Controller Series: LECP1 (Programless Controller), Parallel I/O Type: P (PNP), I/O Cable Length, m: 5, Actuator Series: LEY (Rod Type), Size: 25, Motor Mounting Position: D (In-Line Type), Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32: 16mm), Stroke: 100mm
Controller Series: LECP1 (Programless Controller), Parallel I/O Type: P (PNP), I/O Cable Length, m: w/o Cable, Actuator Series: LEY (Rod Type), Size: 25, Motor Mounting Position: D (In-Line Type), Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32: 16mm), Stroke: 200mm
Controller Series: LECP1 (Programless Controller), Parallel I/O Type: P (PNP), I/O Cable Length, m: w/o Cable, Actuator Series: LEY (Rod Type), Size: 25, Motor Mounting Position: D (In-Line Type), Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32: 16mm), Stroke: 300mm
Controller Series: LECP1 (Programless Controller), Parallel I/O Type: P (PNP), I/O Cable Length, m: 1 (1.5), Actuator Series: LEY (Rod Type), Size: 25, Motor Mounting Position: D (In-Line Type), Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32: 16mm), Stroke: 50mm
Controller Series: LECP1 (Programless Controller), Parallel I/O Type: P (PNP), I/O Cable Length, m: 1 (1.5), Actuator Series: LEY (Rod Type), Size: 25, Motor Mounting Position: D (In-Line Type), Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32: 16mm), Stroke: 150mm
Controller Series: LECP1 (Programless Controller), Parallel I/O Type: P (PNP), I/O Cable Length, m: 3, Actuator Series: LEY (Rod Type), Size: 25, Motor Mounting Position: D (In-Line Type), Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32: 16mm), Stroke: 200mm
Controller Series: LECP1 (Programless Controller), Parallel I/O Type: N (NPN), I/O Cable Length, m: 3, Actuator Series: LEY (Rod Type), Size: 25, Motor Mounting Position: D (In-Line Type), Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32: 16mm), Stroke: 150mm
Controller Series: LECP1 (Programless Controller), Parallel I/O Type: P (PNP), I/O Cable Length, m: w/o Cable, Actuator Series: LEY (Rod Type), Size: 25, Motor Mounting Position: D (In-Line Type), Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32: 16mm), Stroke: 150mm
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
Size: 25, Motor Mounting: D (In-line Type), Motor Type: Step Motor, Servo/24 VDC, Lead: A (LEY25, 12; LEY32/40, 16), Stroke: 300mm, Motor: w/o Lock, Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped, Body Bottom Tapped, Actuator Cable Length: 3m, Controller Type (LEC, JXC): C91 (JXC91, EtherNet/IPâ„¢ Direct Input Type), I/O Cable Length for LEC: w/o Cable, Controller Mounting:
Size: 25, Motor Mounting: D (In-line Type), Motor Type: Step Motor, Servo/24 VDC, Lead: A (LEY25, 12; LEY32/40, 16), Stroke: 300mm, Motor: w/o Lock, Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped, Body Bottom Tapped, Actuator Cable Length: 3m, Controller Type (LEC, JXC): CE1 (JXCE1, EtherCAT®), I/O Cable Length for LEC: w/o Cable, Controller Mounting: 7 (Screw Mounting), Communication
Size: 25, Motor Mounting: D (In-line Type), Motor Type: Step Motor, Servo/24 VDC, Lead: A (LEY25, 12; LEY32/40, 16), Stroke: 300mm, Motor: w/o Lock, Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped, Body Bottom Tapped, Actuator Cable Length: 3m, Controller Type (LEC, JXC): 1N (LECP1, Programless Type, NPN), I/O Cable Length for LEC: 3 (3m), Controller Mounting: D (DIN Rail Mounting
Size: 25, Motor Mounting: In-line Type, Motor Type: Step Motor, Servo/24 VDC, Lead: LEY25, 12; LEY32, 16, Stroke: 100mm, Motor: w/o Lock, Rod End Thread: Rod End Female Thread, Mounting: Body Bottom Tapped, Actuator Cable Length: 5m, Controller Type: LECP1, Programless Type, PNP, I/O Cable Length: 5m, Communication Plug Connector: None, Controller Mounting: DIN Rail Mounting
Size: 25, Motor Mounting: In-line Type, Motor Type: Step Motor, Servo/24 VDC, Lead: LEY25, 12; LEY32, 16, Stroke: 100mm, Motor: w/o Lock, Rod End Thread: Rod End Female Thread, Mounting: Body Bottom Tapped, Actuator Cable Length: 5m, Controller Type: w/o Controller, I/O Cable Length: w/o Cable, Communication Plug Connector: None, Controller Mounting: Screw Mounting
Size: 25, Motor Mounting: In-line Type, Motor Type: Step Motor, Servo/24 VDC, Lead: LEY25, 12; LEY32, 16, Stroke: 200mm, Motor: w/o Lock, Rod End Thread: Rod End Male Thread, 1 Rod End Nut Included, Mounting: Body Bottom Tapped, Actuator Cable Length: 3m, Controller Type: w/o Controller, I/O Cable Length: w/o Cable, Communication Plug Connector: None, Controller Mounting: Screw Mounting
Size: 25, Motor Mounting: In-line Type, Motor Type: Step Motor, Servo/24 VDC, Lead: LEY25, 12; LEY32, 16, Stroke: 300mm, Motor: w/o Lock, Rod End Thread: Rod End Male Thread, 1 Rod End Nut Included, Mounting: Body Bottom Tapped, Actuator Cable Length: 3m, Controller Type: w/o Controller, I/O Cable Length: w/o Cable, Communication Plug Connector: None, Controller Mounting: Screw Mounting
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Enclosure: IP65
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Enclosure: IP65
Size: 25, Motor Mounting: D (In-line Type), Motor Type: Step Motor, Servo/24 VDC, Lead: A (LEY25, 12; LEY32/40, 16), Stroke: 200mm, Motor: B (w/Lock), Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut Included), Mounting: Ends Tapped, Body Bottom Tapped, Actuator Cable Length: 5m, Controller Type (LEC, JXC): C91 (JXC91, EtherNet/IPâ„¢ Direct Input Type), I/O Cable Length for LEC: w/o