Search Results "CDQ2B32-35+0DCZ-XC11"

4) ( C)Pump capacity Note 5) (50/60 Hz)(MPa)Rated flow Note 6) ( l/min)Main tank capacity Note 7) ( l )Sub-tank capacity Note 8) ( l )Port sizeWetted parts materialTemperature range ( C)Pressure range (MPa)Required flow Note 9) (50/60 Hz) (l /min)Power supplyBreaker capacity (A)Rated current (A)AlarmCommunicationsHRZ001-LWater-cooled refrigerationR404A (HFC)PID controlTemperature: 10 to 35

(kW)Temp. stability Note 4) ( C)Note 5)(MPa)Rated flow Note 6) (l/min)Main tank capacity Note 7) ( l )Sub-tank capacity Note 8) ( l )Port sizeWetted parts materialTemperature range ( C)Pressure range (MPa)Required flow Note 9) (50/60 Hz) (l /min)Power supplyBreaker capacity (A)Rated current (A)AlarmCommunicationsHRZ001-L1Water-cooled refrigerationR404A (HFC)PID controlTemperature: 10 to 35

(kW)Temp. stability Note 4) ( C)Note 5)(MPa)Rated flow Note 6) (l/min)Main tank capacity Note 7) ( l )Sub-tank capacity Note 8) ( l )Port sizeWetted parts materialTemperature range ( C)Pressure range (MPa)Required flow Note 9) (50/60 Hz) (l /min)Power supplyBreaker capacity (A)Rated current (A)AlarmCommunicationsHRZ004-L1Water-cooled refrigerationR404A (HFC)PID controlTemperature: 10 to 35

Improved corrosion resistance with the use of stainless steel, plate type heat exchanger , Protects penumatic equipment from moisture , Rated inlet air temperature: 35 C , Refrigerant R134a(HFC), AIR DRYER, OTHERS, IDF REFRIGERATED DRYER, IDF OTHER SIZE(MISC./OTHER), 61.6 lb

MPa45 kPa or less at the maximum flow1 sVoltage output: 1 to 5 V Output impedance: 1 k7Output current: 4 to 20 mA Max. load impedance: 300 7 for 12 VDC, 600 7 for 24 VDCFor power supply status, flow rate indicator (Blinking speed changes in response to flow rate), and other error indicator12 to 24 VDC p10%30 mA or lessIP650 to 50oC (with no freezing and condensation)Operation, Storage: 35

Improved corrosion resistance with the use of stainless steel, plate type heat exchanger , Protects penumatic equipment from moisture , Rated inlet air temperature: 35 C , Refrigerant R134a(HFC), REFRIDG AIR DRYER, OTHERS, IDF REFRIGERATED DRYER, IDF OTHER SIZE(MISC./OTHER), 41.77759 lb

See individual series information for replacements. 5 port solenoid valve, metric - old style see replacement series SYJ5000 - New Style , Operating pressure range: 0.15 to 0.7 MPa , Response time (0.5MPa): 20 (2 pos. sgl/dbl) 35 (3 position) , Ambient and fluid temperature: Max. 50C , Lubrication: non-lube

10 to 60C (With no condensation and no freezing)Operating/Stored: 35 to 85%RH (With no condensation)10 to 500 Hz at whichever is smaller of 1.5 mm amplitude or 98 m/s2 acceleration, in X, Y, Z directions for 2 hrs. each (De-energized)980 m/s2 in X, Y, Z directions, 3 times each (De-energized)?3% F.S. or less1000 VAC for 1 min.

Improved corrosion resistance with the use of stainless steel, plate type heat exchanger , Protects penumatic equipment from moisture , Rated inlet air temperature: 35 C , Refrigerant R134a(HFC), REFRIGERATED AIR DRYER, OTHERS, IDF REFRIGERATED DRYER, IDF OTHER SIZE(MISC./OTHER), 118.8 lb

Improved corrosion resistance with the use of stainless steel, plate type heat exchanger , Protects penumatic equipment from moisture , Rated inlet air temperature: 35 C , Refrigerant R134a(HFC), REFRIGERATED AIR DRYER, OTHERS, IDF REFRIGERATED DRYER, IDF OTHER SIZE(MISC./OTHER), 158.73282 lb

fluidOperating temp. rangeCooling capacityHeating capacityTemperature stability Note 2)Pump capacityTank capacityPort sizeWetted parts materialTemperature rangePressure rangeRequired flow rate Note 3)Power supplyOvercurrent protectorCurrent consumptionAlarmCommunicationsHEC003-W5BThermoelectric device (Thermo-module)Water-cooledCooling/Heating automatic shift PID control50 to 95F (10 to 35C), 35

Operating temperature rangeCooling capacityHeating capacityTemperature stability Note 4)Pump capacityTank capacityPort sizeWetted parts materialTemperature rangePressure rangeRequired flow rate Note 5)Power supplyOvercurrent protectorCurrent consumptionAlarmCommunicationsHEC006-W2AThermoelectric device (Thermo-module)Water-cooledCooling/Heating automatic shift PID control50 to 95F (10 to 35C), 35

OUT1, OUT2: OrangeIP65Operating: 23 to 122F, Stored: 14 to 140F (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)1000 VAC for 1 minute between live parts and case50 M or more between live parts and case (at 500 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/

OUT1, OUT2: OrangeIP65Operating: 23 to 122F, Stored: 14 to 140F (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)1000 VAC for 1 minute between live parts and case50 M or more between live parts and case (at 500 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/

10 to 60C (No freezing or condensation)Operating and stored: 35 to 85% RH (No condensation)1000 VAC for 1 min. between live parts and enclosure50 M or more between live parts and enclosure (at 500 VDC Mega)10 to 150 Hz, at the smaller of amplitude 1.5 mm or 20 m/s2 in X, Y, Z directions for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions 3 times each (De-energized)?2% F.S.

10 to 60C (No freezing or condensation)Operating and stored: 35 to 85% RH (No condensation)1000 VAC for 1 min. between live parts and enclosure50 M or more between live parts and enclosure (at 500 VDC Mega)10 to 150 Hz, at the smaller of amplitude 1.5 mm or 20 m/s2 in X, Y, Z directions for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions 3 times each (De-energized)?2% F.S.

10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)1000 VAC for 1 minute between live parts and case50 M or more between live parts and case (at 500 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (Non-energized)100 m/s2 in X, Y, Z directions, 3 times each (Non-energized

OUT1, OUT2: OrangeIP65Operating: 23 to 122F, Stored: 14 to 140F (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)1000 VAC for 1 minute between live parts and case50 M or more between live parts and case (at 500 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/