) AC200V () [30mA 10A] 1.25mm 2 (16AWG) 812mm3 () 0.1m 30m (11 ) M3 6.5mm 2 5 2
power supply (+) Lock release (+) [I/O cable] LEC CK4 Cable length (L) [m] 1 3 5 1.5 3 5 Controller side PLC side (16) (10) (11) (30) (60) (L) Conductor size: AWG26 Dot mark Insulation color Terminal no.
I.D. 3 x Applicable tubing 1/8" (3.18) 0.086" (2.18) KFG2T0122-00 11 1.1 7 8 13.3 5 1.5 d H2 H2 H2 H1 0.098" (2.5) 5/32" (4) KFG2T0325-00 11 1.6 7 8 13.3 5 1.8 M 1/4" (6.35) 5/32" (3.95) d KFG2T0704-00 26 6 10 12 16.5 6 3.3 L 5/16" (8) 0.236" (6) KFG2T0906-00 39 17 12 14 18.7 6.6 5.3 M L M L 3/8" (9.53) 1/4" (6.35) KFG2T1163-00 70 19 15 17 22.2 7.6 5.6 1/2" (12.7) 3/8" (9.53) KFG2T1395-00
* ( ): Fluid: CO2 0.2 to 10 (5) l/min 1 to 50 (25) l/min 2 to 100 (50) l/min Panel mount adapter (For without flow adjustment valve) Port size ZS-33-J Symbol Description Flow rate range 10 Panel mount adapter A 50 11 C6 C8 6 One-touch fitting 8 (5/16") One-touch fitting Panel mount adapter B T Output specification B E 2 PNP outputs 1 PNP output + Analog (1 to 5 V) Panel Mounting bracket
12 10,11 10,11,12 08,09 1000 10 15 8 500 06,07 10 6 500 4 5 2 0 0 5 10 0 5 10 0 Number of needle rotations Number of needle rotations 15-9-101 11 Construction ASD230F ASD330F/430F ASD530F/630F ASD530F-02 !
0 (15) 25 D-M9, D-M9V 15 (17) 0 0 40 50 (57) 32 47 (49) 10 (17) D-F9W, D-F9WV 15 (17) 0 0 40 50 (57) 32 47 (49) 10 (17) D-A9, D-A9V 0 (15) 0 0 50 50 (61) 38 38 (53) 0 (11) 32 D-M9, D-M9V 10 (17) 0 0 50 55 (63) 38 48 (55) 5 (13) D-F9W, D-F9WV 10 (17) 0 0 50 55 (63) 38 48 (55) 5 (13) D-A9, D-A9V 0 (15) 0 0 54 54 (64) 48 48 (63) 0 (10) 40 D-M9, D-M9V 10 (17) 0 0 54 59 (66) 48 58 (65) 5 (12)
11-2 to 5-11-6. 0.6 1 (P) 3 (R) 1 (P) 3 (R) Pilot pressure (MPa) Pilot pressure range 0.5 N.C.
4-3/8 4-1/2 4-3/4 4-3/4 4-7/8 5 150 5-3/8 5-3/8 5-3/8 5-1/2 5-1/2 5-1/2 5-3/4 6 CAUTION: Horizontal or angle mounted cylinders (anything other than vertical) creates a bend stress on the rod when extended, just from the weight of the rod and cylinder itself.
4-3/8 4-1/2 4-3/4 4-3/4 4-7/8 5 150 5-3/8 5-3/8 5-3/8 5-1/2 5-1/2 5-1/2 5-3/4 6 CAUTION: Horizontal or angle mounted cylinders (anything other than vertical) creates a bend stress on the rod when extended, just from the weight of the rod and cylinder itself.
Weight 30 g (ZL3-) JSY3140 5 5-port solenoid valve JSY3000 series Specific Product Precautions Z Multistage ejector ZL 3 6 series Exhaust noise (Reference values) Z ZL3 6 5 Manual override Model ZL3 ZL6 Exhaust noise [dB(A)] 68 Electrical entry Refer to page 26.
LC6D Connector Cable LC6C Power Connector Cable Model LC6-1-C1--X258 Model LC6-1-C2--X252 Electric actuator LC6D Electric actuator LC6C Cable length 1 1m 3 3m 5 5m Cable length 1 1m 2 2m 5 5m Power connector Cable length: 1 to 5m Motor cable b Cable length: 1 to 5m 13 12 11 10 6 5 4 3 2 1 a Motor cable 7 13 12 11 10 9 8 6 5 4 3 2 1 Switch cable 14 15 16 17 18 Interface cable 7 9 8 Power cable
For pipe fitting 4B through 6B Applicable fittings For pipe fitting 3/4B through 3B Welding Welding Piping B Reducing tees B 1 1 x 1 x 1 24 or more 11/4 11/2 11/4 x 11/4 x 1 1B socket 11/2 x 11/2 x 1 cut in half 2 x 2 x 1 2 21/2 x 21/2 x 1 21/2 3 x 3 x 1 3 Pipe 4B through 6B Reducing tees B Socket Pipe : JIS B 2301 : JIS B 2302 : JIS B 3452 Without flash 16-12-8 4 Paddle Style Flow Switch
Note) Metric size Inch size Control type KE 0 1 Meter-out Meter-in 3.2 01 03 05 07 09 11 23 04 06 08 10 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 4 AS-FG 6 8 AS-FP With One-touch fitting 10 AS-FM AS-FM For low speed control Note) For applicable tubing O.D. selection, refer to the Model on page 716. Use 1/8" tube.
-1/8 (OUT port) 11 P = 22 11 1.5 4.5 6 32 6 54 ( 19.5) 11 9.5 11 9.5 4-M4 x 0.7 10 24 10 46 When not equipped with bracket, the M3 threads at both ends (4 positions) can be used for other purposes.
8 30 5 M8 x 1.25 13 26 15.5 23 f8 25 to 800 22 44 17 32 12 16 7 9 53 27 70 12 8 46 6 8 32 5.5 M10 x 1.25 13 28 19.5 25 f8 32 to 800 24 50 22 38 16 19 7 9 55 33 72 12 8 53 8 9 40 7.5 M14 x 1.5 13 36 21 31 f8 40 to 800 24 60 24 41 18 21 9 9 66 36 84 14 11 54 10 11 48 7.5 M16 x 1.5 19 44 21 34 f8 (mm) Bore size (mm) P NB NC NN S ZZ 20 19 15 M22 x 1.5 1/8 81 138 25 19 15 M24 x 1.5 1/8 81 143
PAX PB Tubing size Symbol 03 04 03 04 05 06 07 06 08 10 07 11 10 12 11 13 12 13 19 Body class Tubing O.D. 1/8", 3 4 1/8" 4 3/16" 6 1/4" 6 8 10 1/4" 3/8" 10 12 3/8" 1/2" 12 1/2" 3/4", 19 Body class 1 Symbol 1 2 3 4 5 Body class 1 2 3 4 5 Type of part Symbol U B N Type of part Nut & Insert bushing Insert bushing Nut 2 3 4 5 17-5-53 12 Series LVD Special Tools How to order fitting jigs LQ G
Single acting nomally open: External holding force, Single acting nomally closed: Internal holding force Refer to "Effective Holding Force" for the holding force at each holding position on p.2.4-7 to 2.4-11. Order Made P.2.4-17 2.4-5 Series MHK2 Construction Double acting Single acting @0 !8 !7 e w o Fingers open Normally open !9 t y !5 i u !6 q r !0 !1 !
mA), Holding 0.5 VA (5 mA) 100 VAC Inrush 0.55 VA (5 mA), Holding 0.55 VA (5 mA) 110 VAC Inrush 1.0 VA (5 mA), Holding 1.0 VA (5 mA) 200 VAC Inrush 1.1 VA (5 mA), Holding 1.1 VA (5 mA) 220 VAC Note 1) Use dry air to prevent condensation when operating at low temperatures.
NBR Silicon rubber NBR Silicon rubber NBR Silicon rubber NBR Silicon rubber NBR Silicon rubber NBR Silicon rubber ZP02 ZP04 ZP06 ZP08 ZP10 ZP13 ZP16 ZP20 ZP25 ZP32 ZP40 ZP50 ZP63 ZP80 ZP100 ZP125 5 7 8 2 2 4 4 7 9 11 2 4 5 7 10 4 6 8 10 5 5 10 10 7 9 9 10 13 10 8 13 11 13 11 10 11 16 20 25 32 12 14 9 9 13 15 19 25 33 13 15 20 26 35 14 17 20 24 30 15 18 21 26 33 14 14 13 20 18 12 13 11 17
SYJ300 Base Mounted (With Sub-plate) [ ] for AC Grommet (G), (H): SYJ34G H -M5 M5 x 0.8 (A port) 14 5 10 2-3.2 (For mounting) 26.4 17 3 2.5 Manual override A 11 G: Approx. 300 H: Approx. 600 (Lead wire length) 48.6 [50.8] (Light/surge voltage suppressor) 41.5 [48.5] + M5 x 0.8 (X port) 35.6 28.5 26.1 X R P 13 5 5 10 M5 x 0.8 (P, R port) 10 8.6 7.5 17.5 23 L plug connector (L): SYJ34-L-M5