Material: Body: Stainless Steel 304; Gasket/O-ring: FKM, Element Length: ℓ250, Port Size R: 2, Element Type: Sintered Metal, Stainless Steel Material, Nominal Filtration Accuracy: 1 μm, Element Seal Material: FKM, Pressure Gauge: -
Material: Body: Stainless Steel 304; Gasket/O-ring: FKM, Element Length: B [ℓ500 (ℓ250 x 2)], Port Size R: 2, Element Type: Sintered Metal, Stainless Steel Material, Nominal Filtration Accuracy: 1 μm, Element Seal Material: FKM, Pressure Gauge: -
Material: Body: Stainless Steel 304; Gasket/O-ring: FKM, Element Length: C [ℓ750 (ℓ250 x 3)], Port Size R: 2, Element Type: Sintered Metal, Stainless Steel Material, Nominal Filtration Accuracy: 1 μm, Element Seal Material: FKM, Pressure Gauge: -
Material: Body: Stainless Steel 304; Gasket/O-ring: NBR, Element Length: ℓ250, Port Size R: 2, Element Type: Micromesh, Stainless Steel 304/Epoxy Material, Nominal Filtration Accuracy: 74 μm, Element Seal Material: NBR, Pressure Gauge: -
Size: 3 [0.37m³/min (ANR), 13.07scfm], Voltage: 20 [200VAC (50Hz), 200/220VAC (60Hz), Single Phase], Option 1: Cool Compressed Air Output, Option 2: -
Size: 11 [1.82m³/min (ANR), 64.27scfm], Voltage: 20 [200VAC (50Hz), 200/220VAC (60Hz), Single Phase], Option 1: Cool Compressed Air Output, Option 2: -
Size: 4 [0.57m³/min (ANR), 20.13scfm], Voltage: 20 [200VAC (50Hz), 200/220VAC (60Hz), Single Phase], Option 1: A+C+L, Option 2: R+T
Size: 4 [0.57m³/min (ANR), 20.13scfm], Voltage: 20 [200VAC (50Hz), 200/220VAC (60Hz), Single Phase], Option 1: A+C, Option 2: Circuit Breaker
Size: 6 [0.82m³/min (ANR), 28.96scfm], Voltage: 20 [200VAC (50Hz), 200/220VAC (60Hz), Single Phase], Option 1: A+K, Option 2: R+T
Size: 11 [1.82m³/min (ANR), 64.27scfm], Voltage: 20 [200VAC (50Hz), 200/220VAC (60Hz), Single Phase], Option 1: Metal Auto Drain Bowl w/Level Gauge; Medium Air Pressure, Option 2: -
Size: 11 [1.82m³/min (ANR), 64.27scfm], Voltage: 20 [200VAC (50Hz), 200/220VAC (60Hz), Single Phase], Option 1: Heavy Duty Auto Drain for Medium Air Pressure, Option 2: -
Size: 6 [0.82m³/min (ANR), 28.96scfm], Voltage: 20 [200VAC (50Hz), 200/220VAC (60Hz), Single Phase], Option 1: Heavy Duty Auto Drain for Medium Air Pressure, Option 2: R+T
Size: 6 [0.82m³/min (ANR), 28.96scfm], Voltage: 20 [200VAC (50Hz), 200/220VAC (60Hz), Single Phase], Option 1: Motor Type Auto Drain, Option 2: -
Size: 4 [0.57m³/min (ANR), 20.13scfm], Voltage: 20 [200VAC (50Hz), 200/220VAC (60Hz), Single Phase], Option 1: Cool Compressed Air Output, Option 2: Terminal Block for Run & Alarm Signal
Size: 6 [0.82m³/min (ANR), 28.96scfm], Voltage: 20 [200VAC (50Hz), 200/220VAC (60Hz), Single Phase], Option 1: Cool Compressed Air Output, Option 2: -
Size: 4 [0.57m³/min (ANR), 20.13scfm], Voltage: 20 [200VAC (50Hz), 200/220VAC (60Hz), Single Phase], Option 1: Cool Compressed Air Output, Option 2: -
Size: 11 [1.82m³/min (ANR), 64.27scfm], Voltage: 20 [200VAC (50Hz), 200/220VAC (60Hz), Single Phase], Option 1: A+C+L, Option 2: Terminal Block for Run & Alarm Signal
Size: 6 [0.82m³/min (ANR), 28.96scfm], Voltage: 20 [200VAC (50Hz), 200/220VAC (60Hz), Single Phase], Option 1: None, Option 2: Terminal Block for Run & Alarm Signal
Size: 8 [1.32m³/min (ANR), 46.62scfm], Voltage: 20 [200VAC (50Hz), 200/220VAC (60Hz), Single Phase], Option 1: Cool Compressed Air Output, Option 2: -