Symbol Note L V V Cannot be selected when e is N L1 None V L2 V None Cannot be selected when e is P or T L3 None None 4 For the connector length other than 300 mm, order the connector assembly on page 32 separately. t Vacuum (V) port y Option5 (For details on the Function/Application, refer to page 42.)
OFF ON 2.00 1 128/128 32 word/32 word 8 times 7 OFF ON ON 2.00 2 384/384 64 word/64 word 8 times 8 ON ON ON 2.00 3 640/640 96 word/96 word 8 times : The default operation mode at the time of shipment is mode 1. : The last register of bit area (16 bits) cannot be used as they are allocated for the system area.
[115 VAC] 220 VAC [230 VAC] Lead wire length 0.6 m Connector type Lead wire length 3 m Connector type Note) The connector box type and serial transmission type are only available with 5 (24 VDC).
(Example) SYJ3120-5M-M3 VJ3000-13-1 DC AC (50/60 Hz) 5 6 V S R 1 2 3 4 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 200 VAC 110 VAC [115 VAC] 220 VAC [230 VAC] For type W, DC voltage is only available.
Nil Z Nil T F N Rc NPTF G NPT Electrical entry (AC/DC) G -Grommet GS-With grommet surge voltage suppressor C -Conduit Rated voltage 6 7 8 J 1 2 3 4 5 12 VDC 240 VAC 50/60 Hz 48 VAC 50/60 Hz 230 VAC 50/60 Hz 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC T -With conduit terminal TS -With conduit terminal and surge voltage suppressor TL -With conduit terminal and
[Example] 10-SYJ3123-5M-M3 VJ3000-13-1 Rated voltage 5 port DC AC (50/60Hz) 5 6 V S R 1 2 3 4 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 200 VAC 110 VAC [115 VAC] 220 VAC [230 VAC] For type "W", DC voltage is only available.
(Example) 10-SYJ3120-5M-M3 VJ3000-13-1 DC AC (50/60 Hz) CE-compliant CE-compliant 5 6 V S R 1 2 3 4 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 200 VAC 110 VAC [115 VAC] 220 VAC [230 VAC] For type W, only DC voltage is available. Note) CE-compliant: For DC only.
(50 Hz), 3-phase 200 to 230 VAC (60 Hz) Allowable voltage range 10% (No continuous voltage uctuation) Earth leakage breaker Rated current [A] 30 40 50 Sensitivity current [mA] 30 Rated operating current4 [A] 17 32 41 Rated power consumption4 [kW(kVA)] 5.4 (5.9) 10.5 (11.0) 13.1 (14.2) Noise level (Front 1 m/Height 1 m)4 [dB(A)] 75 75 71 Accessories Operation Manual (for installation/operation
Grippers Description Series Bore size Parallel style MHZ2 10 to 40 Parallel style MHZL2 10 to 25 Wide type MHL2 10 to 40 Parallel style MHS2 (2 fingers) 32 to 63 Auto switch mounting screw Parallel style MHS3 (3 fingers)/MHS(L)3 32 to 63 Parallel style MHS4 (4 fingers) 32 to 63 Auto switch Angular style MHC2 10 to 25 1.
ASN How to Order AQ ASN2 03 ASV JIS Symbol AK Option Nil S None With seal ASS Port size ASR M5 U10/32 01 02 03 04 M5 x 0.8 10-32 UNF 1/8 1/4 3/8 1/2 ASF Thread type Metric thread (M5) Unified thread (10-32 UNF) R NPT Nil N Needle Valve/Flow Characteristics Inlet pressure: 0.5 MPa Flow rate (l/min (ANR)) Effective area (mm2) Number of needle rotations 15-11-1 Series ASN Construction Component
Refer to pages 11-3-31 to 11-3-32 for details of made-to-order specifications.
(No condensation) Withstand voltage 500 VAC for 1 minute between external terminals and F.E. Insulation resistance 500 VDC, 10 M or more between external terminals and F.E.
One SI unit can be connected with manifold valves with up to 32 output s and the input output I/O units with maximum 10 units. SI unit: Performs Fieldbus communication and solenoid valve manifold ON/OFF output. Digital input unit: For connecting sensors with switch output capability. PNP and NPN types are available.
OUT1: Green, OUT2: Red IP40 5 to 50C 1000 VAC for 1 minute between terminals and housing 50 M or more (500 VDC measured via megohmmeter) between terminals and housing 2% F.S.
Refer to pages 11-3-31 to 11-3-32 for details of made-to-order specifications.
Refer to pages 11-3-31 to 11-3-32 for details of made-to-order specifications.
(No condensation) Withstand voltage 7 1000 VAC, for 1 minute between the terminals and housing Insulation resistance 50 M min.
Description Decimal Common Format "Data-INT" "Data-SINT" Input MIN. 1 word MAX.32 words MIN. 2 byte MAX.64 byte Output MIN. 1 word MAX.32 words MIN. 2 byte MAX.64 byte Configuration 0 word 0 byte : Select the setting depending on the existence of diagnostic data and the unit type connected. (1) (4) (5) (2) (3) -68No.EX-OMS0027 Device Level Ring (DLR) function This SI unit can be used as
(No condensation) Withstand voltage 500 VAC for 1 minute between external terminals and F.E. Insulation resistance 500 VDC, 10 M or more between external terminals and F.E.
Output channel 32 outputs (8/16/24/32 outputs selectable) Valve output Connected load Solenoid valve with lamp and circuit of protection of surge voltage of 24 VDC 1.5 W (SMC) Power supply (output) 24 VDC Class2, 2 A Output for com. error HOLD/CLEAR/Force ON Protective function Short circuit protection Enclosure IP67 (with manifold assembled) 1 Operating temperature range -10 to 50 oC (Max