For stopping accuracy, refer to Series CLJ (P. 9-2-12), Series CLM2 (P. 9-2-20), Series CLG1 (P . 9-2-30), and Series CL1 (P . 9-3-2) respectively. 7. In order to further improve stopping accuracy, the time from the stop signal to the operation of the lock should be shortened as much as possible.
20, 25, 32 For "Long Stroke", refer to P. 36.
Port size (P, A and B port) Rated voltage M5 M5 x 0.8 01 Rc 1 8 1 2 3 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 110 VAC, 50/60 Hz 220 VAC, 50/60 Hz R1, R2: M5 4 Option 5 6 24 VDC 12 VDC Nil None With bracket (Not assembled) 7 240 VAC, 50/60 Hz 9 Other Option F Option Part No. Description Part no.
Target position Rotation speed Dwell Auxiliary time constant time constant [10STMm] [r/min] [ms] function [ms] [ms] 1 5.00 3000 100 150 100 1 2 -6.00 2000 100 100 0 3 3 3.00 3000 50 50 0 0 (Note) Note.
If our calculated Cv for the system including valve and fittings is Cvsyst, then: required Cv for valve Cvsyst 2 for fittings and tube Cvsyst 2 If tube system has 3 meters of nylon pipe and 6 KQ fittings we can consider this as 9 (3 6) elements so Cv for each fitting element needs to be: Cvsyst 2 9 9 elements assumed all equal P (assumption 50% P valves 50% P tube etc) The SMC
(mm) Electrical entry P Port size B C D E F H K L M N A Model Grommet: G Conduit: C Conduit terminal: T Q R Q R Q R S U 13.5 28 64 31 6.5 12.5 28 14 12.8 M4 4.5 22 59 44 50 99 50 66 83 1/8 VCS21 18 36 67.5 31 8.5 12.5 28 18 12.8 M4 6 22 62 44 53 99 53 66 86 1/4 22 40 81.5 36.5 11 15 32 20 19 M5 8 24 76 46 66.5 101 66.5 68 99 1/4, 3/8 VCS31 30 50 86 36.5 13.5 15 32 25 23 M5 8 24 80 46 71 101
Accumulated pulse output P ON OFF Output mode OUT1 50 msec ON n OFF Note1) Note 1) Output mode is set to inverted output when shipped from factory.
Basic weight 0.74 P Additional weight 0.11/50 stroke P Cylinder stroke 100 stroke P Locking weight 0.08 (Locking at head end, manual release non-locking style) 0.74+0.11X100/50+0.08=1.04kg All mounting bracket 0.11 0.16 0.26 0.27 0.42 0.56 Additional weight per 50 stroke Single knuckle 0.15 0.23 0.26 0.26 0.60 0.83 Accessories Double knuckle (with pin) 0.22 0.37 0.43 0.43 0.87 1.27 1.7-
adapter Vertical VAC VAC ZP3-T VAC p. 138 p. 144 p. 150 p. 156 With adapter Lateral ZP3-Y Construction Precautions Mounting Bracket Assembly VAC VAC VAC p. 139 p. 145 p. 151 p. 157 With adapter VAC VAC VAC Vertical ZP3-T p. 140 p. 146 p. 152 p. 158 With buffer Lateral ZP3-Y p. 141 p. 147 p. 153 p. 159 With buffer VAC VAC VAC 134 Compact Type ZP3 Series Specifications Pad Material Material
0 e w t y q o 5 (EA) 1 (P) 3 (EB) 5 (EA) 1 (P) 3 (EB) 3 position pressure center 4(A) (A) 4 (B) 2 2(B) 5 (EA) 1 (P) 3 (EB) 5(EA) 1(P) 3(EB) i Component Parts 2 position single with back pressure check valve Material Note Description No. q w e r t y u i Zinc die-casted Body r u !
U P DOWN Press and SET : Accumulation starts and flashes.
8 50 36* 4.5* 40.1 69.8 61.4 M4 x 12 M5 x 25 10 LZ 32 LC3F2 NZ M5 x 0.8 9 70 50 5 47.5 89.8 66.9 M3 x 12 M5 x 40 14 NY M4 x 0.7 8 70 50 5 47.5 89.8 66.9 M3 x 12 M5 x 40 14 NX M5 x 0.8 9 63 50 5 51 89.8 66.9 M4 x 12 M5 x 40 9 NW M5 x 0.8 9 70 50 5 48.8 89.8 66.9 M4 x 12 M5 x 40 9 NV M4 x 0.7 8 63 50 5 51 89.8 66.9 M4 x 12 M5 x 40 9 NU M5 x 0.8 9 70 50 5 48.8 89.8 66.9 M4 x 12
No.RS2H-OM0045PC / RS2H (5080) P.2 1. P.4 1-1. 1-2. 1-3. 1-4. 2. P.5 3. P.8 3-1. 3-2. 3-3. 3-4. 3-5. 3-6. 3-7. 4. P.12 5. P.12 6. P.13 6-1. 6-2. 6-3. 6-3-1. 6-3-2. 6-3-3. 6-3-4. 6-4. 6-4-1. 6-4-2. 7. P.17 7-1. 7-2. 7-3. 7-3-1.D-M9/A9 7-3-2.D-P3DW 8. P.20 8-1. 8-2. 9. P.21 10.
VQ VKF Surge voltage suppressor mounting part (For G) VQZ VZ VS VFN Surge voltage suppressor Electrical entry G Grommet, 300 mm lead wire H Grommet, 600 mm lead wire C Conduit JIS Symbol T Conduit terminal D DIN terminal Rated voltage 50 60 1 2 3 100 VAC, Hz 200 VAC, Hz 110 VAC, Hz 220 VAC, Hz 50 60 50 60 4 50 60 5 6 24 VDC 12 VDC 7 240 VAC, Hz 50 60 9 Other Option Manifold Accessory
Contact P/A for more details.
l (mm) 10 400 Eccentric distance l (mm) MGTL100 300 200 300 MGTM100 200 P = 0.5 MPa 100 P = 0.5 MPa Load weight m(kg) Larger than 75st Load weight m(kg) 40 50 100 Larger than 50st 50st 25st 30 25, 50st 20 50 40 10 30 5 4 3 2 20 1 10 20 30 40 50 100 200 300 1 2 3 4 5 10 20 304050 100 200 300400 Eccentric distance l (mm) 10 400 Eccentric distance l (mm) Allowable side load F(N) 1 N: Approx
) Y7BA P.12 Lead wire length symbols: 0.5m .
Actuation Plug Plug (A) 4 (B) (2) Number of solenoids (A) (4) (B) 2 Single 5 (EA) 1 (P) 3 (EB) 5 (EA) 1 (P) 3 (EB) Plug Plug (A) (4) (B) 2 (A) 4 (B) (2) Manual Override Operation Double Warning 5 (EA) 1 (P) 3 (EB) 5 (EA) 1 (P) 3 (EB) Light/Surge Voltage Suppressor Handle carefully, as connected equipment can be actuated through manual override operation.