G5-S 50 stroke or less CV MVGQ CC RB J DKit no.
P o i n t Refrigeration circuit control system requires the minimum basic essential function. Temperature control system requires the minimum basic essential function. P o i n t According to the amount of heat generated from users equipment, the system turns power ON/ OFF to the compressor and controls the electronic valve.
VKF (A) 2 (A) 2 VQZ 1 (P) 3 (R) 1 (P) 3 (R) VZ VS VFN r e w q r e w q N.O. N.O. (A) 2 (A) 2 1 (P) 3 (R) 1 (P) 3 (R) Component Parts Description Material Note No.
Tubing T S Coupler KK S Coupler/Stainless Steel (Stainless Steel 304) KKA Series T TU TH Material Nylon Polyurethane FEP (Fluoropolymer) Modified PTFE (Soft fluoropolymer) Super PFA PFA Metal One-touch Fittings KQB2 Stainless Steel 316 One-touch Fittings KQG2 TD TL TLM Stainless Steel 316 Insert Fittings KFG2 Fluoropolymer Fittings LQ 74 C O N T E N T S HRS090 Series Standard Type HRS HRS
Dimensions [mm] Model A B C D E F G H J K L M N P Q R S T U V W Weight [g]*1 Outer body dia.
Insert the piston in the T groove so that it will be hooked there. 4.
Insert the piston in the T groove so that it will be hooked there. 4.
R E O P 17 P T 21.5 27.5 A I R R G Y 7 R A I 8 17.5 32 8 42 Side A Side B Scale: 40% 12 Rotary Gripper Series MRHQ Construction Description Material Note Parts list No.
U3 U0 U1 U2 U3 S0 S1 S2 S3 Note 2) 2 to 16 stations Note 2) Note 2) Note 2) With cable (1.5 m) With cable (3 m) With cable (5 m) With cable (1.5 m) With cable (3 m) With cable (5 m) With cable (1.5 m) With cable (3 m) With cable (5 m) F kit F kit P kit J kit P kit J kit G kit 2 to 24 2 to 24 2 to 16 stations stations stations Note 1) Besides the above, F/P kit with different number of pins
5 $2$0 r w#1 @8 @2 t Air-hydro type #6 $5 $4 $6 Component Parts No.
side of A port Nil 1 8 01 Rc VFN Nil Rc G NPT NPTF C4 4 cassette P port: Rc 1/8 R port: Rc 1/8 A port: Rc 1/8 F N T Same side of A port S C6 6 cassette Valve stations Type S42 (Solenoids on the same side of A port) 01 1 station 20 20 stations P port: Rc 1/8 R port: Rc 1/8 A port: Rc 1/8 Common SUP/Individual EXH How to Order Type 21: Body ported (A port top ported) Applicable solenoid valve
AL.01 to AL.32 D.OUT1 ALARM CODE No.15 screen Contact output signal 1 maintenance MT.01 MT.01 to MT.05 D.OUT1 MANT CODE No.16 screen Contact output signal 2 function RMT 1 D.OUT2 SEL No.17 screen Contact output signal 2 operation A A/B D.OUT2 TYPE No.18 screen Contact output signal 2 alarm AL.01 AL.01 to AL.32 D.OUT2 ALARM CODE No.19 screen Contact output signal 2 maintenance MT.01
2) Standard: JMGPM WA + Stroke/2 Z X 4 x YY depth YL Bottom view 2 x P (Plug) WA + Stroke/2 Z 4 x MM depth ML 4 x OA through 4 x OB counterbore depth OL L (OL) 4 x NN through 2 x P (Plug) U X PW VA PE T R H 2 x P D GC GB S Q 2 x P (Plug) GA JC PD GD FB C + Stroke FA G K J A + Stroke [mm] Bore size Standard stroke A C D FA FB G GA GB GC GD H J JC K L MM ML NN 80 (56 x 2) 25, 50, 100 150,
S) (mm) Dimensions PB S Model LVD2-T LVD3-T LVD4-T LVD5-T PA 13 26 A B 26 29.5 Dimensions (mm) A B C D E F G H J K L M N P Q T U Model LVD2-T LVD3-T LVD4-T LVD5-T 30 30 61 56 14.5 104 35 13 4 20 44 7 30 6 31.5 17 M5 to 0.8 35 35 79.5 62 17.5 136 42.5 17.5 6 22 50 7 37 6 36 21 M5 to 0.8 35 35 82 62 20 137 45 17.5 6 22 50 7 39 6 36 21 M5 to 0.8 45 45 105.5 76 25 169.5 65 17.5 8 32 64 7 52 6
M N 4-O T Q 2-P AH AG S K W U L B AL I 4-AK hole R AA AP J X AB A Y + Stroke V AI Z + Stroke AJ For 4-AO AG AN AI Cutout window 100 piston rod end connection AM Mounting dimensions For standard strokes (mm) Bore size (mm) Stroke range (mm) O N M L K J I B AP AO AN AM AL AK AJ AI AH AG AB AA P A 75, 100 125, 150 200, 250 300 63 80 100 M12 x 1.75 depth 23 100 66 180 135 117 65 228 60 M12 234
Table 1 Moment of inertia Size Allowable kinetic energy (J) 10 0.00015 15 0.00025 20 0.0004 30 0.015 40 0.03 How to calculate the load energy E : Kinetic energy (J) I : Moment of inertia (kg m Speed (rad/s) : Rotation angle (rad) 1803.14 rad t : Rotation time (s) 1 E = I 2 2 2 = t Table 2 Safety operable rotation time adjustment range Size Rotation time ( s / 90) 10 0.03 to 0.5 15
Load (kg) Load (kg) 10 10 30 10 100 300 Speed (mm/s) Speed (mm/s) Speed (mm/s) 300 300 REA REB Stroke Stroke Speed REC CY Time Time Stroke P=0.5 MPa,M=10 kg P=0.3 MPa,M=10 kg M=10 kg M=30 kg V=300 mm/s V=100 mm/s CX MQ Model Recommended Speed Controllers Caution RHC RZQ Model Elbow type Straight type In-line type REC20 AS2201F-01-06-X214 AS2001F-06-X214 AS2301F-01-06-X214 REC25 AS2201F
Load (kg) Load (kg) 10 10 30 10 100 300 Speed (mm/s) Speed (mm/s) Speed (mm/s) 300 300 REA REB Stroke Stroke Speed REC CY Time Time Stroke P=0.5 MPa,M=10 kg P=0.3 MPa,M=10 kg M=10 kg M=30 kg V=300 mm/s V=100 mm/s CX MQ Model Recommended Speed Controllers Caution RHC RZQ Model Elbow type Straight type In-line type REC20 AS2201F-01-06-X214 AS2001F-06-X214 AS2301F-01-06-X214 REC25 AS2201F
C Single clevis type Cylinder D Double clevis type J Nylon tarpaulin T Center trunnion type Rod boot Lock unit auto switch type K Heat resistant tarpaulin Bore size Rubber bumper at both ends Nil Nil Without auto switch N 125 125mm Without bumpers Cushion Refer to the table below for applicable auto switch models.
(t) is given by the graph. Then, the charge time (T) for a 100 L tank: With the pressure increase ratio from 2.0 to 3.0, the charge time of 147 58 = 89 sec. (t) is given by the graph. Then, the charge time (T) for a 10 L tank: T = t x = 3.2 x = 32 (s). V 10 T = t x = 89 x = 89 (s).