Body/Exhaust Type: G (Single Unit - High-noise Reduction Silencer Exhaust), Nominal Nozzle Size: 10 (ø1.0), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: K (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / NPN 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 06 [ø6
Body/Exhaust Type: G (Single Unit - High-noise Reduction Silencer Exhaust), Nominal Nozzle Size: 15 (ø1.5), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: K (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / NPN 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 06 [ø6
Body/Exhaust Type: A (Single Unit - Silencer Exhaust), Nominal Nozzle Size: 15 (ø1.5), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: K (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / NPN 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 08 [ø8 One-touch Fitting (
Body/Exhaust Type: B (Single Unit - Port Exhaust), Nominal Nozzle Size: 15 (ø1.5), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: K (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / NPN 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 07 [ø1/4 One-touch Fitting (Inch
(Example: If the Pressure switch with output impedance of 1k is connected to the A/D converter to detect the analogue output of 5 V, the detected voltage by the A/D converter becomes 5(V) 1(M)/(1(k) + 1(M)) 4.995(V), and there is an error of approximate 0.005 V.) Output impedance R The pressure range in which the Pressure switch satisfies the specifications.
U Min. bending radius of lead wire 10 Auto switch K M E J S B + Stroke L + Stroke L A + 2 strokes Note) The drawings above show type D-A7 and D-A8 reed switches. The values shown inside ( ) are for switches other than types D-A7 and D-A8. S and U dimensions for connector type auto switches (D-A7C, D-A80C, and D-J79C) are 7mm greater.
through 8-L counter bore 4-K through C B + Stroke J J 8-L counter bore A + Stroke M M CHKDB20 & 25 CHKDB32 to 100 Width across flats f c a b g e h + Stroke Rod end male thread (mm) F L A B C D E G H J K M P Q R Bore size (mm) 20 M8 x 1.25 9.5 depth 5.4 51 43 8 12 10 10 6 30 5.5 43 1/8 16.5 6 25 M10 x 1.5 9.5 depth 5.4 53 45 8 14 12 12 6 36 5.5 49 1/8 17 8 32 M12 x 1.75 11 depth 6.5 61 51
Body/Exhaust Type: B (Single Unit - Port Exhaust), Nominal Nozzle Size: 15 (ø1.5), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: K (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / NPN 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 07 [ø1/4 One-touch Fitting (Inch
Note 2) This filter does not include any companion flange, companion flange bolt, and O-ring. 4 x K depth L DRAIN (): Internal dimensions for FH342 type (mm) Model Weight (kg) d A B C D E F G H J J' K L M N P Q Threaded Rc Flange SSA FH340-03 FH340-04 FH342-06 FH342-08 FH34 -10 FH34 -12 FH341-16 FH440-03 FH44 -04 FH44 -06 FH44 -08 FH44 -10 FH44 -12 FH441-16 FH441-20 FH441-24 FH540-03 FH54
In-line type How to Order JIS Symbol 1F 12 K 400 AS Option Body size Nil K N None Hexagonal lock nut Electroless nickel plated If more than one option is required, write option part numbers in the order of K, N. M5 standard 1/8 standard 1/4 standard 3/8 standard 1/2 standard 100 200 205 300 400 Applicable tubing O.D.
JIS Symbol 15-9-19 2 Series AS How to Order 2 2 1 U02 06 K AS 1F Nil Option Body size 2 3 4 1/8, 1/4 standard 3/8 standard 1/2 standard None Hexagonal lock nut Electroless nickel plated K N If more than one option is required, write option part numbers in the order of K, N. Applicable tubing O.D.
C [dm3/(sbar)] b Cv C [dm3/(sbar)] b Cv VP517Y G3/8 8.8 0.14 2 8.2 0.15 1.8 VP717Y G1/2 13.8 0.11 2.9 12.9 0.18 2.9 2 VP500/700 Series Spacer Center of F.R.L. body D C B Model A B C D Y300-A 4.2 43.4 21.7 57.9 Y400-A 5.2 53 26.5 68.5 A (Spacer width) Seal Y400-A Spacer with Bracket D K Center of F.R.L. body J H F G E E C B Seal A (Spacer width) Y400T-A Model A B C D E F G H J K Y300T-A 4.2
Cushion seal L Guide gasket M Piston gasket Replacement Parts: Lock-up Unit K, L and M are non-replaceable parts, so they are not included in the seal kit. CL 40 TN Port thread type Bore size (mm) Nil Rc NPT G TN TF Consult with SMC when replacing the lock-up unit with a bore size of 125 to 160. 154
For the special wiring specification “-K,” single solenoids (1 point) and double solenoids (2 points) are allocated among the max. number of points.
Note) For the special wiring specification “-K,” a separate manifold specification sheet is required. It can be found here.
k=LECPA" target="_blank">here.
Type), 1st Nominal Nozzle Size: 1 (ø0.7), 1st Selection Supply Valve and Release Valve: K (N.C.
Adjusting Needle, Screwdriver Operation Type), 1st Nominal Nozzle Size: 2 (ø1.0), 1st Selection Supply Valve and Release Valve: K (N.C.
Body/Exhaust Type: H (For Manifold - High-noise Reduction Silencer Exhaust), Nominal Nozzle Size: 10 (ø1.0), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: K (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / NPN 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 07 [