Bore Size: 25mm, Stroke: 75mm, Adjuster: -, Function: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Bore Size: 25mm, Stroke: 75mm, Adjuster: Adjusters Both Ends, Function: Standard, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m [Or None in the Case of No Switch], Number: 1 pc.

Overcurrent protector 10 A 14 A Current consumption 5 A (100 V) to 2.5 A (240 V) 9 A (100 V) to 4 A (240 V) 10 A (100 V) to 4 A (240 V) 8 A (200 V) Power consumption 440 W*1 850 W*1 900 W*2 1500 W*2 Alarm Refer to Alarm.

Solid state auto switch: D-M9m 40 60 80 100 Long: MHL2-mD2 60 80 100 120 M Performance and mounting dimensions are interchangeable with the current model.

11 13 13 25 30 30 32 40 40 36 46 46 12 15 15 7 9 9 6.5 8.5 8.5 57 (65) 66 (74) 71 (79) 19.5 22.5 25 40 43 46 46 50 53 73.5 82 87 The figures in parentheses are the normally open type. 24 25 Series VX Safety Instructions The following safety instructions are intended to prevent a hazardous situation and/or equipment damage.

length) T (Arm thickness) Applicable hole diameter 12.5 12.7 14.5 14.7 15.5 15.7 17.5 17.7 19.5 19.7 24.5 24.7 4.5 13 6 9 31 224 29 222 4.6 5.5 15 7 31 11 224 29 222 5.6 6 16 7 11 31 224 29 222 6.1 7 18 8 36 12 229 34 227 7.1 8.5 20 8 36 13 229 34 227 8.6 10.5 25 8 36 15.5 229 34 227 10.6 P (Port thread size) P1 (Lock release port thread size) Nil G1/4 TN TF Nil TF TN Rc1/4 NPT1/4 Rc1/8

PS 24 27 GR-S-010(10g 14 30 1216 30 1216 30 2025 100 3263 100 15 17-2.

It can be used in the vacuum (up to 100 kPa) or low pressure line with 0.15 MPa or less.

IN side, OUT side 4 10 22 20 22 30 30 50 30 75 39 75 39 Series ZFB Model ZFB100-04 ZFB100-06 ZFB200-06 ZFB200-08 ZFB300-08 ZFB300-10 6 6 8 8 10 Metric size 3/16" 20 22 20 22 30 30 75 40 100 62 ZFB101-05 ZFB101-07 ZFB201-07 ZFB301-11 ZFB401-13 1/4" 1/4" Inch size (2) 3/8" 1/2" Specifications Fluid Air/Nitrogen Negative pressure 0.5MPa 0 to 60C (Non-freezing) 30m 0.15MPa Nylon/Soft Nylon/Polyurethane

SS5Y3-60Stations B (Light/surge voltage suppressor) Manual override (non-locking) Stations 2 3 4 5 6 7 8 9 10 (Station n) (Station 1) 43.3 (3.2) L1 110.5 123 135.5 148 160.5 173 173 185.5 198 33.4 (3) L2 100 112.5 125 137.5 150 162.5 162.5 175 187.5 L3 86 96.5 107 117.5 128 138.5 149 159.5 170 [44.7] L4 12 13 14 15 16 17 12 13 14 38.2 28.2 25.8 20.7 19.2 11 12 13 14 15 16 17 18 19 20 Stations

XT53440 05 Number of stations 05 06 12 1 station 2 station 8 station 13-9-10

sum CR (H) (L) Thermo-con STX COM Data ETX Check sum CR 101 100 10-1 10-2 (H) (L) Host ACK CR (Possible to omit) Host SOH UT ENQ COM Check sum CR (H) (L) Thermo-con SOH UT STX COM Data ETX Check sum CR 101 100 10-1 10-2 (H) (L) Host ACK CR (Possible to omit) COM indicates communication command.

44 37 13 16 45 18.5 M8 x 1.25 60 4.5 14 7 34 5.5 20 to 100 51 44 13 16 52 20 M8 x 1.25 69 5 14 7 40 5.5 30 to 100 57.5 49.5 15 20 64 28.5 M10 x 1.5 86 7 17 8 50 6.6 mm OB P Q RB S U Z Bore size (mm) 32 40 50 9 Rc 1/8 23 7 58.5 31.5 14 9 Rc 1/8 28 7 66 35 14 11 Rc 1/4 31.5 8 80 41 19 Refer to page 9 for details on rod end nut and accessories.

30 -100 -80 25 [L/min (AMR) ] -80 [L/min (AMR) ] [kPa] [kPa] 20 -60 -60 15 -40 -40 10 -20 -20 5 0 0 0 0.2 0.3 0.4 0.5 0 1 2 3 4 5 6 [MPa] [L/min (AMR) ] ZQ07A 0.43MPa -100 40 -100 35 -80 [L/min (AMR) ] -80 [L/min (AMR) ] 30 [kPa] [kPa] -60 25 -60 20 -40 -40 15 10 -20 -20 5 0 0 0 0 2 4 6 8 10 12 0.2 0.3 0.4 0.5 [MPa] [L/min (AMR) ] ZQ10A 0.43MPa -100 70 -100 60 -80 [L/min (AMR)

Figure 13-6 PLC Ethernet MPC Tags will show up in the Controller Tags under the name you gave the MPC 13.2.6. above Figure 13-7 PLC Input and Output Data for the Ethernet MPC 26 - IN20267 Setpoint 14.

Table 8-1 Quality standard for fresh water (tap water) Item Product Standard value For circulating fluid For facility water pH (at 25oC) 6.0 to 8.0 6.5 to 8.2 Electric conductance (at 25oC) [S/cm] 100 to 300 100 to 800 Chloride ion [mg/L] 50 or less 200 or less Standard Sulfuric acid ion [mg/L] 50 or less 200 or less item Acid consumption (at pH 4.8) [mg/L] 50 or less 100 or less Total hardness

Table 8-1 Quality standard for fresh water (tap water) Item Product Standard value For circulating fluid For facility water pH (at 25oC) 6.0 to 8.0 6.5 to 8.2 Electric conductance (at 25oC) [S/cm] 100 to 300 100 to 800 Chloride ion [mg/L] 50 or less 200 or less Standard Sulfuric acid ion [mg/L] 50 or less 200 or less item Acid consumption (at pH 4.8) [mg/L] 50 or less 100 or less Total hardness

Inch Size [mm] Model d T (R, NPT) H D1 D3 L1 L2 L3 L4 Note 1) A Note 2) M W1 W2 X Y Weight [g] Unlocked Locked Unlocked Locked AS221FS-01-01 (S) 1/8" 7.2 12 19.1 26.2 19.1 43.9 42.4 40.8 39.3 13.3 20 21.5 6.5 15 13 (13) AS221FS-01-03 (S) 5/32" 8.2 AS221FS-01-07 (S) 1/4" 11.2 20.8 27.9 14 (13) AS221FS-01-09 (S) 5/16" 13.2 22.4 29.5 14.2 15 (14) AS221FS-02-01 (S) 1/8" 1/8 13 (12.7) 7.2 20.9

0.15 mm 0.3 mm 0.03 mm 0.30 0.03 0.15 0.20 0.02 0.10 0.01 mm 0.10 0.01 0.05 0.05 mm 0.02 mm 0 0 0 Supply pressure [kPa] 75 100 125 150 175 200 225 Supply pressure [kPa] 75 100 125 150 175 200 225 Supply pressure [kPa] 75 100 125 150 175 200 225 Piping length: 5 m Piping length: 5 m Piping length: 5 m Reference pressure 0.06 Reference pressure 0.30 Reference pressure 0.60 The distance of

200 300 300 200 Usable range 100 100 Usable range 20 30 40 50 50 40 30 20 10 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 10 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Distance from cylinder shaft center: L0 (cm) Distance from cylinder shaft center: L0 (cm) Note: 1N = 0.2248lbf 1kg = 2.2046lb 1in = 25.4mm 1in = 2.54cm 100 80 REA63 REA50 50 40 30 REA40 REA32