Dd9 Applicable d L L1 m t Part no.
Z (Example) A80CZ 3 m . L (Example) A80CL None .
Please contact SMC regarding water resistant types with the above model numbers. 2 1 m lead wire is only applicable to the D-A93. None N (Example) H7CN Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Since there are other applicable auto switches than listed above, refer to page 111 for details.
Lead wire length symbols: 0.5 m Nil (Example) A54 3 m L (Example) A54L 5 m Z (Example) A54Z In addition to the models in the above table, there are some other auto switches that are applicable.
Symbol 25 (L) Lead wire length Output specifications NPN output Analog output PNP output NPN output Analog output PNP output Applicable switch Lead wire length 0.6 (3.0) m 26 (L) Lead wire length 0.6 (3.0) m 65 (L) Lead wire length 0.6 (3.0) m 27 (L) Lead wire length 0.6 (3.0) m D1 D2 Ex.) ZR1--CN . 1 pc.
Standard Type: CXS Vertical mounting L L Mounting orientation m m up to 300 up to 400 up to 700 ( up to 800) up to 200 up to 600 up to 100 Max. speed (mm/s) Stroke (mm) All strokes 1 2 6 10 15 Selection graph 3 4 5 6 20 25 32 Horizontal mounting L Mounting orientation m m Refer to the caution notes below.
L M Nylon Urethane M5 X 0.8 Tube O.D.
2 x Rc P 4 x FD J MM FY BB D E e Air release K F MA l C Width across flats G f Air release 10 NA FT A SS NB B SS + Q + l S + Stroke FX M H ZZ + Stroke ZZ + Q + l + Stroke FZ (mm) With rod boot Stroke range (mm) Bore size (mm) l e J B BB C F GA GB M NA NB P R S FD FT FX FY FZ SS f Q B-rod C-rod B-rod C-rod 32 27 15 M10 x 1.25 25 to 1400 58 16 21 15 11 37 31 3/8 39 130 11 11 88 40 109 30
E E CRQ2X MSQX L L MRQ K K D B C G G D B C N N 1 M T T M 25.5 (34.5: Connector type) 2 x R Auto switch 2 x R Y Y Auto switch W W1 Size: 20, 30 Size: 40 W W 2 67 8 8 15 32.5 When D-M9m is used 65 4 *1.
MY1CW MY1MW 200 200 (kg) (kg) 190 190 (2100) (2100) (2100) (2100) 180 180 170 170 160 160 m 150 150 140 140 (2400) (2400) (2400) (2400) 130 130 L (1800) (1800) (1800) (1800) 120 120 Mass (m) Mass (m) 110 110 MY1MW63 MY1MW63 100 100 (2000) (2000) (2000) (2000) 90 90 m L (1500) (1500) (1500) (1500) MY1CW63 MY1CW63 MY1MW50 MY1MW50 80 80 m (1600) (1600) (1600) (1600) 70 70 MY1CW50 MY1CW50 MY1MW40
The spacing (L) of the support must be no more than the values shown in the below graph. MY2 H/HT MY3A MY3B m (800) MY3M 50 L (600) 40 m L 30 MY1H40 (550) Mass m (kg) m MY1H32 20 L L MY1H25 10 Caution 1. If the cylinder mounting surfaces are not measured accurately, using a side support may cause poor operation. Therefore, be sure to level the cylinder tube when mounting it.
1361213613PVQ Note 1) In the case of A1 and B1, a pressure gauge or a plug is mounted on the body side, while in case of A2 and B2, on the manifold side.
GA 2-RcP 4-FD J R MM FY BB D E e Air release K F Width across flats G MA l C f Air release 10 NB NA FT A SS B SS + Q + l + Stroke S + Stroke FX H M ZZ + Stroke ZZ + Q + l + Stroke FZ (mm) With rod boot Bore size (mm) Stroke range (mm) l J B BB C F GA GB M NA NB P R S FD FT FX FY FZ SS e f Q 32 M10 x 1.25 58 62 38 14 21 15 11 37 31 3/8 39 130 11 13 88 40 109 30 52 21.5 15 25 to 1400 1/3.5
Lead wire length symbols: 0.5 m Nil (Example) A54 3 m L (Example) A54L 5 m Z (Example) A54Z Since there are other applicable auto switches than listed, refer to page 6-9-30 for details.
(Example)A93 3 m L (Example)A93L 5 m Z (Example)M9NZ Auto switches marked with are produced upon receipt of order.
A water-resistant type cylinder is recommended for use in an environment which requires water resistance. 2 The 1 m lead wire is only applicable to the D-A93. Lead wire length symbols: 0.5 m Nil (Example) M9NW 3 m L (Example) M9NWL 1 m M (Example) M9NWM 5 m Z (Example) M9NWZ Solid state auto switches marked with are produced upon receipt of order.
Hexagon Socket Head Male Connector: KGS H (width across flats) Connection thread R Model L A M Effective area (mm2) Nylon Urethane Applicable tubing O.D.
Made to Order How to Order Transition wiring cable length IZS41 CF X13 For IZS40 Cable full length 1 m 3 m Symbol 01 03 Model with Made-to-order transition wiring cable Available in 1 m increments from 1 m to 20 m. Note 1) 11 m or longer power cables are not CE Marking-compliant. Note 2) Use standard power supply cables for 2 m, 5 m and 8 m lengths.