Fluid temperature and ambient temperature ranges are; 0 to 40C for ionizer, 0 to 50C for feedback sensor and auto balance sensor (high accuracy type), 0 to 40C for AC adapter, and 0 to 45C for remote controller. Do not use the sensor in locations where the temperature may change suddenly even if the ambient temperature range is within the specified limits, resulting in condensation. 2.
Operate in an ambient temperature range between 0C and 50C. 3. Operate in an ambient humidity range between 45% to 80% (no condensation). 18 These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of Caution, Warning or Danger.
Coolant (water-soluble) Compatibility with polyester: OK Compatibility with stainless steel 304: OK Compatibility with NBR (FKM): OK 50C 80C or less: OK 0.3 MPa 0.5 MPa or less: OK Check the compatibility of fluid with vessel material [stainless steel 304/ carbon steel].
During operation: 36F (2C) to 113F (45C) During storage: 32F (0C) to 122F (50C) (when there is no drain water inside of the piping) Avoid locations where temperature substantially changes. Avoid locations where strong magnetic noise occurs. (Avoid locations where strong electric fields, strong magnetic fields, or surge voltages occur.)
Specifications Valve construction Rubber seal Fluid Air Maximum operating pressure 0.7 MPa Valve specifications Min. operating pressure Single 0.15 MPa Double (Double solenoid) 0.1 MPa 3 position 0.2 MPa Ambient and fluid temp. 10 to 50C Note 1) Lubrication Not required Pilot valve manual override Push type/Locking type (Tool required) Vibration/Impact resistance Note 2) 30/150 m/s2 Protection
ATEX Compliant 5 Port Solenoid Valve Series 52-SY II 2G Ex ia IIC T4...T5 II 2G Ex ia IIC T6 Gb Ta10C to 50C Gb Ta10C to 45C 0344 How to order 01 F 3 52 SY L 1 5 2 0 Bracket ATEX category 2 Without bracket With foot bracket Note 1) Nil F1 F2 With side bracket Series Note 1) 2 position single solenoid valve only.
TT-type is connected to the terminal block.Use only supplied cable and nut. 2 Series 53-SY5000/7000/9000 Specifications 53-SY9000 53-SY5000 53-SY7000 Series Fluid Air 2-position single 4-position dual 3 port valve 20 to 100 psi (0.15 to 0.7 MPa) Internal pilot operating pressure range 2-position double 15 to 100 psi (0.1 to 0.7 MPa) 3-position 30 to 100 psi (0.2 to 0.7 MPa) 15 to 120F (10 to 50C
ARP30-02BG-3 1.4 L/min (ANR) or less (at P2 = 0.6 MPa) Pressure port size Note 3) 1/8 1/4 1/8 5 to 60C (No freezing) Ambient and fluid temperature With digital pressure switch 5 to 50C (No freezing) Ex.)
ARP30-02BG-3 1.4 L/min (ANR) or less (at P2 = 0.6 MPa) Pressure port size Note 3) 1/8 1/4 1/8 5 to 60C (No freezing) Ambient and fluid temperature With digital pressure switch 5 to 50C (No freezing) Ex.)
Size: 25, Motor Mounting: D (In-line Type), Motor Type: Step Motor, Servo/24 VDC, Lead: B (LEY25, 6; LEY32/40, 8), Stroke: 50mm, Motor: B (w/Lock), Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut Included), Mounting: Ends Tapped, Body Bottom Tapped, Actuator Cable Length: 5m, Controller Type (LEC, JXC): C91 (JXC91, EtherNet/IPâ„¢ Direct Input Type), I/O Cable Length for LEC: w/o Cable
Size: 32, Motor Mounting: D (In-line Type), Motor Type: Step Motor, Servo/24 VDC, Lead: B (LEY25, 6; LEY32/40, 8), Stroke: 50mm, Motor: B (w/Lock), Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut Included), Mounting: Ends Tapped, Body Bottom Tapped, Actuator Cable Length: 5m, Controller Type (LEC, JXC): C91 (JXC91, EtherNet/IPâ„¢ Direct Input Type), I/O Cable Length for LEC: w/o Cable
Size: 40, Motor Mounting: D (In-line Type), Motor Type: Step Motor, Servo/24 VDC, Lead: B (LEY25, 6; LEY32/40, 8), Stroke: 30mm, Motor: w/o Lock, Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut Included), Mounting: Ends Tapped, Body Bottom Tapped, Actuator Cable Length: 5m, Controller Type (LEC, JXC): C91 (JXC91, EtherNet/IPâ„¢ Direct Input Type), I/O Cable Length for LEC: w/o Cable
Size: 32, Motor Mounting: D (In-line Type), Motor Type: Step Motor, Servo/24 VDC, Lead: C (LEY25, 3; LEY32/40, 4), Stroke: 30mm, Motor: B (w/Lock), Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped, Body Bottom Tapped, Actuator Cable Length: 5m, Controller Type (LEC, JXC): C91 (JXC91, EtherNet/IPâ„¢ Direct Input Type), I/O Cable Length for LEC: w/o Cable, Controller Mounting: 8
Size: 25, Motor Mounting: D (In-line Type), Motor Type: Step Motor, Servo/24 VDC, Lead: B (LEY25, 6; LEY32/40, 8), Stroke: 200mm, Motor: B (w/Lock), Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped, Body Bottom Tapped, Actuator Cable Length: 5m, Controller Type (LEC, JXC): C91 (JXC91, EtherNet/IPâ„¢ Direct Input Type), I/O Cable Length for LEC: w/o Cable, Controller Mounting:
Series: 11-LEFS (Clean Series Ball Screw Drive), Accuracy: Basic Type, Size: 40, Motor Type: Step Motor (Servo/24 VDC), Lead: A (LEFS16, 10mm; LEFS25, 12mm; LEFS32, 16mm; LEFS40, 20mm), Stroke: 600mm, Motor Option: w/o Lock, Vacuum Port: Left, Positioning Pin Hole: Housing B Bottom, Actuator Cable Type: R [Robotic Cable, (Flexible Cable)], Actuator Cable Length: 5 (5m), Controller Type: C
Series: 11-LEFS (Clean Series Ball Screw Drive), Accuracy: H (High Precision Type), Size: 16, Motor Type: Step Motor (Servo/24 VDC), Lead: A (LEFS16, 10mm; LEFS25, 12mm; LEFS32, 16mm; LEFS40, 20mm), Stroke: 50mm, Motor Option: w/o Lock, Vacuum Port: Left, Positioning Pin Hole: K (Body Bottom, 2 Locations), Actuator Cable Type: R [Robotic Cable, (Flexible Cable)], Actuator Cable Length: 5
Series: 11-LEFS (Clean Series Ball Screw Drive), Accuracy: H (High Precision Type), Size: 25, Motor Type: Step Motor (Servo/24 VDC), Lead: A (LEFS16, 10mm; LEFS25, 12mm; LEFS32, 16mm; LEFS40, 20mm), Stroke: 100mm, Motor Option: w/o Lock, Vacuum Port: Left, Positioning Pin Hole: K (Body Bottom, 2 Locations), Actuator Cable Type: R [Robotic Cable, (Flexible Cable)], Actuator Cable Length: 5
Series: 11-LEFS (Clean Series Ball Screw Drive), Accuracy: Basic Type, Size: 16, Motor Type: Step Motor (Servo/24 VDC), Lead: A (LEFS16, 10mm; LEFS25, 12mm; LEFS32, 16mm; LEFS40, 20mm), Stroke: 300mm, Motor Option: w/o Lock, Vacuum Port: Left, Positioning Pin Hole: Housing B Bottom, Actuator Cable Type: R [Robotic Cable, (Flexible Cable)], Actuator Cable Length: 5 (5m), Controller Type: C
Series: 11-LEFS (Clean Series Ball Screw Drive), Accuracy: H (High Precision Type), Size: 40, Motor Type: Step Motor (Servo/24 VDC), Lead: A (LEFS16, 10mm; LEFS25, 12mm; LEFS32, 16mm; LEFS40, 20mm), Stroke: 900mm, Motor Option: w/o Lock, Vacuum Port: Left, Positioning Pin Hole: Housing B Bottom, Actuator Cable Type: R [Robotic Cable, (Flexible Cable)], Actuator Cable Length: 5 (5m), Controller
Series: 11-LEFS (Clean Series Ball Screw Drive), Accuracy: H (High Precision Type), Size: 32, Motor Type: Step Motor (Servo/24 VDC), Lead: A (LEFS16, 10mm; LEFS25, 12mm; LEFS32, 16mm; LEFS40, 20mm), Stroke: 250mm, Motor Option: B (w/Lock), Vacuum Port: R (Right), Positioning Pin Hole: Housing B Bottom, Actuator Cable Type: R [Robotic Cable, (Flexible Cable)], Actuator Cable Length: 5 (5m)