Inappropriate specifications Leave an interval of a minimum of 15 ms (recommendation is 30 ms) between input signals and maintain the state of the signal for a minimum of 15 ms (recommendation is 30 ms), because PLC processing delays and controller scanning delays can occur. 8.4 Controller input signal response Move occasionally Signal timing Check the timing of the signal from the PLC to
Power consumption: 0.6W (Current: 25mA, 24VDC) A relay output module is available for control of devices up to 110VAC, 3A.
oO OUT 12,17 304 609 913 1217 1522 1765 30 IN 11 .08 277 554 831 1108 1385 1606 Note) Theoretical outpul(lbl) :: Pressure (pSI) X Piston area (IrI(:h2) Bore SlZ9 .
LEY40#EA: 9 kg, LEY40#EB:19 kg, LEY40#EC:38 kg LEYG40#EA:7 kg, LEYG40#EB:17 kg, LEYG40#EC:36 kg 10 mm minimum Door (Lid) 30 mm minimum Controller 60 mm minimum 30 mm minimum (direct mounting) 50mm or more (DIN rail mounting) Controller Caution If the mounting surface for the controller is not flat or is uneven, excessive stress may be applied to the enclosure, which can cause failure.
(deg) 1/4 15 to 30 4 to 5 3/8 15 to 30 8 to 9 1/2 15 to 30 14 to 15 Air Supply 1. Use clean air 2) The gasket can be reused up to 6 to 10 times. It can be replaced easily when it has sustained damage. A broken gasket can be removed by holding it and then turning it in the same direction as loosening the thread. If the gasket is difficult to remove, cut it with nippers, etc.
(Example) SS3YJA7-41-03-01. 1 set SYJA714 . 2 sets SYJ700-10-2A . 1 set (Example) SS3YJA5-40-03-01. 1 set SYJA514 . 2 sets SYJ500-10-3A . 1 set The asterisk denotes the symbol for assembly.
Socket only (3 pcs.) 300A 600A 1000A 2000A 3000A AXT661-13A AXT661-13A-6 AXT661-13A-10 AXT661-13A-20 AXT661-13A-30 AXT661-13AN AXT661-13AN-6 AXT661-13AN-10 AXT661-13AN-20 AXT661-13AN-30 AXT661-14AN AXT661-14AN-6 AXT661-14AN-10 AXT661-14AN-20 AXT661-14AN-30 100/110 VAC for single: AXT661-31A-; for double: AXT661-32A200/220 VAC for single: AXT661-34A-; for double: AXT661-35Aare in accordance
Valve model Port size VCL2 VCW20-12-01 1/8, 1/4 34 40 25 30 12.8 12.8 5 4.5 6 13 VCW30-12-02 1/4, 3/8 42 52 30 40 19 19 6 5.5 7 19 VCL3 VCW30-12-04 1/2 48 56 36 44 23 23 6 5.5 7 23 VCW40-12-02 1/4, 3/8 42 52 30 40 23 23 6 5.5 7 19 VCW30-12-04 VCL4 1/2 48 56 36 44 23 23 6 5.5 7 23 VCW40-12-06 3/4 56 65 44 53 28.2 28.2 6 5.5 7 26 Bracket material: Stainless steel 3 Series VCL Direct Operated
degC Fig. 6-1 Cooling capacity 2) Heating capacity Fluid: water Fluid: water 1000 2000 900 Ambient 35C 1800 Ambient 30C 800 1600 Ambient 25C Heating capacity W Heating capacity W 700 1400 600 Ambient 20C 1200 500 Ambient 15C 1000 400 800 300 Ambient 15C 600 200 400 100 0 200 10 15 20 25 30 35 40 45 50 10 15 20 25 30 35 40 45 50 Circulating fluid temperature degC Fluid temperature degC Fig
Please refer to the manual of the actuator for more details. 30 - 7.2 Basic parameter The Basic parameter is the data to define the operating conditions of the controller, conditions of the actuator, etc.
(P.23) -9- (6) DC24V LED LED PWR ALM LED 7.LED (P.30) (JXC)LEDALM EtherNet/IP SI I/O 15(P.62) * (7) PLC EtherNet/IP LED LED PWR ALM MS NS EtherNet/IP LED 7LED (P.30) (JXC)LEDNSPLC PLC 19(P.78) PLC -10- (8)() ()() () (9) 9(P.32) PLC 13 (P.52) -11- 3 3.1.
Diagnosis 30 5.1. Diagnostics data on I/O mapping 30 5.2. Maintenance alarm for the Fibre-optic cables 34 6. SI Unit 35 6.1. Parts and description 35 6.2. Specifications 37 6.3. Process data for valves 39 6.4. LED indicators 40 6.5. Block diagram 43 7. Digital Input Module EX245-DX1 46 7.1. Parts and description 46 7.2. Specifications 47 7.3. Wiring 48 7.4. Process data 48 7.5.
No.EX-OMW0014CN-A PROFINET SI / / EX245-SPN1A/2A/3A(SI ) EX245-DX1() EX245-DY1() EX245-LA1/LB1(IO-Link ) EX245-EA2-() 1. 11 1.1. 11 1.2. 12 2. 13 3. 14 3.1. 14 3.2. 16 4. 22 4.1. 22 4.2. 26 5. 30 5.1. 30 5.2. 34 6.SI 35 6.1. 35 6.2. 37 6.3. 39 6.4.LED 40 6.5. 43 7.EX245-DX1 46 7.1. 46 7.2. 47 7.3. 48 7.4. 48 7.5 LED 49 7.6. 50 8.EX245-DY1 51 8.1. 51 8.2. 52 8.3. 53 8.4. 53 8.5.LED
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Nil 30 50 0.6 m 3 m 5 m ZL ZY Table (2) How to Order Connector for Supply Valve and Vacuum Release Valve ZQ 1A 36 VJ10 Caution (Applicable to 100 VAC only) ZF When using AC, the DC solenoids are operated via a rectifier.
How To Order Connector Ass y Number vJ1_g-2o--4A-@ ( 1 10VAC: VJ10-36-3A-') ---fvJ10-20-4AL type I a..l wira len.rrh.-i Lead wire length .
How To Order Connector Ass y Number vJ1_g-2o--4A-@ ( 1 10VAC: VJ10-36-3A-') ---fvJ10-20-4AL type I a..l wira len.rrh.-i Lead wire length .
B06 Bottom piping: 3 4 Ordering source area code Code Japan, Asia Australia areas E Europe N North America Dimensions Symbol Model VS7-2A03 A04 VS7-2B03 B04 VS7-2-A06 Port size Piping Side A B C D E F G H J K L M N O P Q R S T U V W X Y 62 4-M6 Depth 10 , 3 8 1 2 75 98 30 50 49 32 23 42 31 36 88 10 16 12 16 10 38 16 23 112 15.5 47.5 Bottom Side 4-M6 Depth 12 72 3 4 86 42 63 62 42 30 55 42
FMW-4200-.5 0.05 0.5 15 0.05 0.15 3A FMW-4200-2-10 0.2 2 30 0.1 0.3 10A FMW-4200-2 0.5 2 30 0.1 0.3 15A FMW-4200-5 0.5 5 30 0.4 0.8 15A FMW-4200-15 0.5 15 45
FMW-4200-.5 0.05 0.5 15 0.05 0.15 3A FMW-4200-2-10 0.2 2 30 0.1 0.3 10A FMW-4200-2 0.5 2 30 0.1 0.3 15A FMW-4200-5 0.5 5 30 0.4 0.8 15A FMW-4200-15 0.5 15 45
FMW-4200-.5 0.05 0.5 15 0.05 0.15 3A FMW-4200-2-10 0.2 2 30 0.1 0.3 10A FMW-4200-2 0.5 2 30 0.1 0.3 15A FMW-4200-5 0.5 5 30 0.4 0.8 15A FMW-4200-15 0.5 15 45