Magnet: D (Built-in Magnet), Mounting: T (Center Trunnion), Tube Material: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 250mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in Magnet), Mounting: T (Center Trunnion), Tube Material: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 350mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in Magnet), Mounting: T (Center Trunnion), Tube Material: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 100mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)
Magnet: D (Built-in Magnet), Mounting: T (Center Trunnion), Tube Material: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 100mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)
Magnet: D (Built-in Magnet), Mounting: T (Center Trunnion), Tube Material: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 150mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: M9PWV--Solid State, 2-color Indication, 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: SDPC (0.5m Cord Length, M12-4 Pin Connector)
Magnet: D (Built-in Magnet), Mounting: T (Center Trunnion), Tube Material: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 600mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal
Magnet: D (Built-in Magnet), Mounting: T (Center Trunnion), Tube Material: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 200mm, Bellows/Cushion: N (w/o Cushion), Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in Magnet), Mounting: T (Center Trunnion), Tube Material: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 300mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: M (1m)
Magnet: D (Built-in Magnet), Mounting: T (Center Trunnion), Tube Material: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 100mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal
Magnet: D (Built-in Magnet), Mounting: T (Center Trunnion), Tube Material: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 400mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in Magnet), Mounting: T (Center Trunnion), Tube Material: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 300mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in Magnet), Mounting: T (Center Trunnion), Tube Material: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 150mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Made to Order: XC35 (w/Coil Scrapper)
Magnet: D (Built-in Magnet), Mounting: T (Center Trunnion), Tube Material: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 100mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Made to Order: XC35 (w/Coil Scrapper)
4 Short head cap screw 63 Top cover kits CKZ2N-T063 80 CKZ2N-T080 Note 1) T = TURCK, P = P&F Note 2) Please specify the opening angle by the code in Table 1. 196 A Power Clamp Cylinder Series CKZT Allowable Locking Moment Bore size (mm) Allowable locking moment Nm lbfin 40 380 3363 50 800 7080 63 1500 13274 CK1 CLK2 C(L)KQ MK2T/MK2/MK CKZ2N CKZT CLKZ1R CK/M(D)UKA 80 2500 22124 The moment
for AC, since a rectifier prevents surge voltage generation. 1 100 VAC (50/60 Hz) 2 200 VAC (50/60 Hz) 3 110 VAC (50/60 Hz)[115 VAC (50/60 Hz)] 4 220 VAC (50/60 Hz)[230 VAC (50/60 Hz)] 5 24 VDC 6 12 VDC Electrical entry D DIN terminal (Type D) With connector DO Without connector * DC specification of type D and DO is only available with 12 and 24 VDC.
Mandrel Here, : Deformation ration (%) d: Tube diameter (mm) L: Measured length (mm) D: Mandrel diameter (mm) (Twice against the minimum bending radius) Handling of One-touch Fittings Test temperature: 20 5C Relative humidity: 65 5%. Caution 3. Applicable for general industry water. Please consult with SMC if using other fluids.
The drain pipe for the air filter in the D. P . Lube Unit must have a minimum pipe bore of 10, and a maximum length of 5 m. Avoid using a riser pipe because it could cause the auto-drain to malfunction. 2. If installing an air tank, install it on the IN side of the D.P . Lube Unit.
W: 800 [W] w Derive the heat generation amount from the power supply output.
VX2 VX Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Piping Caution VX3 When high temperature fluids are used, use fittings and tubing with heat resistant features. (Self-align fittings, Teflon tubing, Copper tubing, etc.)
1000 1200 1400 1600 1600 0 0 200 400 600 800 1000 1200 1400 Flow rate l/min (ANR) Flow rate l/min (ANR) ARBQ4000-00-P (PA) ARBQ4000-00-P (PB) 0.7 0.7 0.6 0.6 Downstream pressure MPa Downstream pressure MPa 0.5 0.5 0.4 0.4 0.3 0.3 0.2 0.2 0.1 0.1 0 0 200 400 600 800 1000 1200 1400 1400 0 0 200 400 600 800 1000 1200 Flow rate l/min (ANR) Flow rate l/min (ANR) 1MPa = 145 psi Nl/min X 0.035