Model: 40 (Standard), Bar Length: 22 (220mm), Emmiter Cartridge, Material: D (High Speed De-ionizing Cartridge, Tungsten), High-voltage Cable Length: 1 (1m), One-touch Fitting: 6H (ø6 Straight), Plug Position: Q (High-voltage Cable Side), Input, Output Specification: Nil (40); NPN (41, 42), Power Supply Cable Length: 3 (3m), Bar Bracket: B (w/Bracket 1)
Model: 40 (Standard), Bar Length: 28 (280mm), Emmiter Cartridge, Material: D (High Speed De-ionizing Cartridge, Tungsten), High-voltage Cable Length: 3 (3m), One-touch Fitting: BL (ø3/8" Elbow), Plug Position: Q (High-voltage Cable Side), Input, Output Specification: Nil (40); NPN (41, 42), Power Supply Cable Length: 3 (3m), Bar Bracket: B (w/Bracket 1), DIN Rail Bracket for Controller &
Model: 40 (Standard), Bar Length: 40 (400mm), Emmiter Cartridge, Material: D (High Speed De-ionizing Cartridge, Tungsten), High-voltage Cable Length: 3 (3m), One-touch Fitting: 7H (ø1/4" Straight), Plug Position: Q (High-voltage Cable Side), Input, Output Specification: Nil (40); NPN (41, 42), Power Supply Cable Length: 10 (10m), Bar Bracket: F (w/Bracket 2), DIN Rail Bracket for Controller
Model: 40 (Standard), Bar Length: 40 (400mm), Emmiter Cartridge, Material: D (High Speed De-ionizing Cartridge, Tungsten), High-voltage Cable Length: 3 (3m), One-touch Fitting: 7H (ø1/4" Straight), Plug Position: Q (High-voltage Cable Side), Input, Output Specification: Nil (40); NPN (41, 42), Power Supply Cable Length: 3 (3m), Bar Bracket: F (w/Bracket 2), DIN Rail Bracket for Controller
Model: 40 (Standard), Bar Length: 40 (400mm), Emmiter Cartridge, Material: D (High Speed De-ionizing Cartridge, Tungsten), High-voltage Cable Length: 3 (3m), One-touch Fitting: 7H (ø1/4" Straight), Plug Position: Q (High-voltage Cable Side), Input, Output Specification: Nil (40); NPN (41, 42), Power Supply Cable Length: 5 (5m), Bar Bracket: F (w/Bracket 2), DIN Rail Bracket for Controller
Model: 40 (Standard), Bar Length: 16 (160mm), Emmiter Cartridge, Material: S (Energy Saving High-efficiency Cartridge, Silicon), High-voltage Cable Length: 2 (2m), One-touch Fitting: 7H (ø1/4" Straight), Plug Position: Q (High-voltage Cable Side), Input, Output Specification: Nil (40); NPN (41, 42), Power Supply Cable Length: 3 (3m), Bar Bracket: B (w/Bracket 1)
Model: 40 (Standard), Bar Length: 34 (340mm), Emmiter Cartridge, Material: D (High Speed De-ionizing Cartridge, Tungsten), High-voltage Cable Length: 3 (3m), One-touch Fitting: 6H (ø6 Straight), Plug Position: Q (High-voltage Cable Side), Input, Output Specification: Nil (40); NPN (41, 42), Power Supply Cable Length: 3 (3m), Bar Bracket: B (w/Bracket 1), DIN Rail Bracket for Controller &
Model: 41 (AC), Bar Length: 46 (460mm), Emmiter Cartridge, Material: D (High Speed De-ionizing Cartridge, Tungsten), High-voltage Cable Length: 3 (3m), One-touch Fitting: BH (ø3/8" Straight), Plug Position: Q (High-voltage Cable Side), Input, Output Specification: Nil (40); NPN (41, 42), Power Supply Cable Length: 3 (3m), Bar Bracket: B (w/Bracket 1), DIN Rail Bracket for Controller &
Model: 40 (Standard), Bar Length: 28 (280mm), Emmiter Cartridge, Material: D (High Speed De-ionizing Cartridge, Tungsten), High-voltage Cable Length: 3 (3m), One-touch Fitting: 7H (ø1/4" Straight), Plug Position: Q (High-voltage Cable Side), Input, Output Specification: Nil (40); NPN (41, 42), Power Supply Cable Length: 3 (3m), Bar Bracket: B (w/Bracket 1), DIN Rail Bracket for Controller
Caution: SI unit for general purpose output block (EX500-Q 02 etc.) M3 x 18: 2 pcs. (Hexagon socket head cap screw (with SW)) : Please refer to the separate catalog regarding assembly and disassembly with other unit. Warning: WARNING indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury.
C/Q Lead wire and connector [dt2] Delay time setting 2 [0.00] 0.00 second DOWN button Blue L[CoL] Display colour setting 2 [1SoG] ON: Green OFF: Red Main display IO-Link status indicator light [F 3] [FiL] [FiL] Digital filter setting [1.0] 1.0 second [F 4] [PrS] [PrS] Auto-preset function setting [oFF] Manual Outline of Settings Item Description [F10] [FLo] [FLo] Display mode [inS] nstantaneous
/OUT2 White Not connected/Switch output 2 (SIO) If using the product in an interlocking circuit: Provide a double interlocking system, for example a mechanical system Check the product regularly for proper operation Otherwise malfunction can result, causing an accident. 3 LBlue 0 V 4 C/Q Black Communication data (IO-Link)/Switch output 1 (SIO) Main port Mountin Never mount the product in
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link
Rated Control Flow Range: 50 (0.5 to 50 L/min), Port Size: N1 (1/8 NPT), Input/Output Specification: 1 (Input: Analog 1 to 5 V, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 1 to 5V or 0 to 10V), Wire Connector: Q (M12-M12 lead wire with connector (3 m/5 core)), Unit Specification: Unit Specification, Bracket: R (Bracket (mounting position: Side)
System: Q (Vacuum Pump System for Manifold), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs), Connector: C (Common Wiring, Plug-in for Manifold), Vacuum, V Port: 07 (Inch Size, ø1/4" One-touch Fitting), Bracket: w/o Option, Pump System PE Port Female Thread: w/o Option, Individual
Rated Flow Range: 10 (0.1 to 10 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: N1 (NPT1/8), Output Specification: L4 (Out 1: IO-Link or NPN/PNP, Out 2: Analog 4 to 20 mA), Lead Wire: Q (w/M12 Conversion Lead Wire and Connector, 0.1m)
Model: 40 (Standard), Bar Length: 28 (280mm), Emmiter Cartridge, Material: D (High Speed De-ionizing Cartridge, Tungsten), High-voltage Cable Length: 3 (3m), One-touch Fitting: 7H (ø1/4" Straight), Plug Position: Q (High-voltage Cable Side), Input, Output Specification: Nil (40); NPN (41, 42), Power Supply Cable Length: 3 (3m), Bar Bracket: w/o Bracket, DIN Rail Bracket for Controller & <
Model: 42 (Dual AC), Bar Length: 46 (460mm), Emmiter Cartridge, Material: D (High Speed De-ionizing Cartridge, Tungsten), High-voltage Cable Length: 3 (3m), One-touch Fitting: 6H (ø6 Straight), Plug Position: Q (High-voltage Cable Side), Input, Output Specification: Nil (40); NPN (41, 42), Power Supply Cable Length: 3 (3m), Bar Bracket: B (w/Bracket 1), DIN Rail Bracket for Controller & <
Model: 40 (Standard), Bar Length: 16 (160mm), Emmiter Cartridge, Material: L (High Energy Saving De-ionizing Cartridge, Tungsten), High-voltage Cable Length: 3 (3m), One-touch Fitting: 6H (ø6 Straight), Plug Position: Q (High-voltage Cable Side), Input, Output Specification: Nil (40); NPN (41, 42), Power Supply Cable Length: 3 (3m)