SMC Corporation of America
Elite Part Number Search
Search Results "CLSF250TN-1600-D"

Magnet: None, Mounting: Front Flange, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 250mm, Thread: NPT, Stroke: 1400mm, Option: -, Cylinder Switch Type: -, Lead Wire or Pre-wired Connector: -, Number: -, Lock Unit Built-in Magnet: -, Lock Unit Switch Type: -

Magnet: None, Mounting: Front Flange, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 250mm, Thread: NPT, Stroke: 1500mm, Option: -, Cylinder Switch Type: -, Lead Wire or Pre-wired Connector: -, Number: -, Lock Unit Built-in Magnet: -, Lock Unit Switch Type: -

Magnet: None, Mounting: Front Flange, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 250mm, Thread: NPT, Stroke: 1100mm, Option: -, Cylinder Switch Type: -, Lead Wire or Pre-wired Connector: -, Number: -, Lock Unit Built-in Magnet: -, Lock Unit Switch Type: -

Magnet: None, Mounting: Front Flange, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 250mm, Thread: NPT, Stroke: 100mm, Option: -, Cylinder Switch Type: -, Lead Wire or Pre-wired Connector: -, Number: -, Lock Unit Built-in Magnet: -, Lock Unit Switch Type: -

Magnet: None, Mounting: Front Flange, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 250mm, Thread: NPT, Stroke: 400mm, Option: w/o Cushion, Cylinder Switch Type: -, Lead Wire or Pre-wired Connector: -, Number: -, Lock Unit Built-in Magnet: -, Lock Unit Switch Type: -

Magnet: None, Mounting: Front Flange, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 250mm, Thread: NPT, Stroke: 1000mm, Option: -, Cylinder Switch Type: -, Lead Wire or Pre-wired Connector: -, Number: -, Lock Unit Built-in Magnet: -, Lock Unit Switch Type: -

Magnet: None, Mounting: Front Flange, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 250mm, Thread: NPT, Stroke: 300mm, Option: -, Cylinder Switch Type: -, Lead Wire or Pre-wired Connector: -, Number: -, Lock Unit Built-in Magnet: -, Lock Unit Switch Type: -

Magnet: None, Mounting: Front Flange, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 250mm, Thread: NPT, Stroke: 800mm, Option: -, Cylinder Switch Type: -, Lead Wire or Pre-wired Connector: -, Number: -, Lock Unit Built-in Magnet: -, Lock Unit Switch Type: -

Magnet: None, Mounting: Front Flange, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 250mm, Thread: NPT, Stroke: 2400mm, Option: -, Cylinder Switch Type: -, Lead Wire or Pre-wired Connector: -, Number: -, Lock Unit Built-in Magnet: -, Lock Unit Switch Type: -

Cylinder (Tube) Inner Diameter(φ): 250, Stroke(mm): 1025, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Cylinder (Tube) Inner Diameter(φ): 250, Stroke(mm): 190, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Cylinder (Tube) Inner Diameter(φ): 250, Stroke(mm): 500, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Cylinder (Tube) Inner Diameter(φ): 250, Stroke(mm): 600, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Nil P NPN PNP Bar length (mm) 340 400 460 580 640 820 1120 1300 1600 1900 2320 2500 With 2 pcs. 340 400 460 580 640 820 1120 1300 1600 1900 2320 2500 Since input/output function cannot be used, specify Nil when the AC adapter is being used.

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CLS1 ONE WAY LOCK-UP CYLINDER, YD, 250MM CLS1 DOUBLE ACTING, 718 lb

By separating the lock mechanism and the brake cylinder, SMC has minimized the influences of unlocking air quality such as moisture and condensation.Fail safe construction, Equal holding force in both directions, Lock unit switch, Improved maintainability, Strokes to 1600 depending upon mounting brackets, Auto switch capable cylinder, Auto switch capable brake unit, CLS Cylinder, CLS,

(Or None in the Case of No Switch), Lock Unit Built-in Magnet: D (Built-in), Lock Unit Switch Type: A90L--Reed, AC Volt, Horizontal, 3M

(Or None in the Case of No Switch), Lock Unit Built-in Magnet: D (Built-in), Lock Unit Switch Type: M9N--Solid State , Gen. Purpose, 3 Wire NPN, Horizontal, 0.5M

(Or None in the Case of No Switch), Lock Unit Built-in Magnet: D (Built-in), Lock Unit Switch Type: M9P--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, 0.5M

(Or None in the Case of No Switch), Lock Unit Built-in Magnet: D (Built-in), Lock Unit Switch Type: M9P--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, 0.5M