The above values are the maximum allowable values for moment and load.
D x 120 (= E) B F 10 3H9 (+0.025 0 ) depth 35 n x 4.5 48 5 4 3H9 (+0.025 0 ) depth 35 3H9 (+0.025 0 ) depth 35 8 G H Motor option: With lock (160.5) Cable length 250 65 20 24 Motor cable 15 Lock cable *1 When mounting the actuator using the body mounting reference plane, set the height of the opposite surface or pin to be 3 mm or more.
End Plate Model EX245-EA2-1 EX245-EA2-2 Bracket Yes No Weight 200 g 150 g EX245-EA24 EX245 Series Dimensions SI Unit End Plate EX245-SPN1 EX245-EA2-1 120 6.5 14 22.1 28.6 6.6 5.6 98.8 148.5 133.5 61.5 1.6 6 85 10 EX245-EA2-2 37 18 120 14 61.5 44 50 130 23 35 Digital Input Module Digital Output Module EX245-DY1 EX245-DX1 22 22 27 13.5 61 120 120 81 27 54 54 61 5 Fieldbus System: For Input/
Withstand Pressure and Heat Resistance Performance 4.0 3.5 3.0 Pressure (MPa) 2.5 2.0 1.5 1.0 0.5 0 20 40 60 80 100 120 140 160 180 200 Temperature (C) 1/8", 3/16", 1/4", 4, 6 tubing 3/8", 10 tubing 1/2", 12 tubing 3/4", 19, 1" tubing Piping Caution 1. Connect tubing with special tools 2.
DataA: Inlet Air Temperature F 80 90 100 110 120 130 140 149 C 27 32 37.8 43 49 54 60 65 IDFB60/IDFB70 1.33 1.21 1.00 0.78 0.61 0.48 0.38 0.28 IDFB80/IDFB90 1.38 1.38 1.00 0.83 0.63 0.50 0.45 0.37 DataB: Ambient Temperature F 80 90 100 110 113 C 27 32 37.8 43 45 IDFB60/IDFB70 1.16 1.11 1.00 0.78 0.71 IDFB80/IDFB90 1.40 1.22 1.00 0.88 0.83 DataC: Inlet Air Pressure psi 50 60 70 80 90 100 120
Circulating fluid flow [L/min] Fig. 8-9 Pump capacity(HRL100-A-20 CH1) 8.5.2 HRL200A20 CH1 0.6 60 0.5 50 Circulating fluid outlet Lifting head [m] Pressure [MPa] 0.4 40 0.3 30 Usable flow rate range 0.2 20 Circulating fluid return 0.1 10 0 0 0 10 20 30 40 50 60 70 80 90 100 110 120 130 Circulating fluid flow [L/min] Fig. 8-10 Pump capacity(HRL200-A-20 CH1) HRL Series 8.5 Pump Capacity 8-
water (pure water)9 / CH2 : Clear water,DI water (pure water) Set temperature range C CH1 : 5 to 35 / CH2 : 10 to 40 Cooling capacity2 kW 9 1 8 19 1 8 26 1 8 Heating capacity3 kW 1.5 1 4.5 1 6.5 1 Temperature stability 4 C CH1 0.1 CH2 0.5 Rated flow rate (Outlet) L/min 45 10 45 10 125 10 (0.43MPa) (0.45MPa) (0.45MPa) (0.45MPa) (0.45MPa) (0.45MPa) Pump capacity Maximum flow rate L/min 120
The maximum number of program steps is 120. Though up to 8 programs can be created, the total number of each program steps is up to 120. The set program can be selected using point table no./program no. selection 1 (DI0) to point table no./program no. selection 3 (DI2). (1) Ex.)
Select cable type and len gth surely. e xamp le S2S2Standard c able 2m+ d river LEC SS2 S2 Standard c able2m Nil Witho ut cab le and driver 100 to 120 LECSB1S B1 200 to 230 LECSB2S B2 100 to 120 LECSC1-S C1 *5 Mo tor cable and enc o der cable are included as a ccessories.
CN3 5.3 CN1CONT (LEC-CG-)(LEC) CN1 (120 1/4W) CN4 CN4 CN4 (LEC) (LEC) (LEC) 8.
80 160 200 20 40 60 Gripping point L (mm) 80 0 20 40 60 Gripping point L (mm) 80 100 120 MHW2-25D MHW2-40D 160 50 Pressure 0.7 MPa Pressure 0.7 MPa MHZ 140 0.6 0.6 40 120 Gripping force (N) Gripping force (N) 0.5 0.5 MHF 100 30 0.4 0.4 80 0.3 MHL 0.3 0.2 20 60 0.2 40 MHR 10 20 MHK 0 20 40 60 Gripping point L (mm) 100 80 80 100 120 140 160 0 20 40 60 Gripping point L (mm) MHS Confirmation
80 160 200 20 40 60 Gripping point L (mm) 80 0 20 40 60 Gripping point L (mm) 80 100 120 MHT MHW2-25D MHW2-40D 160 50 MHY Pressure 0.7 MPa Pressure 0.7 MPa 140 0.6 0.6 40 Gripping force (N) Gripping force (N) 120 MHW 0.5 0.5 100 30 0.4 0.4 80 MRHQ 0.3 0.3 20 60 0.2 0.2 Misc. 40 10 20 D0 20 40 60 Gripping point L (mm) 100 80 20 40 60 Gripping point L (mm) 80 100 120 140 160 0 20Confirmation
(114.5 + A) 125.5 (A + 114.5 + B) 120 (114.5 + A) 120 (114.5 + A) Port size w C06 (C04) 02 (C04) C08 (C06) 02 (C06) 02 (C08) Port size w C10 (C08) 02 (C08) C12 (C10) 02 (C10) 02 (C12) Model Port size q C04 (C06) C04 (02) C06 (C08) C06 (02) C08 (02) Model Port size q C08 (C10) C08 (02) C10 (C12) C10 (02) C12 (02) SFD100SFD200326
Related Products