SMC Corporation of America
Elite Part Number Search
Search Results "FH342-06-100-M010X0"

Max Operating Pressure: 14 MPa, Construction: Element Upward Removal, Flange, Port Size: 08 [1 Threaded, 25 (1) Flange SSA], Pressure Indicator: Differential Pressure Indication Switch, Relief Valve: None, Fluid: Petroleum, Element: Micromesh, Filtration: 10μm, Fluid Direction: IN Left, Made to Order: Non-standard Filtration

FH series suction filters are compact and lightweight. Designed with an aluminum casted housing. Element can be replaced by simply opening the cover to detach the element without touching the pipes. The filter can be fitted with a differential pressure indicator which senses when the element is becoming dirty, facilitating maintenance and helping to avoid pump damage such as cavitations.

FH series suction filters are compact and lightweight. Designed with an aluminum casted housing. Element can be replaced by simply opening the cover to detach the element without touching the pipes. The filter can be fitted with a differential pressure indicator which senses when the element is becoming dirty, facilitating maintenance and helping to avoid pump damage such as cavitations.

FH series suction filters are compact and lightweight. Designed with an aluminum casted housing. Element can be replaced by simply opening the cover to detach the element without touching the pipes. The filter can be fitted with a differential pressure indicator which senses when the element is becoming dirty, facilitating maintenance and helping to avoid pump damage such as cavitations.

ASN AQ ASV AK How to Order VCHC F S 1 0 03 06 3 2 AS ASR ASQ Hexagon lock nut Round lock nut J Nil Lock nut option Speed controller Option None Electroless nickel plated Nil N Body size 1 2 3 4 M5 standard 01, 02 standard 03 standard 04 standard Tube size Note) With seal 04 06 08 10 12 4 6 8 10 12 Made to Order Refer to page 612 for details.

How to Order Symbol 2 1 01 06 2 AS 1 F E S K JIS Symbol Hexagonal lock nut Body size 2 3 4 1/8, 1/4 standard 3/8 standard 1/2 standard With seal Applicable tubing O.D.

VR VR51 VR51 Supply pressure and piping length at the outlet side VHK 50 Outlet piping length (m) VH 40 VHS 30 20 VHS 10 0 0 0.2 0.4 0.6 0.8 1 Supply pressure (MPa) When the piping length is long and capacity is large due to a branch, install a speed controller (AS2051F-06, AS3001F-06, etc.) close to the A port of the VR51 in accordance with the below figure.

---t~-+.,,-,H 06~L 0.5 ,~__:8Not suitable for a compressor with capacity less than 0.7Skw. (100 f! Imin (ANR)) ~ ," --f '" ~OA ~ OOperating pressure is 0.1 MPa{1.0kgf!cm2} or more. (Float type normally close) ~ 0. 3 ,,-O Can be used with a compressor with capacity lower than 0.7Skw Q. ~--~--~~. Qi . .3 0.2k .

Applicable cylinder bore size (mm) AS121-M5 Model Port size 4 6 8 10 12 M5 x 0.8 6, 10, 16, 20 Construction 1 8 AS221-01 R 20, 25, 32 1 4 AS221-02 R 20, 25, 32, 40 3 8 AS321-03 R 40, 50, 63 1 2 AS421-04 R 63, 80, 100 Note) marking is electroless nickel plated, provided as standard.

Part Number Description: T-TYPE BRACKET NAC4000-06 ONLY   Product Line: E   Product Line Description: AIRLINE EQUIPMENT   Family Code: 100   Family Description: AC FRL COMBO   Class Code: 22   Part Code: 2   Reference Code:  B   Click here to report information errorImage shown may not match exact part number, T-TYPE BRACKET NAC4000-06 ONLY, AIRLINE EQUIPMENT, AC FRL COMBO, 22, AC NO

How to Order Symbol 2 1 01 06 2 AS 1 F E S K JIS Symbol Hexagonal lock nut Body size 2 3 4 1/8, 1/4 standard 3/8 standard 1/2 standard With seal Applicable tubing O.D.

Etfective Orifice (mm2) NPTF (Base mount type) 1 1 3 02=1h 03 = 3/s I .t 1 30 Q2=1/t 03=9e O4=1/z 1 45 03 =3/8 04=1/z 06=aa (Base mount type) 1 2 02=lL 03 = 3/s 8 4.5 4 ?.

(g) 120 1 1 0 100 90 80 l|AN20002 U1 35 (1.9) .04 (17) NAN3OO-N03 % 60 (3.3) .06 t25) NANtrco+to4 90 (5.0) .08 (35) 60 NAN50(rN0,6 3A 160 (8.8) .36 (165) NAN6OO.NI O 1 27O llsl .46 e25) NAN700+i12 1]4 444 Q4l 1 .87 (4901 Supply pressure: 7l PSI Distance from silencer: NAN200-500-) 31t NAN6O0-7OO+ 6.5fi MN800_900 ,10f1 NANSOO-N,'4 1\h 590 (33) 2.21 (580) NANgOO-N2O 2 960 (53) 3.13 (820) Construction

N.O. 100 Electrical Terminology 1. Surge voltage A high voltage which is momentarily generated in the shut-off unit by shutting off the power. VCW 7 Cv=1.38 3 4 VCW 10 Cv=2.1 3 4 VCW4 5 Cv=0.85 VCW2 2 Cv=0.16 10 Flow rate Ql /min 5.0 Other 1. Materials NBR: Nitrile rubber FKM: Fluoro rubber Trade names: Viton, Dai-el, etc.

Part Number Description: L-TYPE BRACKET NAC4000-06 ONLY   Product Line: E   Product Line Description: AIRLINE EQUIPMENT   Family Code: 100   Family Description: AC FRL COMBO   Class Code: 22   Part Code: 2   Reference Code:  B   Click here to report information errorImage shown may not match exact part number, L-TYPE BRACKET NAC4000-06 ONLY, AIRLINE EQUIPMENT, AC FRL COMBO, 22, AC NO

AS Series How to Order 2 2 0 01 06 W2 AS 1F Body size 2 1 M5 standard 1/8, 1/4 standard 3/8 standard 1/2 standard 3 4 Metric size Applicable tubing O.D. Note) Elbow 06 08 10 12 6 8 10 12 Control type Meter-out Meter-in 0 1 Note) For applicable tubing O.D. selection, refer to the Model on page 603.

Made to Order How to Order 2 1 F 06 200 AS S Lubricant: Vaseline -X12 Example) AS2002FS-04-X12 Made to Order Body size Grease-free (Seal: Fluorine-coated) + Restrictor (Without check valve) -X21 100 M5 standard 200 1/8 standard 205 1/4 standard 300 3/8 standard 400 1/2 standard Applicable tubing O.D.1 Example) AS2002FS-04-X21 Not particle-free Metric size Inch size 23 3.22 04 4 06 6 08 8

Available in 1/8 ~ 1 Tube Diameters, For All Body Series Class 100 Cleaning & Packaging Series LVQ HowT o Order LVQ 2 0 S 07 Body Class Space Saving Option Symbol 2 3 4 5 6 Body Class 2 3 4 5 6 Orifice Dia. 4 8 10 16 22 S Space saving connection Pilot Connection Nil M N LQ LQ Thread type 1/8 diameter 5/32 (4mm) NPT1/8 Diff. Dia.