Magnet: Built-in Magnet, Mounting: Basic, Tube Material: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 350mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M12-4 Pin Connector, Number: -, Made to Order: -
Magnet: Built-in Magnet, Mounting: Basic, Tube Material: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 100mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: Y7BA--Solid State, Water Resist., 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -, Made to Order: -
Magnet: Built-in Magnet, Mounting: Basic, Tube Material: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 250mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: Z73--Reed, DC Volt., AC Volt, 2 Wire, LED, Lead Wire or Prewired Connector: -, Number: -, Made to Order: -
Magnet: Built-in Magnet, Mounting: Basic, Tube Material: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 50mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: F5P--Solid State, Gen. Purpose, 3 Wire PNP, Lead Wire or Prewired Connector: 3m, Number: -, Made to Order: -
Magnet: Built-in Magnet, Mounting: Basic, Tube Material: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 50mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: G5P--Solid State, Gen. Purpose, 3 Wire PNP, Lead Wire or Prewired Connector: 3m, Number: -, Made to Order: -
Magnet: Built-in Magnet, Mounting: Basic, Tube Material: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 200mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewired Connector: 3m, Number: -, Made to Order: -
Magnet: Built-in Magnet, Mounting: Basic, Tube Material: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 300mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewired Connector: -, Number: -, Made to Order: -
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
l i O l e d o M s t e l t u o l i o f o r e b m u N k r a m e R 4 A V 4 s d n e h t o B 6 A V 6 s d n e h t o B Dimensions/Auto feed tank 0 1 A V 0 1 s d n e h t o B 6 1 A V 6 1 s d n e h t o B 4 B V 4 e d i s e n O 6 B V 6 e d i s e n O 8 B V 8 e d i s e n O s n o i t a c i f i c e p S h c t i w S t a o l F n o i t p i r c s e D 2 ~ 1 0 1 4 S I y t i c a p a C W 5 1 : C D , A V 5 1 : C A
They can be ordered in lots of 10 pieces. d D Series SY3000 SY5000 SY7000 Part No.
Rz 12.5 45 Female thread size Chamfered dimension D (Recommended value) M5 5.1 to 5.4 10-32UNF 5.0 to 5.3 2. Use G external threads with G internal threads. D For Uni Thread 45 Tightening method 1.
D-A9V 10 6 6 8.5 10 D-M9 D-F9W D-M9V D-F9WV 5.5 (4) 3 (2) 3 (3) 4 (3) 6 (4) Interference Note) Figures in parentheses are the case for D-M9, D-M9V switch types.
C D E F Dimensions Part no.
Series Variations Applicable auto switch models Standard variations Lock system Standard stroke (mm) Bore size (mm) Solid state switch Reed switch Type Model Action Series Built-in auto switch magnet With rod boot Spring lock Grommet Grommet Mounting 3 wire 3 wire 2 wire D-F59 D-F59W D-J59W D-F5P D-F5PW D-F5BAL (2 color indicator) (2 color indicator) 2 wire 4 wire 3 wire D-J59 D-F59F D-F5NTL
Analogue output D The setting time from when the flow applied to the flow switch reaches the set value, to when the ON-OFF output actually begins working. Delay time setting can prevent the output from chattering. Delay time Display range Displayable range of flow. Function to add digital filtering to the fluctuation of flow value.
Configuration One thermo-chiller for one controller. 2 2 R D R D 3 3 S D S D 5 5 S G S G Controller Master This product Do not connect any wire to other PIN numbers. Fig. 3-13 Connection of RS-232C 3.3.10 Ethernet Modbus/TCP Communication wiring This product can operate the following by Ethernet Modbus/TCP communication.
Dec Z yZ ZZ AZ BZ CZ DZ . 400 400 This manual provides the following symbols in addition to Danger, 300 300 This unit does not use parts that meet the SCCR specifications.