size Lubrication Model Rubber Air M3 x 0.5 12-CY3B6 6 300 50, 100, 150, 200 M5 x 0.8 12-CY3B10 10 500 50, 100, 150, 200, 250, 300 15 1000 12-CY3B15 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 12-CY3B20 20 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 Rc1/8 NPT1/8 G1/8 25 12-CY3B25 (Both sides) Non-lube 32 12-CY3B32 1300 Rc1/4 NPT1/4 G1/4 12-CY3B40 40 100, 150, 200, 250
Standard Stroke Bore size (mm) Standard stroke (mm) Maximum available stroke (mm) Made to Order: Individual Specifications (For details, refer to pages 1538 and 1539.) 6 10 300 500 50, 100, 150, 200 50, 100, 150, 200, 250, 300 50, 100, 150, 200, 250, 300, 350 400, 450, 500 Symbol Specifications -X116 -X168 -X322 -X431 Hydro specifications 15 750 Helical insert thread specifications 20 25
Count Pressure Characteristics Flow Characteristics Supply pressure: 0.6 MPa Set pressure: 0.25 MPa 600 1 500 kPa 500 Output deviation factor (% F.S.) 0.5 Set pressure (kPa) 400 kPa 400 Out 300 kPa 300 0 Return 200 kPa 200 0.5 100 kPa 100 50 kPa 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 0 2 1 3 4 5 6 0 7 1.0 Supply pressure (MPa) Flow rate (l/min (ANR)) 14-8-6 7 Compact Electro-pneumatic Regulator
300 600 600 D L1 Note) When a copper extension nozzle is ordered separately, a self-align fitting will also be required for connection with the blow gun.
Air consumption (l/min (ANR)) 140 120 SUP = 0.5 MPa 100 SUP = 0.3 MPa 80 SUP = 0.2 MPa 60 40 20 1 0 2 3 4 5 6 7 Cycle (Hz) PA513 Air Consumption 400 Air consumption (l/min (ANR)) SUP = 0.5 MPa 350 300 Calculating Air Consumption (PA3000) 250 SUP = 0.3 MPa 200 Find the air consumption for operation with a 4 Hz switching cycle and pilot air pressure of 0.3 MPa from the air consumption graph
Grommet: G Conduit: C 300 V D D F Q F Q 280 300 VC Class H coil Broken line section C C G1/2 R R VDW VQ E E VX2 A H A H B B 2-P Port size 2-P Port size VX 2-M, thread depth N 2-M, thread depth N Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com VX3 L L VXA K K VN
Grommet: G Conduit: C Approx. 300 Approx. 280 D D Q F Q F C C G (PF) 1/2 R R E E A H 2-P Port size 2-M B B A H 2-P Port size 2-M L L K K DIN connector: D Conduit terminal: T Cable 6.8 to 10 27.5 F F Q (Q) S 34 25 U R C R C (44) G (PF) 1/2 E B A H D 2-P Port size (S) E G (PF) 1/2 B A H D 2-M 2-P Port size 2-M L L K K N.C.
VEX AN AMC Effective area (mm2) Model Connection R(PT) Max.air flow (l/min) AMC310 300 3 8 16 55 165 330 550 AMC510 1,000 3 4 AMC610 AMC810 AMC910 3,000 1 1 6,000 10,000 1 2 2 99.9% of oil mist removal. Over 35dB noise reduction. Refer to p.5.3-1 for details. 5.1-36
Model Position /No. of solenoid Type Port size {NPTD Cv factor MaKOperating cycle CPM Response time (ms) Weight lbs (ks0 Plug-in Non Piug-in 2 position Single wFR2100 NVFR2110 Va 300 20 or less 0.75 (0.34) V1 Double wFR2200 NVFR2210 la 0.9 300 20 or less o.92 (0.421 Y.
N217 3 Way Direct Acting NVKF 300 series Rubber Seal Solenoid Valve Compact Size I Large Flow Capacity Low Power Option Available Vacuum Option Available Base Mounted or Body Ported Cv 0.25 Sries ]tlUlff 300 3-Porl / 0irscl Wmhil $hruid hlYe I Large Flow Capacity Cv 0.25 I Compact Size width 0.73" x length 2.67" I Low Power Consumption 4WDC (Standard model) 2WDC (Low wattage model) I Vacuum
Series LECP6 controller has two available modes for the setting software and teaching box. In the easy mode, the operation can be started by only setting the speed, position, etc. Using the normal mode allows a further detailed setup. A few of the main functions of the LECP6 controller are actuator control, specified force operation, separated power supply, and returning the actuator
Series LECPA pulse input driver, combined with a 24 volt step motor, permits control of position, speed, acceleration and deceleration using pulse signals. The LECPA is a step motor driver compatible with a variety of SMC's electric actuators including the LEY, LEF, LES, LER and LEP series.Step motor driver , Pulse input type , For step motor, NPN DC Pulse Step Controller, ELECTRIC ACTUATOR
EtherNet/IP Direct Connect, ELECTRIC ACTUATOR CONTROLLER, 0.13 lb
Series LECP6 controller has two available modes for the setting software and teaching box. In the easy mode, the operation can be started by only setting the speed, position, etc. Using the normal mode allows a further detailed setup. A few of the main functions of the LECP6 controller are actuator control, specified force operation, separated power supply, and returning the actuator
Series LECP6 controller has two available modes for the setting software and teaching box. In the easy mode, the operation can be started by only setting the speed, position, etc. Using the normal mode allows a further detailed setup. A few of the m, PNP DC Step Motor Controller, ELECTRIC ACTUATOR, 0.15 lb
IO-LINK DC CONTROLLER, ELECTRIC ACTUATOR CONTROLLER, N31, 0.21 lb
ETHERNET/IP DC CONTROLLER, ELECTRIC ACTUATOR CONTROLLER, N31, 230 lb
Series LECP6 controller has two available modes for the setting software and teaching box. In the easy mode, the operation can be started by only setting the speed, position, etc. Using the normal mode allows a further detailed setup. A few of the main functions of the LECP6 controller are actuator control, specified force operation, separated power supply, and returning the actuator
Series LECP6 controller has two available modes for the setting software and teaching box. In the easy mode, the operation can be started by only setting the speed, position, etc. Using the normal mode allows a further detailed setup. A few of the main functions of the LECP6 controller are actuator control, specified force operation, separated power supply, and returning the actuator
MPa) Operating Parameters Operating pressure Gas Proof pressure (Inlet) Burst pressure Ambient and operating temperature Cv Leak rate Connections Installation Internal volume Mass Select compatible materials of construction for the gas 15 psig (0.105 MPa) 30 psig (0.2 MPa) 45 psig (0.3 MPa) 90 psig (0.6 MPa) 90 psig (0.6 MPa) 180 psig (1.2 MPa) 150 psig (1.05 MPa) 300 psig (2.1 MPa) 300 psig