Auto switch mounting brackets BQ2-012 are not used for sizes over 32 of DA9(V)/M9(V)/M9W(V)/M9A(V)L types. The above values indicate the operating range when mounted with the conventional auto switch installation groove. Individual -X 531 Series CXT Auto Switch Mounting Bracket: Part No.
D-A9(V)/M9(V)/M9W(V) Bore size (mm) Auto switch model 12 to 100 D-A9/A9V D-M9/M9V D-M9W/M9WV BMG2-012 BMG2-012 MGJ Other than the applicable auto switches listed in How to Order, the following auto switches can be mounted. For detailed specifications, refer to pages 1719 to 1827.
= 200 mm/s Supply pressure: P = 0.5 MPa Load mass: M = 0.2 kg (2N) Cylinder stroke: 300 mm Load mass: M = 10 kg Cylinder stroke: 400 mm Actuating orientation: Vertical transfer of work (Rod side flange) Maximum speed: v = 300 mm/s Supply pressure: P = 0.5 MPa REC25 provisionally selected from graph (1) (M = 10 kg, v = 300 mm/s) REC20 provisionally selected from graph (1) (M = 0.2 kg, v =
U Q R T (mm) (mm) Rod end male thread Applicable bore size V W X U R S T Q Part no.
= 200 mm/s Supply pressure: P = 0.5 MPa Load mass: M = 0.2 kg (2N) Cylinder stroke: 300 mm Load mass: M = 10 kg Cylinder stroke: 400 mm Actuating orientation: Vertical transfer of work (Rod side flange) Maximum speed: v = 300 mm/s Supply pressure: P = 0.5 MPa REC25 provisionally selected from graph (1) (M = 10 kg, v = 300 mm/s) REC20 provisionally selected from graph (1) (M = 0.2 kg, v =
= 200 mm/s Supply pressure: P = 0.5 MPa Load mass: M = 0.2 kg (2N) Cylinder stroke: 300 mm Load mass: M = 10 kg Cylinder stroke: 400 mm Actuating orientation: Vertical transfer of work (Rod side flange) Maximum speed: v = 300 mm/s Supply pressure: P = 0.5 MPa REC25 provisionally selected from graph (1) (M = 10 kg, v = 300 mm/s) REC20 provisionally selected from graph (1) (M = 0.2 kg, v =
Auto switch model Electrical entry Lead wire length (m) Indicator light Load voltage Special function Type Electrical entry Wiring (Output) Pre-wired connector 3 (L) 5 (Z) Applicable load 0.5 (Nil) 1 (M) AC DC Perpendicular In-line M9N M9P M9B M9NW M9PW M9BW F8N F8P F8B 3-wire (NPN) IC circuit 5 V, 12 V Solid state switch 3-wire (PNP) Relay, PLC 24 V Yes Grommet 2-wire 12 V 3-wire
, PLC Yes Grommet 24 V IC circuit Diagnostic indication (2-color display) 5 V, 12 V 12 V Solid state auto switches marked with are produced upon receipt of order.
state switch Relay, PLC 24 V 12 V Grommet Yes Water resistant (2-color indication) IC circuit 5 V, 12 V 12 V Auto switches marked with a symbol are produced upon receipt of order.
Lead wire length (m) Auto switch model Indicator light Electrical entry direction Load voltage Special function Electrical entry Wiring (Output) Applicable load Pre-wired connector 5 (Z) Type 0.5 (Nil) 1 (M) 3 (L) DC AC Perpendicular In-line M9N M9P M9B M9NW M9PW M9BW M9NV M9PV M9BV M9NWV M9PWV M9BWV 3-wire (NPN) IC circuit Solid state switch 5 V, 12 V 3-wire (PNP) 12 V 2-wire Relay, PLC
D-M9N-5 ( ) D-M9N-5 3 NPN IC PLC DC51224V(4.528V) 10mA DC28V 40mA 10mA 0.8V (40mA 2V ) DC24V 100A ON CE RoHS D-M9N-5 M2.54L 15 - 5. 5-1. 1. () 2. 3. 4. 1. 5-2. 1. 2. 3. 4. Nm JMHZ2-16D M3x0.5 0.59 16 - M6x23 6.3Nm M4x10 1.0Nm 17 - P165-2. M3x7 0.59Nm 18 - (0.7mm) 19 - 5-3.
.) < Applicable Auto switches > Solid state auto switch D-M9N(V)-900M9P(V)-900M9B(V)-900 D-M9NW(V)-900M9PW(V)-900M9BW(V)-900 Reed auto switch D-A90-900 Fig 4. How to Mount and Move the Auto Switch Fig 4.
The detectable piston speed V is expressed by the equation below.
D-M9(V) D-M9W(V) D-M9A(V)L Auto switch mounting bracket part no. 0.6 0.5 BMG2-012 0.9 0.5 Auto Switch Mounting Brackets: Precautions When auto switch is set on the mounting side as shown below, allow at least 2 mm run off space on mounting plate since the auto switch is protruded from the gripper edge.
Lead wire length (m) Auto switch model Electrical entry direction Load voltage Indicator light Electrical entry Wiring (Output) Special function 0.5 Nil 3 (L) Applicable load Type 5 (Z) AC DC 12 V A93 In-line Yes Grommet 2-wire Relay, PLC Reed auto switch 100 V 12 V 24 V M9N 3-wire (NPN) Yes Grommet Relay, PLC Solid state auto switch 24 V M9B 2-wire 12 V Lead wire length symbols 0.5
Lead wire length (m) Auto switch model Electrical entry direction Load voltage Indicator light Electrical entry Wiring (Output) Special function 0.5 Nil 3 (L) Applicable load Type 5 (Z) AC DC 12 V A93 In-line Yes Grommet 2-wire Relay, PLC Reed auto switch 100 V 12 V 24 V M9N 3-wire (NPN) Yes Grommet Relay, PLC Solid state auto switch 24 V M9B 2-wire 12 V Lead wire length symbols 0.5
Magnet: D (Built-in), Mounting: L (Axial Foot Style), Bore: 20mm, Port Thread: Rc, Stroke: 150mm, Cushion: A (Air Cushion), Rod End Thread: Rod End Thread, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal
Clean Series: 10 (Relief Type), Magnet: D (Built-in), Mounting: L (Axial Foot Style), Bore Size: 20mm, Port Thread: Rc, Stroke: 50mm, Cushion: Rubber Bumper, Rod End Thread: Male Rod End, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal
Clean Series: Relief Type, Magnet: Built-in, Mounting: Axial Foot Style, Bore Size: 20mm, Port Thread: Rc, Stroke: 50mm, Cushion: Rubber Bumper, Rod End Thread: Male Rod End, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: -, Number: -
Magnet: Built-in, Mounting: Axial Foot Style, Bore: 20mm, Port Thread: Rc, Stroke: 150mm, Cushion: Air Cushion, Rod End Thread: Rod End Thread, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: -, Number: -