SMC Corporation of America
Elite Part Number Search
Search Results "VV2Q22-16-00N"

MHC2-16 MHC2-10 MHC2-20 MHC2-25 !8 !9 NBR MHC10-PS MHC16-PS MHC20-PS MHC25-PS Seal kit @0 @1 2.6-5

Refer to pages 16 through 18 for safety instructions, actuator precautions and auto switch precautions. Mounting Selection Handling of Adjuster Options 3. Please observe the specified torque limits when tightening screws to mount the attachment.

2 2-4.5 (Mounting hole) P mPm P 19 35 Pg.7 2-Rc 1/8 1(P) port A A A 11 20 26 49 300 (lead wire length) 1 P = 19 13.5 L2 5.5 L1 47.5 11 5 n-Rc 1/8, M5 x 0.8 2(A) port 19 35 n-Rc 1/8 3(R) port 47.5 11 R R P = 19 19 L Dimension n: Stations n L 1 38 27 2 57 46 3 76 65 4 95 84 5 114 103 6 133 122 7 152 141 8 171 160 9 190 179 10 209 198 11 228 217 12 247 236 13 266 255 14 285 274 15 304 293 16

Y: 172.9 Y: 4.5 to 7 D: 6 to 8 81.5 MAX.10 D: 173.4 33.5 32.5 24 16 (P port) Rc 3/8, 1/2 Pg9 Y: 110.2 127.2 D: 108.2 125.2 D: 99.2 116.2 Y: 101.2 118.2 : With light/surge voltage suppressor ( ): Dimensions for external pilot 4-8-11 12 Series VP300/500/700 Manifold Specifications Specifications Piping is concentrated at the base side. All external pilots are gathered in the base.

For IRV2000, IRV3000 Zero position Heaven Zero position Ground Fig. (2) Fig. (1) 14-5-16 16 Vacuum Regulator Series IRV1000/2000/3000 Standard Specifications F.R.L.

Recommended tightening torque is between 3 and 4 Nm for R 1/16 and 7 and 9 Nm for R 1/8. Note 2) Water cannot be used as an operating fluid. Because the clearance gap of the air passage of the Bourdon tube is very small. Water will block the gap and cause a malfunction.

VBA4 The required time to increase tank pressure from 0.8 MPa to 1.0 MPa at 0.5 MPa supply pressure is calculated as follows. 1.0 0.5 = = 2.0 P2 P1 P2 P1 P2 P1 0.8 0.5 = = 1.6 P2 P1 1.5 0.5 = = 3.0 1.0 0.5 = = 2.0 0.8 0.5 = = 1.6 P2 P1 P2 P1 With the pressure increase ratio from 1.6 to 2.0, the time of 65 16 = 49 sec. (t) is given for 10 l tank by the graph.

W (44) (Y) Z (X) (V) T R T 25 IN port 23/8 l =280 l =300 : Thread type 2.5 (N) E Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com A (U) S Q D G C C B L1 L2 L3 16 D side U side Stations 1 2 3 4 5 n 21 5.5 16 OUT port n-1/4 H H P = J (Pitch) 2 n-1/8 : Thread type L Dimension

Refer to pages 17-2-72/73 regarding manifold additions. 17-2-69 10 Series VDW10/20/30 Dimensions VV2DW2 (25.5) 16 1 4.6 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 16 300 11 1 24 33 19.5 (19.5) (: Thread type) 21/4 (IN port) R2.3 4.5 9 L1 L2 L3 1 Stations D side

VNH1 VNH2 VNH3 VNH4 Description Bracket (With bolt and washer) B VNH1-16 VNH2-16 VNH3-16 VNH4-16 How to Order Pilot Solenoid Valves VO301-00 T X302 Light/surge voltage suppressor Rated voltage Nil S Z L With indicator light None With surge voltage suppressor With light/surge voltage suppressor 2 200 VAC 50/60 Hz 1 100 VAC 50/60 Hz 3 110 VAC 50/60 Hz 4 220 VAC 50/60 Hz 5 24 VDC 6 12 VDC 7

Proof pressure Max. operating pressure Set press. range Air operated Solenoid Ambient and fluid temperature Hysteresis Repeatability Sensitivity Mounting Lubrication Port 01 P A R mm2 02 01 02 03 04 04 06 10 10 12 14 20 02 Port size Rc(PT) 1 11 2 1 4 11 4 1 2 1 8 1 4 1 8 1 4 1 4 3 8 1 2 1 2 3 4 590 2 1 300 17 25 1.4 16 0.9 25 1.4 60 3.3 70 3.9 330 18 36 2.0 Cv 16 0.9 130 7.2 160 8.9 180 10

Applicable filter model Element size (mm) Principal Parts Material ZFC100 12 x 8 x L20 I-62S-A ZFC101 Material Description Case ZFC200 16 x 12 x L25 I-63S-A Special clear nylon ZFC201 Cover PBT Note) Spare elements and O-rings for the cover are sold in sets of 10 pieces each.

Vacuum Pressure Switch: ZSE2-0R-15 ZSE2-0R-15 ZSE2-0R-15L ZSE2-0R-15C ZSE2-0R-15CL ZSE2-0R-15CN Indicator light (Red) Pressure setting trimmer Indicator light (Red) Pressure setting trimmer H L SET L SET H 15 15 9 9 2-M2.5 Mounting thread 2-M2.5 Mounting thread 25 25 31 31 600(3000) 42 600(3000) 49.5 40 40 3 3 20 20 18 18 16 16 13 11 13 11 9 9 Vacuum supply port 3.3 Vacuum supply port 3.3

s o.50 o.8e4 o93 0.75 0.18 %-18 0.50 0.95 2.94 106 (1 0.312 %-24 0.50 o.624 0.25 1.12 o.12 0.88 0.88 0.24 %-8 0.62 1.17 3.25 0.la7 Wzo 0.75 0.7i19 o 1.t2 0.25 1.06 'L06 o.25 %-16 ora 1.62 400 150 t1%l o.87 1h-20 o_75 o.749 0.38 1.56 0.25 1.25 1.25 o.25 3l-16 0.88 '1.50 3.69 Double End : NC.

Blue DC () OFF SE1(L)-16, -17 I Z Atmospheric pressure 0 Brown DC (+) How to Use Connector Black OUT1 LED Red 1. Attaching and detaching connectors When assembling the connector to the switch housing, push the connector straight onto the pins until the lever locks into the housing slot.

Air Slide Table Series MXW How to Order MXW 16 100 B M9BW Made to Order Refer to page 151 for details. Port thread type 8 to 16 M thread Rc NPT G Nil Number of auto switches Nil TN TF 20, 25 2 pcs. 1 pc. n pcs.

.: CompoBus/S (16 outputs) OMRON Corp.: CompoBus/S (8 outputs) SUNX Corp.: S-LINK (16 outputs) SUNX Corp.: S-LINK (8 outputs) NKE Corp.: Uni-wire System NKE Corp.: Uni-wire H System Note 1) DN1s occupied points are 16 inputs and 16 outputs, while DN1-X26 has 0 inputs and 16 outputs. Note 2) Please consult SMC for networks other than those mentioned above. 1650

D 16 inputs M12 connector (5 pins) 8 pcs. E 16 inputs D-sub connector (25 pins) F 16 inputs Spring type terminal block (32 pins) For specications, refer to the Fieldbus system EX600 series in the Web Catalog.

Pressure Gauge for General Purpose Series G15/G27 Standard Specifications G15 G27 Model Back side thread Type 1 8 R 1 16 Port size (1) R : M5 (Female thread) G Fluid (2) Air Indication precision 5% F.S.

Bellows assembly for ISG 110-030 16-9-6