SMC Corporation of America
Elite Part Number Search
Search Results "CDQ2D40-50DCMZ-A93"

DD1629 Reed Auto Switch Direct Mounting Style D-A90(V)/D-A93(V)/D-A96(V) Refer to SMC website for the details of the products conforming to the international standards.

Lead wire length symbols: 0.5 mNil (Example) A93 3 mL (Example) Y59BL 5 mZ (Example) F9NWZ There are other applicable auto switches than listed above. For details, refer to page 8-11-101.

Nil (Example) A93 3m . L (Example) A93L 5m .

Tie-rod mount Reed switches 2 color indication With timer 2 color indication 2 color indication/water resistant 2 color indication/with diagnostic output Direct mount D-A93 D-G39/K39 D-F5/J5 D-F5NTL D-F5W/J59W D-F5BAL D-F5F D-F9N Band mount Tie-rod mount Solid state switches D-F9P Direct mount D-F9B Models D-A90, D-A93, D-F9N, D-F9P and D-F9B are exclusively for use with the lock unit

Lead wire length (m) Indicator light Load voltage Applicable load Rail mounting Direct mounting Pre-wire connector Wiring (Output) Special function Type Electrical entry 32 to 100 12 to 100 0.5 (Nil) 3 (L) 5 (Z) None (N) AC DC In-line In-line Perpendicular Perpendicular 3-wire (NPN equivalent) IC circuit 5V A76H A96 A96V Grommet A72H A73H 200 V A72 A73 A73C A93 A93V Reed switch Solid

) A93 3mL A93L PLC: Programmable Logic Controller Refer to applicable auto switch list Page 182.

Weight/( ): Denotes the values with D-A93. (g) Bore size (mm) Hexagon socket head cap screw dia.

For D-A93, only outward electrical entry (D dimension) is available. Dimensions in parentheses apply to 12-CXSJ10.

Example) MY2H40G-599L-A93-XB10 2 Long Stroke -XB11 4 Copper-free Specifications 20Available with long strokes exceeding the standard strokes.

NPN) Piping IC 5V A76H A96V A96 200V A72H A72 Screw-in piping With One-touch fitting (2) F Yes Yes No No Yes Yes Grommet A73H A73 Reed switch 12V 100V A93V A93 Note 2) The tubes for the built-in One-touch fittings are 32 to 63. They cannot be used for the air-hydro.

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket: