range 1.0 MPa 0.05 to 0.85 MPa Set pressure + 0.05 MPa (2) (at relief flow rate of 0.1 l/min (ANR)) Relief pressure Ambient and fluid temperature 5 to 60C (With no freezing) 5 m Nominal filtration rating Recommended lubricant Class 1 turbine oil (ISO VG32) Regulator construction Relieving type Bowl material Polycarbonate Bowl guard Standard Optional Sight dome material Polycarbonate Weight (kg

pressure range 1.0MPa 0.05 to 0.7MPa 0.05 to 0.85MPa Set pressure + 0.05MPa Note 2) [at relief flow rate of 0.1L/min (ANR)] Relief pressure Ambient and fluid temperature 5 to 60C (with no freezing) 5m Nominal filtration rating Class 1 turbine oil (ISO VG32) Polycarbonate Recommended lubricant Bowl material Option Bowl guard Filter regulator construction Relieving type 0.75 0.59 Weight (kg

Length of gripping point: 25mm Operating pressure: 0.4MPa Model selection illustration When gripping a work piece as in the figure to the left and with the following definitions, F: Gripping force (N) : Coefficient of friction between attachments and work piece m: Work piece mass (kg) g: Gravitational acceleration (= 9.8m/s2) mg: Work piece weight (N) F F F F the conditions under which the

35.320 L 0.0353 L 0.2642 Weight g 0.0353 kg 2.2046 1.356 N . m 1.356 J 3.6 l\rJ mm3 cm3 (cc) m3 L L rn3 in3 Energy ft3 N. m f t 3 J gar(u.s.)

RSH20, 32 Graphq Graphw 1.0 RSH20 RSH32 0.9 Bore size 50, 63, 80/ = 0 Bore size 50, 63, 80/ = 0.1 Operating pressure P [MPa] 0.8 1300 1300 80 0.7 1200 1200 0.6 1100 1100 0.5 1000 1000 0.4 900 900 0.3 63 80 Load weight m [kg] Load weight m [kg] Load weight m [kg] Load weight m [kg] 0.2 800 800 50 0.1 700 700 600 600 0 500 100 200 300 400 63 Lateral load F [N] 500 500 50 400 400 RS1H50, 63,

Switch spacers Applicable bore size (mm) 32, 40 50, 63 80, 100 Weight table (kg) BMP1-032 Switch spacer Bore size (mm) 32 80 63 50 40 100 Mounting brackets/Part nos.

Light weight & compact Series XMA with KF(NW) flange Model Weight kg A mm B mm Conductance l/s XMA-16 5 0.33 40 103 XMA-25 XMA-40 XMA-50 14 0.61 50 113 B 45 1.40 65 158 80 2.00 70 170 A 160 XMA-63 XMA-80 3.60 196 88 200 6.20 90 235 : Common to all series.

Selection Procedure Remarks Selection Example Operating conditions 0 r = 25, 0.2 kg Load 2 Operating conditions are as follows: Provisionally selected model Operating pressure: MPa Mounting position Load type Static load: Nm Resistance load: Nm Inertial load: Nm Load dimension: m Load mass: kg Rotation time: s Rotation angle: rad See P. 314 for load type. 100 50 0.4 kg The unit

(including M10 bolts 4pcs.)9 Weight(dry condition) kg Approx.130 1 Use 15% ethylene glycol aqueous solution if operating in a place where the circulating fluid temp. or ambient temperature is lower than 10 oC 2 Use fluid in condition below as the circulating fluid.

Pressure gauge connecting direction: 2 directions (Front/Back) Weight: 0.66 kg (Adjustable type), 0.58 kg (Fixed type) How to Order IW 02 2 2 1 Filter regulator Accessories Nil None B With bracket G With pressure gauge Type of setting 1 Adjustable type (Knob) 2 Fixed type (0.14 MPa) Port size Set pressure 02 1/4 2 0.02 to 0.2 MPa 3 0.02 to 0.3 MPa 5 0.02 to 0.5 MPa * Fixed type is IW222

Read off Q0 when P1 is 0.8 and DP is 0.008 in Graph (2), the reading is 20 [kg/h]. Therefore, the flow rate is calculated as the formula: Q = 0.05/1 x 20 = 1 [kg/h]. Specific Product Precautions 58 JSXD Series Flow Rate Characteristics * Use this graph as a guide. In the case of obtaining an accurate flow rate, refer to pages 54 to 58.

Weight of each model with packaging: IDFB60: 126 lbs (57 kg), IDFB70: 172 lbs (78 kg), IDFB80: 234 lbs (106 kg), IDFB90: 269 lbs (122 kg) Compressor Air Delivery Caution Since the auto drain is designed in such a way that the valve remains open unless the air pressure rises to 14.5 psi (0.1 MPa) or higher, air will blow out from the drain outlet at the time of air compressor start up until

CL Ek: Kinetic energy of load (J) m: Load weight (kg) : Piston speed (m/s) (Average speed x 1.2 times) Ek = m2 1 2 CL1 3. The piston speed will exceed the average speed immediately before locking. To determine the piston speed for the purpose of obtaining the kinetic energy of load, use 1.2 times the average speed as a guide. 4.

Size Current model [kg] Reduction rate [%] CRA1 [kg] Angle adjustable type 30 50 63 80 100 0.3 10 0.27 Size: 50, 63, 80, 100 Size: 50, 63, 80, 100 1.5 13 1.3 D50 to 100 50 to 100 Rotating angle 2.5 12 2.2 90, 180, 100, 190 90, 180, 100, 190 4.3 10 3.9 8.5 14 7.3 With solenoid valve Size: 50, 63, 80, 100 Size: 50, 63, 80, 100 Mounting interchangeable with the current model 50 to 100 50 to

Selection Procedure Remarks Selection Example Operating conditions 0 r = 25, 0.2 kg See P. 304 for load type.

Read off Q0 when P1 is 0.8 and P is 0.008 in Graph (2), the reading is 20 kg/h. Therefore, the flow rate is calculated as the formula: Q = 0.05/1 x 20 = 1 [kg/h]. 161 VXD Series Flow Rate Characteristics Note) Use this graph as a guide. In the case of obtaining an accurate flow rate, refer to pages 157 through to 161.

According to Graph (2), if reading Q0 when P1 is 0.8 and $P is 0.008, it is 0.7 [kg/h]. Therefore, the flow rate Q = 0.7 x 1.5 = 1.05 [kg/h]. (4) Test method Attach a test equipment with the test circuit shown in Fig. (3). Next, pour water at 5 to 40oC, then measure the flow rate with a pressure differential of 0.075 MPa.

Temperature distribution of the 120C specification Comparison with a KF25 flange 140 e, r, t 120 eBody 1 Temperature [C] 100 rBody 2 tBody 3 80 q, w 60 40 Heater wBellows 20 qValve 0 0 30 60 90 Time [Minute] Lightweight, Compact Large conductance, small body, excellent resistance against fluorine corrosion (body) XLA series Model A1 [mm] B [mm] Weight [kg] Conductance1 [L/s] XLA-16-2 40 108

FKM (Standard seal material) Principle materials Pilot pressure (MPa)(G) 0.3 to 0.6 0.4 to 0.6 Pilot port size M5 Rc 1/8 XMC 6.30 0.62 1.40 (1.76) 2.10 3.80 (5.16) 0.36 (0.40) Weight (kg) Note 2) XYC 7.80 0.67 1.42 2.50 4.50 Note 1) Conductance is the value for the molecular flow of an elbow having the same dimensions.

Motion on RECL32-300 ML1C REA REC Pressure fluctuation Load fluctuation Speed fluctuation RHC 0.5 0.5 0.3 0.5 Pressure (MPa) Pressure (MPa) Pressure (MPa) Reducing actuation cycle time 10 10 30 10 Load (kg) Load (kg) Load (kg) MTS 100 300 300 Speed (mm/s) Speed (mm/s) Speed (mm/s) 300 CC Max. 500mm/s of high speed transfer is possible.