No lubrication is required. 3 port pilot operated poppet valve , Material restriction type , Low power consumption: 4.8W DC (standard type); 2W DC (energy-saving type) , Possible to use in vacuum or under low pressure, Poppet type valve, 3 PORT SOLENOID VALVE, I58, 1 lb
No lubrication is required. 3 port pilot operated poppet valve , Material restriction type , Low power consumption: 4.8W DC (standard type); 2W DC (energy-saving type) , Possible to use in vacuum or under low pressure, VALVE, 3 PORT SOLENOID VALVE, I58, 1 lb
Load voltage Lead wire length (m) * Auto switch model Indicator light Type Electrical entry Wiring (output) Electrical entry direction Special function Applicable load 0.5 (Nil) 3 (L) 5 (Z) AC DC Perpendicular In-line IC circuit IC circuit 3-wire (NPN equiv) Z76 5V Reed switch Yes Grommet 100V 12V Z73 Relay, PLC 24V 2-wire No 100V or less 5V, 12V Z80 3-wire (NPN) Y69A Y59A IC circuit 5V
Load voltage Auto switch model Lead wire length [m] Pre-wired connector Applicable load DC AC Perpendicular In-line 0.5 (Nil) 1 (M) 3 (L) 5 (Z) None (N) Indicator light Type Special function Electrical entry Wiring (Output) M9NV M9N IC circuit 3-wire (NPN) 5 V, 12 V Solid state auto switch 3-wire (PNP) M9PV M9P 2-wire 12 V M9BV M9B 3-wire (NPN) 5 V, 12 V M9NWV M9NW IC circuit 3-wire (PNP)
Lead wire length (m) Indicator light Indicator light Auto switch model Pre-wire connector Applicable load Perpendicular In-line Load voltage Electrical entry Special function Wiring (Output) Type 0.5 (Nil) 3 (L) 5 (Z) DC AC A96V A93V M9NV M9PV M9BV F9NWV F9PWV F9BWV A96 A93 M9N M9P M9B F9NW F9PW F9BW 3-wire (NPN equivalent) 2-wire 3-wire (NPN) 3-wire (PNP) 2-wire 3-wire (NPN) 3-wire (PNP)
AL13 High compressor discharge pressure AL15 Refrigeration circuit pressure (high pressure side) drop AL16 Refrigeration circuit pressure (low pressure side) rise Code Alarm message AL17 Refrigeration circuit pressure (low pressure side) drop AL18 Compressor running failure AL19 Communication error AL20 Memory error AL21 DC line fuse cut AL22 Circulating uid discharge temp. sensor failure
If the pressure differential at each port exceeds the values in the table below, valve leakage may occur. 2 Standard coil Coil with power-saving circuit DC circuit 1 1 (+, ) Red (+) Power-saving circuit 2 Port Valve SOL. SOL. Max. operating pressure differential (MPa) Orifice diameter (mm ) Model 2 (, +) Black () Pressure port 1 2. Apply the correct voltage.
Basic type Pilot Solenoid Valve Specifications VEX5511/5711/5911/5501/5701/5901 SF4--20 Grommet (G), Grommet terminal (E), Conduit terminal (T), DIN terminal (D) Pilot valve Model Electrical entry Coil rated voltage (V) AC (50/60Hz) DC Allowable voltage 100 V, 200 V, Other (Option) 24 V, Other (Option) 15 to +10% of rated voltage Inrush AC Holding DC 5.6 VA (50Hz), 5.0 VA (60Hz) 3.4 VA (50Hz
1021Series VQ1000 Base Mounted Plug-in Unit Note) For CE compliant models, DC-type only. [Option] How to Order Manifold VV5Q 1 1 08 C6 U1 F 10 CE compliant Series Nil CE compliant VQ1000 1 Q Note) For CE compliant models, DC-type only.
AC Lead wire length (m) Load voltage DC Auto switch model Special function Electrical entry Indicator light Wiring (Output) Pre-wired connector Applicable load Type In-line Perpendicular 0.5 (Nil) 1 (M) 3 (L) 5 (Z) M9NV M9PV M9BV M9NWV M9PWV M9BWV M9NAV M9PAV M9BAV M9N M9P M9B M9NW M9PW M9BW M9NA M9PA M9BA 5 V, 12 V 3-wire (NPN) 3-wire (PNP) IC circuit Solid state switch 12 V 2-wire 3-wire
Having the amplifier built into the electro-pneumatic pilot valve, only an external (24V DC) power supply and (1 to 5V DC) signal voltage need to be connected making handling simple.
Available in standalone or manifold configurations.Vacuum ejector with valve and switch (metric) , Nozzle diameters: .5mm, .7mm, 1mm, 1.3mm and 1.5mm , Body styles with or without valve , Various lead wire and connector options , Various vacuum switch models , Various vacuum switch electrical entry options, VACUUM GENERATOR,HIGH PRESS/DC, VACUUM SERIES, ZM VACUUM SYSTEM, DC, ZM NOZZLE
The SQ plug lead units are available with D-sub connector, flat ribbon cable connector or PC wiring system compatible flat ribbon cable kits.Fluid: Air/inert gas , Maximum operating pressure: 0.7MPa , Effective area mm (Cv factor):0.40 to 0.71, Coil rated voltage: 12, 24VDC , Power consumption (current): 24VDC; 0.4W DC (17mA), 12VDC; 0.4W DC (34mA) , Ambient and fluid temperature: -10 to
No lubrication is required. 3 port pilot operated poppet valve , Material restriction type , Low power consumption: 4.8W DC (standard type); 2W DC (energy-saving type) , Possible to use in vacuum or under low pressure, Poppet type valve, 3 PORT SOLENOID VALVE, I58, 1.00000 lb
No lubrication is required. 3 port pilot operated poppet valve , Material restriction type , Low power consumption: 4.8W DC (standard type); 2W DC (energy-saving type) , Possible to use in vacuum or under low pressure, Poppet type valve, 3 PORT SOLENOID VALVE, I58, 1.00000 lb
No lubrication is required. 3 port pilot operated poppet valve , Material restriction type , Low power consumption: 4.8W DC (standard type); 2W DC (energy-saving type) , Possible to use in vacuum or under low pressure, Poppet type valve, 3 PORT SOLENOID VALVE, I58, 1.00000 lb
Having the amplifier built into the electro-pneumatic pilot valve, only an external (24V DC) power supply and (1 to 5V DC) signal voltage need to be connected making handling simple.
Having the amplifier built into the electro-pneumatic pilot valve, only an external (24V DC) power supply and (1 to 5V DC) signal voltage need to be connected making handling simple.
The SQ plug lead units are available with D-sub connector, flat ribbon cable connector or PC wiring system compatible flat ribbon cable kits.Fluid: Air/inert gas , Maximum operating pressure: 0.7MPa , Effective area mm² (Cv factor):0.40 to 0.71, Coil rated voltage: 12, 24VDC , Power consumption (current): 24VDC; 0.4W DC (17mA), 12VDC; 0.4W DC (34mA) , Ambient & fluid temperature: -10 to 50
The SQ plug lead units are available with D-sub connector, flat ribbon cable connector or PC wiring system compatible flat ribbon cable kits.Fluid: Air/inert gas , Maximum operating pressure: 0.7MPa , Effective area mm² (Cv factor):0.40 to 0.71, Coil rated voltage: 12, 24VDC , Power consumption (current): 24VDC; 0.4W DC (17mA), 12VDC; 0.4W DC (34mA) , Ambient & fluid temperature: -10 to 50