Series: 25A-ISE20, Rated Pressure Range: C (-0.1 to 1 MPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specifications: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: D (Panel
Particle diameter (m) Particle diameter (m) Front matter 23 Comparison of Cleanliness Standards ISO 14644-1 ISO Cass 1 to 9 Intermediate classes available U descriptor: Particles smaller than 0.1 m M descriptor: Particles larger than 5.0 m Standard Fed.Std.209E British unit: Class 1 to 100.000 SI unit: Class M1 to M7 U descriptor: Particles diameter smaller than 0.1 m (SI unit) (British
min 216 L/min 540 L/min 10100 L/min 50250 L/min 3.555.0 L/min ( 3.5 L/min 0.0) 1.722.0 L/min ( 1.7 L/min 0.0) 0.355.50 L/min ( 0.35 L/min 0.00) 20350 L/min ( 20 L/min 0) 7140 L/min ( 7 L/min 0) 0.355.50 L/min 1.722.0 L/min 3.555.0 L/min 7140 L/min 20350 L/min 0.01 L/min 0.1 L/min 1 L/min 2 L/min (50 ms) 0.05 L/pulse 0.1 L/pulse 0.5 L/pulse 1 L/pulse 2 L/pulse 090 () 070 ( ) L/minL
Lube Unit/ALDU600-06 to 10, ALDU900-12 to 20 Float switch mounting position Mounting thread M12 R 3.2 S 40 Q IN P M N M L A B C E E F G K J (Bracket mounting dimensions) H D S Bracket (Option) Panel (Option) 6 x 17 A B C D E F G H J K L M N P Q R S Model Port size ALDU600-06 ALDU600-10 ALDU900-12 ALDU900-14 ALDU900-20 289 291.2 453 453 476 24.5 13.6 51 45.5 14.5 69.5 78.2 89 94.5 102.5 4
0.05 MPa 1.5 MPa 5 to 60C 0.01 m (95% particle size collection) Oil mist removal rate Less than 3.5 particles 0.3 m or larger per liter of air (100 particles or less per cubic foot) Series AME should be installed on the inlet side.)
L M a l e E l b o w . . . . . . L__ Plug-in Elbow .. ... L Union Elbow . . . . . . LF Female Elbow . K 45" Male Elbow . . . KF 45' Female Elbow Y M a l e R u n T e e . . . . . T Male Branch Tee . , T Union Tee , . . . . . . , TF Female Branch Tee E Bulkhead Connector E Bulkhead Union . . , U Male Branch 'Y" . . . U Union "Y" . . . . . . . .
Without bracket Air pressure supply (P) port Thread size: Q 45 45 Fluid passage dia.: P R J K 2 x L H I O 4 x Sa Thread depth Sb G M N A D F Vacuum flow Dust bag When dust bag is mounted E T Suction air Suction air Discharge air B C C U Hose band V Note 1) (mm) A 158 B 70 C 50 D 20 E F 24.5 G 60.5 H 5 I 70 J 60 K 5.5 L 72 M 37 N 2 O 30 P Rc1/4 Q R 59 Sa Sb T 500 U 250 V 310 Model ZH30--X185
Power supply 20 3-phase 200 VAC (50 Hz) 3-phase 200 to 230 VAC (60 Hz) Specications Model HRSH100-Al-20-l HRSH150-Al-20-l HRSH200-Al-20-l HRSH250-Al-20-l HRSH300-Al-20-l Cooling method Air-cooled refrigeration Refrigerant R410A (HFC) Refrigerant charge kg 1.27 2.1 2.1 2.8 2.8 Control method PID control Ambient temperature/Altitude Note 1), 9) C Temperature: 20 to 45, Altitude: less than 3000
Lead wire length 0.5 m Nil (Example) A54 3 m L (Example) A54L 5 m Z (Example) A54Z In addition to the models in the above table, there are some other auto switches that are applicable.
indication (2-color indicator) 2-wire 3-wire (PNP) 12 V 3-wire (NPN) 3-wire (PNP) IC circuit With timer 5 V,12 V 3-wire IC circuit E76A 5 V (NPN equivalent) Yes Grommet E73A E80A 24 V 12 V 5 V,12 V 100 V 2-wire Relay, PLC IC circuit N0 100 V or less Lead wire length symbols: 0.5 mNil (Example) M5BW 3 m L (Example) M5BWL 5 m Z (Example) M5BWZ Solid state auto switches marked with are produced
Nil (Example) C73C 3 m L (Example) H73CL 5 m Z (Example) C73CZ None N (Example) C73CN Since there are other applicable auto switches than listed, refer to page 9-4-10 for details.
Specifications Allowable Moment/Maximum Load Mass Allowable moment (Nm) Max. load mass (kg) Bore size (mm) 15 32 Bore size (mm) Model Air and inert gases Fluid M M M m Double acting Action 15 32 0.3 3 0.6 4 0.3 3 1 5 CYP 0.5MPa Proof pressure 0.05 to 0.3MPa Operating pressure range Note) Since the limit values for maximum load mass and allowable moment differ depending on conditions such
Applicable Auto Switches: Lead wire length (m) Auto switch type Load voltage Indicator light Applicable load Type Electrical entry Wiring (output) Special function 0.5 (Nil) 3 (L) 5 (Z) Tie-rod mount Band mount AC DC PLC A56 A53 5V 12V IC circuit B53 3-wire (NPN equiv.)
Nil (Example) C73C 3 m L (Example) H73CL 5 m Z (Example) C73CZ None N (Example) C73CN Since there are other applicable auto switches than listed, refer to page 9-4-10 for details.
PNP 1~5 V F PNP 4~20 mA G NPN H PNP J 1~5 V 1~5 V K 4~20 mA 4~20 mA OUT2 C (1) T V + (2m) N M L/min L G gal/min gal F gal/min gal J L/min L GFJ : 1[L/min]0.2642[gal/min] 1[gal/min]3.785[L/min] []=9/5[]+32 15 V PF3W5--1(T) -9No.PF-OMN0011CN-C C (1 ) T V -10No.PF-OMN0011CN-C / ZS-26-B ZS-26-C ZS-26-01 ZS-40-W 2 m (e-con) ZS-28-CA-4 1 ZS-40-Y 10 -11No.PF-OMN0011CN-C
Furthermore, if the cable length exceeds 5 m, then it will decrease by up to 10% for every additional 5 m.(If cable length is 15m: Maximum 20% reduction.)
No. 1 1 1 1 1 M3 M3 M3 M3 1/4 0.4~0.5Nm 2 2 2 2 M5 M5 M5 M5 1/6~1/4 1~1.5Nm 1) 1) 1) 1) ISO VG32 (MSDS) 6 No.VP300-OMP0001 VP Series VP Series VP Series VP Series 3 3 3 3 / / / / ( ( ( ( ) ) ) ) ( ( ( ( ) ) ) ) 30 () 1 ()ISO VG32 2 ()ISO VG32 IP65 (IEC60529) IP65 7 No.VP300-OMP0001 VP Series VP Series VP Series VP Series/ / / / L L L L /M /M /M /M 3.2~3.7mm () (+-) () (1mm
Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com VX3 L L VXA K VN K Conduit terminal: T LVC LVA F (Q) 34 LVH LVD LVQ 25 U LQ R C LVN G1/2 TI/ TIL E B A H D 2-P Port size (S) PA 2-M Thread depth N PAX L PB K N.C.
Port size 2-M Thread depth N L L K K Conduit terminal: T F (Q) 34 25 U R C G (PF) 1/2 E B A H D 2-P Port size (S) 2-M L K N.C.