with double knuckle joint. +0.058 0 +0.058 0 +0.070 0 +0.084 0 +0.084 0 0.10 0.30 0.10 0.30 0.10 0.30 0.10 0.30 0.10 0.30 14 19 24 26 26 20 22 28 40 40 30 40 50 60 60 M10 x 1.25 16 19 24 34 34 M10 x 1.25 10 11 14 20 20 16 19 24 34 34 40 50 64 80 80 10 10 14 22 22 14 14 20 30 30 28 28 40 60 60 10 10 14 22 22 14 14 20 30 30 12 M14 x 1.5 M14 x 1.5 12.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 M18 x 1.5
30 25 25 Cooling capacity [kW] Cooling capacity [kW] 20 20 15 15 10 10 5 5 0 0 5 10 15 20 25 30 35 5 10 15 20 25 30 35 Circulating fluid temperature [] Circulating fluid temperature [] 60Hz 50Hz Fig. 8-3: Cooling Capacity 8.5 Pump Capacity 0.6 60 Usable flow rate range 0.5 50 Circulating fluid outlet (60Hz) Lifting head [m] Pressure [MPa] 0.4 40 0.3 30 0.2 20 Circulating fluid outlet (50Hz
Wh'rl 1pc 4) 85 + 30{n 2 4l 10+30(2 2) 75+~24 80+30(11 2 With n pes , . f-f-("::--=-=2.c..; 4 ::-.6 8 '-c---4.,, 8 e.'-,-~.-,-,-'~')c-t-_-"_ _ c..;.-= 8. 12. ' 6 .. )_+_"",":.:=:.: 4 ,,-.",8." "L __--+_-" "'.-= .. ,L)_+--, (" =-,12 '6 (" =4 ',,,2'-.. , ,,,6 ::" ) _~ Wlth2pcs (DiHe!'
L1 E1 R1 U1 A1 U1 R1 A MM NDH10 NZ MM NDH10 NX NX E1 L1 30 40 50 60 60 20 22 28 40 40 12 12.5 16.5 23.5 23.5 16 19 24 34 34 32 40 50, 63 80 100 32 40 50, 63 80 100 14 19 24 26 26 10 11 14 20 20 16 19 24 34 34 40 50 64 80 80 M10x1.25 M14 x 1.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 M10 x 1.25 M14 x 1.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 10 10 14 22 22 14 14 20 30 30 28 28 40 60 60 10 10 14 22 22 14 14 20
thread length FL AL NA K A U F N N ZZ + Stroke Z + Stroke S + Stroke L H RR (mm) A AL F FL G H H1 I K D B1 CX L KA CD E MM N Bore (mm) 0 -0.033 0 -0.033 0 -0.033 0 -0.039 20 M8 x 1.25 20 18 15.5 13 8 13 10 9 10.5 10 20 41 5 33.5 5 30 6 25 M10 x 1.25 26 22 19.5 13 10 17 10 9 10.5 10 20 45 6 37.5 5.5 30 8 32 M10 x 1.25 26 22 19.5 13 12 17 10 9 10.5 11 22 45 6 46.5 5.5 30 10 40 M14 x 1.5 32
thread length FL AL NA K A U F N N ZZ + Stroke Z + Stroke S + Stroke L H RR (mm) A AL F FL G H H1 I K D B1 CX L KA CD E MM N Bore (mm) 0 -0.033 0 -0.033 0 -0.033 0 -0.039 20 M8 x 1.25 20 18 15.5 13 8 13 10 9 10.5 10 20 41 5 33.5 5 30 6 25 M10 x 1.25 26 22 19.5 13 10 17 10 9 10.5 10 20 45 6 37.5 5.5 30 8 32 M10 x 1.25 26 22 19.5 13 12 17 10 9 10.5 11 22 45 6 46.5 5.5 30 10 40 M14 x 1.5 32
30 st or less Over 30 st A A Symbol Symbol DB DB Stroke Stroke Bore size (mm) 12 16 20 25 Bore size (mm) 12 16 20 25 50 st or less Over 50 Over 50 50 st or less 30 st or less Over 30 st 43 39 4 6 8 16 0 55 49 43 6 8 10 22 0 65 57 10 61.5 10 12 27 14.5 0 74 47 63.5 16 62 13 16 32 14.5 0 79.5 47.5 8-20-9 10 Series MGQ Bore Size 32 to 100: MGQM, MGQL 4-YY depth YL W + Stroke 4-NN through 4-MM
0.7 70 0.6 60 Circulating fluid pressure[MPa] 0.5 50 Pump head[m] Availavel area 0.4 40 Outlet60Hz 0.3 30 Outlet50Hz 0.2 20 0.1 10 Return port Availavel area 0.0 0 10 20 30 40 Circulating fluid flow[L/min] Fig. 9-7 Pump capacity(HRS060--20-(BJM)) 9.7 Required facility water flow (For water-cooled type) 30 Facility water flow rate[L/min] 25 20 15 10 5 0 0 10 20 30 40 50 Facility water inlet
L dimension 310.5 23 298 22 335.5 25 323 24 360.5 27 348 26 385.5 29 373 28 410.5 31 398 30 435.5 33 423 32 460.5 35 448 34 485.5 37 473 36 39 498 38 40 510.5 Blanking plug KQP-23-X19 KQP-04-X19 KQP-06-X19 KQP-08-X19 KQP-10-X19 L A Dimensions Applicable fittings size d Model A L D D KQP-23-X19 KQP-04-X19 KQP-06-X19 KQP-08-X19 KQP-10-X19 3.2 6 8 10 12 31.5 32 35 39 43 3.2 4 6 8 10 16 16 18
Load Weight Allowable Moment MY3A, MY3B/M1 MY3A, MY3B/m1 MY3A, MY3B/M2 MY3A, MY3B/M3 30 20 50 40 30 200 100 50 100 20 40 30 10 MY3A 3B63 MY3A 3B63 50 40 30 10 20 5 4 3 2 MY3A 3B63 10 5 4 3 MY3A 3B63 20 MY3A 3B40 MY3A 3B40 MY3A 3B40 Load weight kg 5 4 3 Moment Nm Moment Nm Moment Nm 1 2 10 MY3A 3B40 0.5 0.4 0.3 0.2 1 2 MY3A 3B25 MY3A 3B25 5 4 3 MY3A 3B25 MY3A 3B25 0.5 0.4 0.3 1
2 20 20 10 10 10 5 4 3 4 5 3 4 5 3 2 2 2 1 1 1 1 5 10 20 10 5 1 20 30 10 5 1 20 30 Transfer speed (m/min) Transfer speed (m/min) Transfer speed (m/min) Lever-type weight of transferred object and transfer speed graphs (graphs (2) and (3)) show the values at room temperature (20 to 25C).
0 10 20 30 40 50 60 70 HECR010-A Circulating fluid: Ethylene glycol 20% Circulating fluid: Tap water 2500 2500 Ambient temperature 35C 2000 2000 Heating capacity [W] Heating capacity [W] 1500 1500 Ambient temperature 25C Ambient temperature 25C Ambient temperature 15C 1000 1000 500 500 0 0 Circulating fluid temperature [C] 0 10 20 30 40 50 60 70 Circulating fluid temperature [C] 0 10 20 30
30% 70% 300 50% Stroke mm AS2201F -02-10 200 100 50% 30% 10% 70% 0 400 MB 63 300 Stroke mm AS3201F -03-10 200 100 0 ANA1 -C12 T1075 400 MB 80 300 Stroke mm AS4000-03 200 100 0 400 MB 100 300 Stroke mm 200 AS4000-04 100 0 Solenoid valve Silencer Tubing Speed controller 200 300 400 500 600 700 800 900 1000 1100 1200 Speed at the end mm/s Applicable related components For details regarding
10 20 20 ZZ + 2 Stroke S + Stroke (mm) A AL Bore size Stroke range Standard Long B1 C D E F GA H H1 I J K KA MM NA P RA S 1 2 ZZ 20 20 20 13 14 14 20 20 2 2 2 2 2 2 3 3 12 14 18 25 30 32 40 50 8 10 12 16 20 20 25 30 14 16.5 20 26 32 38 50 60 13 17 17 19 27 27 32 41 0 0 0 10 10 10 10 10 26 31 38 47 58 72 89 110 15.5 19.5 19.5 27 32 32 37 37 93 93 95 87 102 102 122 122 5 6 6 8 11 11 13 16
unit Rotary actuator with angle adjustment Part number for CRBW---BPart number for vertical auto switch unit angle adjustment unit Part number for joint unit Size For D-M9 Excluding Size Size D-M9 10 P811010-3 10 P211070-10 10 P611070-1M P611070-1 15 P811020-3 15 P211090-10 15 P611090-1M P611090-1 20 P811030-3 20 P211060-10 20 P611060-1M P611060-1 30 P811040-3 30 P211080-10 30 P611080-1M
fluid outlet Lifting head [m] Pressure [MPa] 0.4 40 0.3 30 Usable flow rate range 0.2 20 Circulating fluid return 0.1 10 0 0 0 10 20 30 40 50 60 70 80 90 100 110 120 Circulating fluid flow [L/min] Fig. 8-9 Pump capacity(HRL100-A-20 CH1) 8.5.2 HRL200A20 CH1 0.6 60 0.5 50 Circulating fluid outlet Lifting head [m] Pressure [MPa] 0.4 40 0.3 30 Usable flow rate range 0.2 20 Circulating fluid
36 98 30 24 ANA1-06 3/4 90 110 111 46 36 ANA1-10 1 160 180 132 50 41 ANA1-12 11/4 280 544 200 74 60 ANA1-14 11/2 450 612 230 74 60 ANA1-20 2 610 873 271 86 70 ANB1-01 1/8 15 10 51 22 ANB1-02 1/4 35 22 81 25 18 ANB1-03 3/8 60 35 93 30 21 ANB1-04 1/2 90 94 107 46 24 ANB1-06 3/4 160 175 133 50 41 ANB1-10 1 280 462 190 74 41 ANB1-12 11/4 450 612 230 74 60 ANB1-14 11/2 610 871 271 86 70 D I M
Standard Strokes Bore size (mm) Standard strokes (mm) 20 32 40 50 63 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 Hydraulic Fluid Compatibility 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 80 100 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 Hydraulic fluid Compatibility
M2 M3 m2 m3 16 20 25 32 40 50 63 16 20 25 32 40 50 63 6.0 3.0 1.0 18 7 2.1 10 5.2 1.7 26 10.4 3 15 9.0 2.4 38 15 4.5 MY1MW 30 15 5.0 57 23 6.6 59 24 8.0 84 33 10 115 38 15 120 48 14 140 60 19 180 72 21 6.0 3.0 2.0 18 7 2.1 10 5.0 3.0 25 10 3 15 8.5 5.0 35 14 4.2 30 14 10 49 21 6 MY1CW MY1B 60 23 20 68 30 8.2 115 35 35 93 42 11.5 MY1H 150 50 50 130 60 16 The above values are the maximum allowable
Specifications LAT3-10 Stroke 10 mm, Resolution 30 m LAT3-20 Stroke 20 mm, Resolution 30 m Card Motor 8 options LAT3-30 Stroke 30 mm, Resolution 30 m (Refer to the table Product LAT3M-50 Stroke 50 mm, Resolution 5 m Number on the right) LAT3F-10 Stroke 10 mm, Resolution 1.25 m LAT3F-20 Stroke 20 mm, Resolution 1.25 m LAT3F-30 Stroke 30 mm, Resolution 1.25 m LAT3F-50 Stroke 50 mm, Resolution