SMC Corporation of America
Elite Part Number Search
Search Results "S070C-RBG-32-X50"

74 9.3 17 32 74 CRBU2 1.5 MPa Allowable surge pressure CRB1 Within 1 Backlash (2) + 4 0 MSU Tolerance in rotating angle Note 1) Output under the operating pressure of 0.5 MPa.

6 27 71.5 60 42 22 21 150.5 8 M8 x 1.25 25 to 800 25 to 650 50 35 12 13 10 59 40 27 11 27 21 52 20 10 17 9 32 80.5 70 46 24 28.5 162.5 11 M8 x 1.25 25 to 800 25 to 650 60 35 15 18 10 67 40 26 27 23 64 20 13 17 9 32 98.5 85 48.5 24 28.5 174 11 M10 x 1.25 13.5 25 to 750 25 to 600 70 40 17 23 14 72 52 30 32 23 78 25 15 21 11 37 117.5 102 55 26.5 36 189 13 M12 x 1.75 16.5 25 to 750 25 to 600

UNF 0.625 0.75 1.12 0.38 0.88 0.34 0.62 0.81 0.12 1.00 1/8 1.00 0.093 0.22 1/4-28 10-32 UNF 1/4-20 0.250 106 (1 1/16") 10-32 UNF 0.750 0.75 1.47 0.62 1.22 0.47 0.81 0.24 1.12 1.25 1/8 1.25 0.093 0.25 3/16-24 10-32 UNF 1/4-20 0.312 150 (1 1/2") 1/4-20 NUC 1.00 1.25 1.93 0.88 1.57 0.38 1.12 1.56 0.25 1.75 1/4 1.75 0.125 0.38 7/16-20 1/4-20 NUC 5/16-18 0.437 Block Mounting Type (in) ZB2 ZB3

to 212 [0 to 100] Ambient temperature F [C] 32 to 140 [0 to 60] Parts in contact with uid Diaphragm PTFE Body PFA Construction Integral ttings/LQ3 w Component Parts e No.

Compact Guide Cylinder/With Air Cushion Series MGP Replacement Procedure is 12, 16, 20, 25, 32 40, 50, 63, 80, 100 P.333 Construction MGPM12 to 25 MGPM32 to 100 @6 @4 @4 @6 @7 @5 @5 @7 The numbers are the same as the "Construction" of the Best Pneumatics No.3 Series MGP. *BLUE links will lead to purchase pages. Replacement Parts: Seal Kit Kit no.

Bore size (mm) RSH-R20 RSH-R20 RSH-R32 20 32 RSH-R32 190

Hygienic Design Cylinder/ISO Standard Type Series HYC 32, 40, 50, 63 Replacement Procedure is P.297 Hygienic Design Cylinder/ISO Standard Type Construction Hygienic Design Cylinder/ISO Standard Type Series HYC 32, 40, 50, 63 Series HYC 32, 40, 50, 63 Replacement Procedure is Replacement Procedure is !6 !5 !8 !7 !9 @1 P.297 P.297 Construction Construction !6 !5 !8 !7 !9 @1 !6 !5 !8 !7 !

Hygienic Design Cylinder Series HYG Replacement Procedure is 20, 25, 32 40, 50, 63 P.301 Hygienic Design Cylinder Series HYG Construction Hygienic Design Cylinder Replacement Procedure is Series HYG 20, 25, 32 40, 50, 63 Actuators Modular F.R.L. Pressure Control Equipment Air Preparation Equipment Industrial Filters Replacement Procedure Actuators Modular F.R.L.

Plug: KPP Applicable fitting size d Weight g D Model L A L A 4 KPP-04 6 32 13.8 0.4 D d 6 KPP-06 8 35 15.7 0.7 8 KPP-08 10 39 17.3 1.1 Applicable fitting size d 10 KPP-10 12 43 19.2 1.7 12 KPP-12 14 45.5 20.7 2.5 The plug is commom for KPQ, KPG and KP series. 360 KP/KPQ/KPG Series Specific Product Precautions 1 Be sure to read this before handling the products.

-196H-V 06 to 08 AL-197H-V 10 to 12 FKM-70 or EPDM-70 AL-198H-V Phosphoric ester 16 AL-199H-V 20 to 24 AL-200H-V 28 to 32 AL-201H-V Note) The material of seals (AL-196H-V to AL-201H-V) is EPDM-70.

Temperature Data B: Ambient Temperature AMH Inlet air temperature (C) Inlet air temperature (C) Ambient temperature (C) Ambient temperature (C) Correction factor Correction factor Correction factor Correction factor IDFA3E to 11E IDFA15E1 to 75E IDFA3E to 37E 1.33 IDFA55E to 75E IDFA100F to 150F IDFA100F to 150F AME 20 25 30 35 40 5 to 25 30 35 40 45 50 5 to 30 35 40 45 50 55 60 2 to 25 30 32

AMD AMH Data A: Inlet Air Temperature Data B: Ambient Temperature Data C: Inlet Air Pressure AME Inlet air temperature Ambient temperature Inlet air pressure MPa psi Correction factor F C Correction factor AMF Correction factor IDFB3E to 37E IDFB55E, 75E 1.31 F C 77 90 95 100 104 25 32 35 37.8 40 75 100 110 120 125 150 175 200 232 0.53 0.70 0.76 0.83 0.86 1.03 1.21 1.38 1.60 1.24 0.95 ZFC

0.00 0.07 Max. 5.0 (127.0) Max. 5.6 (142.2) (When selecting AK1050 and the panel mounting option) 0 100 200 300 400 Flow rate (slpm, N2) AK1000 100 psig (0.69 MPa) 40 psig (0.28 MPa) Inlet pressure: 80 psig (0.55 MPa) 20 psig (0.14 MPa) 1.50 (38.1) 50 0.34 2.25 (57.2) 40 0.28 Delivery pressure (MPa) Delivery pressure (psig) 30 0.21 0.69 (17.5) 2.00 (50.8) 20 0.14 10 0.07 0.88 (22.4) 2 x 10-32

AS1200-M3 AS1400-M3 AS120-M5 AS220-01AS220-02 AS320-03 AS420-04 10-32UNF Port size M3 x 0.5 2.5, 4, 6 1.05 MPa 0.7 MPa 0.1 MPa M5 x 0.8 1/8 1/4 20, 25, 32, 40 3/8 1/2 6, 10, 15, 20, 25 80, 100 32, 40, 50, 63 Applicable cylinder bore size (mm) 1.5 MPa 1 MPa 0.1 MPa Proof pressure Max. operating pressure Body swivels 360 Swivel type allows free setting of piping.

One branch of manifold valves/input unit can be connected to 32 outputs/32 inputs. Up to 4 branches can be connected (total 128 outputs/128 inputs). No.

One branch of manifold valves/input unit can be connected to 32 outputs/32 inputs.

Standard strokes Model Bore size(mm) Standerd stroke(mm) 12,16 10,20,30,40,50,75,100,125,150,175,200,250 121320,25 20,30,40,50,75,100,125,150,175,200,250,300,350,400 MGPL -Z 32 to 100 25,50,75,100,125,150,175,200,250,300,350,400 5.

(DC1224V) 1. 1-1 CEU2 1 2 32 32 1 16 P1 P2 P3 . P16 s1 s1 s1 s1 s2 s2 s2 s2 ... ... ... ... s32 s32 s32 s32 0.5mm) 1 2 , 2. 30mm 30mm 3.

.**. 29 (2-3) LECPLECA .32 1 - (2-3-1) LECPA . 32 (2-3-2) LECPA . 32 (2-3-3) LECPA . 34 5.4 .36 5.4.1 .36 (1) .36 (2) .38 5.4.2 .40 (1) .40 (2) .41 6. .42 6.1 .42 (1) .42 (2) .44 (2-1) LECPLECA .44 (2-2) LECPLECA .45 (2-3) LECPA .46 6.2 .47 (1) .47 (2) .47 (3) .48 (4) .50 (5) .51 (6) .52 (7) .54 (8) .54 6.3 .56 (1) .56 (2) .56 (2-1) .56 (2-2) .56 (3) .57 (3-1) .57 (3-1-a) TB Ver1.**. 57 (

4 Pneumatic type (non-lube) Piston seal Rod seal NBR CQ2B12-PS 12 16 20 25 32 40 50 63 80 100 CQ2B12-PS CQ2B16-PS CQ2B20-PS CQ2B25-PS CQ2B32-PS CQ2B40-PS CQ2B50-PS CQ2B63-PS CQ2B80-PS CQ2B100-PS CQ2B16-PS Gasket CQ2B20-PS CQ2B25-PS CQ2B32-PS Set of left nos. !2, !3, !4.