With mounting threads on the bottom Low power consumption type 0.8 W (Held at 24 VDC) Low power consumption type 0.8 W (Held at 24 VDC) VDC) VX23: 11.5 W 10.5 W VX22: 8 W 7 W Reduction of power consumption (DC specification) VX21: 6 W 4.5 W For orifice sizes 2, 3, 4.5, and 6 Installation example Bracket High Vacuum Angle Valve Made of Aluminum Body, Plate: PEEK Diaphragm: EPDM/FKM/FFKM
Type without unit switching function is fixed SI units (l/min, or l, m3, m3 x 103). w e Unit display/Orange Flow rate confirmation display/Orange t u r The blinking intervals change depending on the flow rate value. U P S E T MODE DOWN Use to change the mode or to increase the set value. UP button ( button) t y u i Use to select the function.
With lock at double ends CBM2-20-PS-W CBM2-25-PS-W CBM2-32-PS-W CBM2-40-PS-W 20 25 32 40 CBM2-20-PS-W CBM2-25-PS-W CBM2-32-PS-W CBM2-40-PS-W Set of left nos. @6, @7. Seal kit includes @6 and @7. Order the seal kit, based on each bore size. (Except #3.) Seal kit includes a grease pack (10 g). Order with the following part number when only the grease pack is needed.
used STX ETX ACK NAK ASCII code 30H 31H 32H 33H 34H 35H 36H 37H 38H 39H Number used 0 1 2 3 4 5 6 7 8 9 ASCII code 2DH 20H Number used SP Space Minus ASCII code 41H 42H 43H 44H 45H 46H 47H 48H 49H 4AH Character used A B C D E F G H I J ASCII code 4BH 4CH 4DH 4EH 4FH 50H 51H 52H 53H 54H Character used K L M N O P Q R S T ASCII code 55H 56H 57H 58H 59H 5AH Character used U V W X Y Z HEF002
58H 59H 5AH Character used U V W X Y Z INR-244-831 3-9 Troubleshooting 4 Troubleshooting The table below shows the solutions for the problems.
Double piston construction achieves compact design with strong gripping force. q r Mounting is possible from 4 directions. e w Model Bore size Gripping force (N) q w MHF2-8D MHZ2-10D 8 10 19 11 MHF2-12D MHZ2-20D 12 20 48 42 w e r MHF2-16D MHZ2-25D 16 25 90 65 MHF2-20D MHZ2-32D 20 32 141 158 12-3-3 4 Series MHF2 Model Selection Model Selection Selection Procedure Confirm gripping force Confirm
Double piston construction achieves compact design with strong gripping force. q r Mounting is possible from 4 directions. e w Model Bore size Gripping force (N) q w MHF2-8D MHZ2-10D 8 10 19 11 MHF2-12D MHZ2-20D 12 20 48 42 w e r MHF2-16D MHZ2-25D 16 25 90 65 MHF2-20D MHZ2-32D 20 32 141 158 12-3-3 4 Series MHF2 Model Selection Model Selection Selection Procedure Confirm gripping force Confirm
(With 0.5 W power-saving circuit) VDW40: 6.5 W (With 1 W power-saving circuit) Power consumption IP65 Note 6) Enclosure Note 1) The amount of leakage from the OUT port when the set pressure is applied to the IN port.
) Max. operating frequency (Hz) [at 0.25 MPa] 1,200 1,000 550 350 650 550 300 200 600 500 250 150 Flow rate 100 L/min type Note 1) 24 VDC, Duty ratio 1:1 80 W: Current needs to be limited by using an energy saving driver circuit. 40 W: Current needs to be limited by using an energy saving driver circuit. 10 W: Energizing time is one second at a maximum.
Hydraulic fluid 0 1 2 N W V Petroleum Water-glycol, Emulsion Phosphoric ester Note) N, W and V refer to the hydraulic fluid symbol indicated at the end of the element part number. Replacement Element Part No.
Characteristics -20 -04 -10 -06 -24 -28 -12 -16 -08 10 Pressure drop (kPa) -30 10 100 1000 1 Flow rate (L/min) Conditions Fluid: Turbine oil Class 2 VG56 Viscosity: 45 mm2/s Filter material: Micromesh Nominal filtration: 74 m to 149 m 498 Vertical Suction Filter FHIA Series How to Order FH I A N 04 M M R 074 Vertical suction filter Relief valve Hydraulic fluid R D N W V With relief valve
Bore Size: 25mm, Cylinder Port: TN (NPT), Arm Opening Angle: 105 (105°), S: S, Option: X2797 (Base Type, w/out Clamp Arm)
Bore Size: 25mm, Cylinder Port: G, Arm Opening Angle: 105 (105°), S: S, Option: X2797 (Base Type, w/out Clamp Arm)
Bore Size: 25mm, Cylinder Port: G, Arm Opening Angle: 90 (90°), S: S, Option: X2797 (Base Type, w/out Clamp Arm)