Lead wire length symbols: 0.5 mNil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ None N (Example) H7CN -X Individual -X Since there are other applicable auto switches than listed, refer to page 1214 for details. For details about auto switches with pre-wired connector, refer to pages 1784 and 1785.
Clevis pin and knuckle pin Rod end nut 30 d Dd9 d D C l m m t t L H B (mm) (mm) Part no. Size 25 32 40 50 l 18.2 22.2 26.2 32.2 Size 25 32 40 50 Part no.
(mm) 4 4 6 6 8 10 Piston rod thread M4 x 0.7 M4 x 0.7 M6 x 1 M6 x 1 M8 x 1.25 M10 x 1.25 Space-saving Port size M 5 x 0.8 M 5 x 0.8 M 5 x 0.8 M 5 x 0.8 G 1/8 G 1/8 Mounting accuracy and rigidity made possible by means of faucet joint and direct mounting.
(mm) 4 4 6 6 8 10 Piston rod thread M4 x 0.7 M4 x 0.7 M6 x 1 M6 x 1 M8 x 1.25 M10 x 1.25 Space-saving Port size M 5 x 0.8 M 5 x 0.8 M 5 x 0.8 M 5 x 0.8 G 1/8 G 1/8 Mounting accuracy and rigidity made possible by means of faucet joint and direct mounting.
Please consult with SMC regarding water resistant types with the above model numbers. 2 1 m type lead wire is only applicable to D-A93. Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 5 m Z (Example) M9NWZ None N (Example) H7CN 3 m L (Example) M9NWL Since there are other applicable auto switches than listed above, refer to page 14 for details.
Do not use a cable longer than 10 m. Wire the DC (-) line as close as possible to the power supply.
Lead wire length symbols: 0.5 mNil 3 m L 5 m Z None N (Example) C73C (Example) C73CL (Example) C73CZ (Example) C73CN Since there are other applicable auto switches than listed, refer to page 10-15-6 for details.
Lead Wire with Connector Length 0.5 m 3 m 5 m Part no. D-LC05 D-LC30 D-LC50 6-10-44 45 Auto Switch Series C76 Contact Protective Box/CD-P11, CD-P12 Differential Response of Auto Switch The auto switch of D-A7/A8 type, D-A7H/A80H type, D-A73C/A80C type, D-C7/C8 type, D-C73C/C80C type are not incorporated with a contact protective circuit.
Lead Wire with Connector Length 0.5 m 3 m 5 m Part no. D-LC05 D-LC30 D-LC50 6-10-44 45 Auto Switch Series C76 Contact Protective Box/CD-P11, CD-P12 Differential Response of Auto Switch The auto switch of D-A7/A8 type, D-A7H/A80H type, D-A73C/A80C type, D-C7/C8 type, D-C73C/C80C type are not incorporated with a contact protective circuit.
L 5 m Z None N Solid state switches marked with are produced upon receipt of order.
DIN connector VFR Lubrication Non-lube If provided, use turbine oil (ISO, VG32) 150/50 m/s2 VP7 Shock resistance (Vibration resistance) (1) Applicable sub-plate VS7-1 (ISO size q) Option Note) Shock resistance: No malfunction resulted from the impact test using a drop impact tester.
3 m 5 m None Solid state switches marked with are produced upon receipt of order.
Do not use a cable longer than 30 m. Wire the DC (-) line (blue) as close as possible to the power supply.
M M M-03 03 03 03-3 3 3 3 0.1Nm 2 A B 1.7 ON OFF A B VQ1000 2 DC DC DC DC 2 ON OFF ON OFF 1.7 VQ20002 A B .
I Auto 8witCN' D-90'0-97 Note)The Bmm bore cylinder is nol repairable. o Series CJP -~ D~--n-~-( -m) ,-.-I ~ ime-sions~m ~-~~~--~-Nose mount: CO JPB u \2~ . c: n p w , ,," B' p I./l,ao~ hab ,/ (' B Rod end without thread w ",. /"(2 " .' ,," / ro~ ~ e ~With , autO sw.itCh Bore size w i (mm) 15S): 20~t ; .
10-32 thread) 1/8MMV-44-22L (Figure 2) signifies a V type 1/8 NPT manifold fitting with two #4 branches and two #2 branches on each row with the second row to the right as viewed from the threaded end. 1 8 1 (Figure 1) 7 16 1 3 8 Typ. 13/16 1 4 1 4 1 8 5 16 5 16 5 16 1 8 1 4 1 4 5 16 3 8 1 8 35/64 7/16 17/32 7/16 Hex Typ. 7 16 75 1/8 M-111 or 1/8 M-222 1/8 M-3 1/8 MM-44222
Plug Connector How to Use L/M Plug Connector How to Order 2. Crimping connection of lead wire and socket Caution L/M Plug Connector For JSY1000 Strip 3.2 to 3.7 mm at the end of lead wires, insert the end of the core wires evenly into the sockets, and then crimp it by a crimping tool.
B: Locking style (Slotted) : Non-locking push style (Flush) VP 4 1 (P) 3 (R) VQ VQZ Body style 2 Body ported Electrical entry VZ G: Grommet (DC Specification) L: L plug connecor with lead wire M: M plug connecor with lead wire MO: M plug terminal without connector LO: L plug terminal without connector VS Function Symbol Specification DC AC (1.0W) (3) Standard (1) High pressure (Metal seal
Locking type manual override While pressing the M/O knob, turn it 90 counter clockwise. When the mark on the cap is aligned with the OFF mark on the M/O knob, the lock will be released (the lock will remain in a released condition). To operate the lock, turn the M/O knob 90 clockwise while pressing it all the way down, and align the cap's mark with the M/O knob's ON mark.
Do not receive a moment force on the nozzle (Page 6). 9 Doc. no.IZ-OMV0005 1-2.Accessories Power supply cable IZN10E CP Z Symbol Type Nil 3m Z 10m Made-to-Order power supply cable Available from 1 to 20 m in 1 m increment (use standard for 3 m and 10 m).