(ZS-50-A) A M4X6L B(ZS-50-B) B M4X6L -14No.PS-OMV0003CN-G -02-N02 8~12 Nm -F02 4~5 Nm 24 () -15No.PS-OMV0003CN-G ()336 336 -16No.PS-OMV0003CN-G FG M12 M12 (Port Class A) 1 DC(+) DC1224 V 2 OUT2 2 3 DC(-) 0 V 4 OUT1 1 IO-Link 1 L+ DC1830 V 2 DO 2 3 L0 V 4 C/Q (IO-Link)/1(SIO) -17No.PS-OMV0003CN-G NPN 2 DC(+) OUT1 OUT2 DC(-) PNP 2 DC(+) OUT1 OUT2 DC(-) IO-Link L+ C/Q IO-Link
3.3 0.40 0.88 3.1 0.51 0.84 VHS3510 1/4 1/4 6.4 0.45 1.7 6.2 0.38 1.7 VHS30 3/8 8.3 0.41 2.3 7.0 0.41 1.9 1/4 7.3 0.49 2.0 8.5 0.35 2.3 VHS40 3/8 10.9 0.45 3.0 11.6 0.40 3.1 3/8 VHS4510 1/2 14.2 0.39 3.8 13.3 0.43 3.6 VHS40-06 VHS4510-06 3/4 1/2 18.3 0.31 5.0 17.7 0.37 4.8 VHS5510 3/4 1/2 23.8 0.41 6.4 21.8 0.41 5.9 VHS50 1 31.9 0.33 8.6 23.5 0.44 6.4 4.
137 92 80 70 M5 x 0.8 x 8 M6 x 1.0 x8 M6 x 1.0 x10 12REA 50/63 0 -0.2 L NA 33 2-Rc, NPT, G 1/4 14 14 E(h8) E(h8) X D I 4-TC 14 14 Effective thread depth R 23 22 K W 23 25 2 4-M8 x 1.25 25 8-Q 14.5 C 0.1 + Effective thread depth 12 Effective thread depth R B S + Stroke 2 ZZ + Stroke Q x R S TC x R Model L 122 110 K 38 32 C 70 60 X ZZ NA E D B 72.2 58.2 I 70 60 W 12-REA63 12-REA50 100 86 66
L1 L2 L3 L4 L5 L6 L7 L8 D Model Bore size ASS AS2000-01 AS2000-02 AS3000-02, 03 1 8 Rc Rc Rc , 40 40 56 30 30 45.5 5 5 5.25 17 23 25 10 11.5 13.2 15.5 17 20.6 54.5 56 68 50 51.5 61 16 20 26 4.5 4.5 5.5 1 4 1 4 ASR Effective thread depth 6 8 3 Dimensions: AS5000 ASF 2-1/4 to 1/2 2-M4 x 0.7 Effective thread depth 7 15-9-31
O.D.: 6 VP4 U D U side D side 2 to 8 2 to 8 9 to 16 D-sub connector cable assembly Symbol VZS B Both sides Passage Porting specifications 4(A), 2(B) Side 5(R1), 3(R2) 1(P) Common Common Stations Symbol VFS 02 2 stations 1 D side VS4 16 stations 16 Max. 16 stations.
Electrical entry SC (T only) Type SU Type SC Type SC Type SU Type SC Type SU AXT622-5A AXT336-4AStations AXT336-5Stations Description AXT336-1A-1 01 02 01 02 01 02 02 03 02 03 02 03 02 03 Manifold block assembly AXT336-1A-2 AXT336-1A-3 AXT336-2A-1AXT336-2A-2AXT336-3A-1AXT336-3A-2q End plate (U side) assembly w End plate (D side) assembly e Terminal assembly Junction cover assembly Tie-rod
How to Order VHS 4 5 1 0 01 Paint color Nil X1 Standard color Handle, body: Red With locking holes Pressure relief 3 port valve Optional specifications Body size Flow direction: Right Left R 4 5 1/2 1 JIS Symbol (A) 2 Port size Double action 02 03 04 06 10 1/4 3/8 1/2 3/4 1 Thread type 3 (R) 1 (P) Nil F N Rc G NPT OSHA standard (Occupational Safety and Health Administration Department of
Dimensions 4-3.2 circuit board mounting hole Circuit board type DC24V MADE IN JAPAN + PCW-EC16Z00 4 4 YMX-F4 42 0 1 2 3 4 5 6 7 8 9 A B C D E F 1 + *S2 S1 2 3 4 4 4 (28.5) 3 130 With cover (DIN rail mount compatible) With cover (DIN rail mount compatible) 16.7 DC24V MADE IN JAPAN + PCW-EC16Z01 28.3 YMX-F4 45 0 1 2 3 4 5 6 7 8 9 A B C D E F 1 + *S2 S1 4.1 2 3 4 (48.5) 5.1 (50) 133 10.5 10.5
Model Pressure range *1 Indication unit Connection thread Note MPa Port size 01 Rc1/8 02 Rc1/4 R1/8 R1/4 G46-7-02-SRB 0 to 0.7 R1/4 G46-10-02-SRB 0 to 1.0 G46-4-01 to 02-SRB 0 to 0.4 MPa Set pressure range: 0.05 to 0.69 MPa 02 WR110 X215 *1: Do not apply more pressure than the max. pressure displayed. It may cause a malfunction.
0.35 (With light: 0.4 (DIN terminal with light: 0.45)) 1 (P) 3 (R) 1 (P) 3 (R) Power consumption (W) DC 0.1 (With light only) External pilot 1.4 (With light: 1.5) 100 V 110 V [115 V] 200 V SYJ51 R 2 4 SYJ52 R 2 4 1.6 (With light: 1.7) [1.7 (With light: 1.8)] (A) 2 (A) 2 Apparent power (VA) AC X X 2.3 (With light: 2.4) 2.5 (With light: 2.6) [2.7 (With light: 2.8)] 220 V [230 V] 1 (P) 3 (R
side) OFF: B-PHASE (Extended side) Output ON command input Red 2 ON Adjusted thrust command input Yellow SET 3 Traveling direction command input A-PHASE 4 Orange Cable for motor output terminal LC3F2 1 C3 02 1 CN3 Motor Output Terminal Table 2 1 Terminal Function Pin number Optional cable color Cable type Cable length 02 05 2 m 5 m Cable for CN3 motor output terminal C3 1 Blue OUTA Motor
VR 2-M5 x 0.8 depth 7 (Mounting screw) VH VHS Dimensions/Manifold VVTA300-1 VVTA300-3 (Pitch) Max. 2 Max. 2 Pilot port Pilot port 4-M4 (Mounting hole) (Mounting hole) 4-M4 (P port) (Pitch) (P , R port) (R port) (A port) (A port) Individual Exhaust Common Exhaust n n: Station n n: Station 2 76 64 3 102 90 4 128 116 5 154 142 6 180 168 7 206 194 8 232 220 9 258 246 10 284 272 2 88 62 3 114
1 3 Port Air Operated Valve Series VZA200/400 Specifications SA Fluid Air 1 2 1 2 VZA4 2, 4 4 1 2 1 2 VZA2 2, 2 4 1 2 1 2 VZA4 2, 4 4 1 2 1 2 VA Operating pressure range (MPa) 0.1 to 1.0 0.15 to 1.0 VZA2 2, 2 4 0.1 to 1.0 0.15 to 1.0 SA Pilot pressure range (MPa) Impact/Vibration resistance (m/s2) Note) 150/50 VA Operating pressure Pilot pressure Note) Impact resistance: No malfunction from
Recommended flow rate Note) (l/min (ANR)) Internal capacity (cm3) 1.7 Mass (g) ZA Model IN side, OUT side 2 3.2 4 4 6 6 8 1/8" 5/32" 5/32" 1/4" 1/4" 5/16" ZFC050-02 ZFC050-23 ZFC050-04 ZFC100-04 ZFC100-06 ZFC200-06 ZFC200-08 ZFC051-01 ZFC051-03 ZFC101-03 ZFC101-07 ZFC201-07 ZFC201-09 2 7 10 10 20 30 50 7 10 10 20 30 50 4.9 ZX IN/OUT straight piping 1.7 4.3 ZR Metric size Easy installation
Metric size Inch size Body size Port size 3 1/8 standard 06 6 07 1/4 Symbol Cylinder side 4 1/4 standard 08 8 09 5/16 01 R1/8 5 3/8 standard 10 10 11 3/8 02 R1/4 6 1/2 standard 12 12 13 1/2 03 R3/8 04 R1/2 N01 NPT1/8 N02 NPT1/4 N03 NPT3/8 N04 NPT1/2 XTO Series Applicable tubing O.D.
3 Port Air Operated Valve Series VZA200/400 Fluid Air 1 2 1 2 VZA4 2, 4 4 1 2 1 2 VZA2 2, 2 4 1 2 1 2 VZA4 2, 4 4 1 2 1 2 Operating pressure range (MPa) 0.1 to 1.0 0.15 to 1.0 VZA2 2, 2 4 0.1 to 1.0 0.15 to 1.0 Pilot pressure range (MPa) Impact/Vibration resistance (m/s2) Note) 150/50 Operating pressure Pilot pressure Note) Impact resistance: No malfunction from test using drop impact tester
SMC Corporation R&D Center Product Development Division-6 Address: 4-2-2, KINUNODAI,TSUKUBAMIRAI-CITY , IBARAKI-KEN 300-2493, JAPAN Phone:+81-297-52-6 Fax:+81-297-20-5007 E-mail:kaihatsu_6_g3@smcjpn.co.jp Notice: The content of this manual can be revised without a previous notice. ii HEF002-A6 Contents Contents 1 PREPARATION FOR COMMUNICATION -1-1 2 OPTIONS OF COMMUNICATION METHOD -2-1 2.1
Fig.3-4 [Ex.-4] In wrong example shown of Fig. 3-2 [Ex.-2] (with external slider mounted directly on load base), the misalignment between guide (orbit) and cylinder is not compensated and may induce operating failure. To eliminate the misalignment and deflection of cylinder by self-weight, clearance is provided between mounting bracket and cylinder as shown on correct example.
Panel Mount Nut Applicable Body Size All All 30, 40 30, 40 All Symbol 02 03 04 Port Size 1/4 3/8 1/2 *Note: Bracket and/or panel mount nut are not assembled and are supplied loose at time of shipment.
Panel Mount Nut Applicable Body Size All All 30, 40 30, 40 All Symbol 02 03 04 Port Size 1/4 3/8 1/2 *Note: Bracket and/or panel mount nut are not assembled and are supplied loose at time of shipment.