2 port 3 port 28 17 20.5 28 20.5 17 20.5 28 20.5 VDW10 VDW20 VDW30 VDW200 VDW300 2 Compact Direct Operated 2 Port Solenoid Valve for Water and Air Series VDW10/20/30 How to Order Valves (Single Type) VD W 2 1 1 G 2 01 For water, air and vacuum Series Option 1 2 3 10 20 30 None Foot type bracket Nil F Note) Foot brackets are packed with valves.
Bore 1/32 1/16 1/8 1/4 3/8 1/2 3/4 1 1 6 15 37 1-1/8 5 12 28 85 1-1/2 3 7 16 50 2 4 9 28 70 2-1/2 6 18 45 72 3 4 12 30 48 3-1/4 3 10 24 37 79 4 7 17 28 60 5 4 11 18 40 82 6 3 7 12 26 55 8 4 7 15 32 10 4 9 20 12 3 6 14 NOTE: These values are an approximate speed, under average conditions, where the force required is 50% of available 80-100 PSI inlet pressure, the directional valve internal
Applicable model Minimum operating ow rate (50/60 Hz) HRS-BP007 HRS1007.4/11.0 gal/min [28/42 L/min] HRS150q To circulating fluid return port y To circulating fluid outlet r t w u r t r e r Parts List No.
Bore 1/32 1/16 1/8 1/4 3/8 1/2 3/4 1 1 6 15 37 1-1/8 5 12 28 85 1-1/2 3 7 16 50 2 4 9 28 70 2-1/2 6 18 45 72 3 4 12 30 48 3-1/4 3 10 24 37 79 4 7 17 28 60 5 4 11 18 40 82 6 3 7 12 26 55 8 4 7 15 32 10 4 9 20 12 3 6 14 NOTE: These values are an approximate speed, under average conditions, where the force required is 50% of available 80-100 PSI inlet pressure, the directional valve internal
center SYJA3330 (0.067) M5 X 0.8 3 position exhaust center SYJA3430 28 3 position pressure center SYJA3530 Body ported Note 1) Value when used on a manifold.
2 port 3 port 28 17 20.5 28 20.5 17 20.5 28 20.5 VDW10 VDW20 VDW30 VDW200 VDW300 2 Compact Direct Operated 2 Port Solenoid Valve for Water and Air Series VDW10/20/30 How to Order Valves (Single Type) VD W 2 1 1 G 2 01 For water, air and vacuum Series Option 1 2 3 10 20 30 None Foot type bracket Nil F Note) Foot brackets are packed with valves.
L 285.5 21 273 310.5 23 298 22 335.5 25 323 24 360.5 27 348 26 385.5 29 373 28 410.5 31 398 30 435.5 33 423 32 460.5 35 448 34 485.5 37 473 36 39 498 38 40 510.5 Fitting blank plug KQP-23-X19 KQP-04-X19 KQP-06-X19 KQP-08-X19 KQP-10-X19 L A Dimensions (mm) Applicable fitting d Part number A L D D KQP-23-X19 KQP-04-X19 KQP-06-X19 KQP-08-X19 KQP-10-X19 3.2 4 6 8 10 16 16 18 20.5 22 31.5 32
Applicable model D5 L9 L10 L11 L12 L13 L14 L15 L16 L17 t1 AS-10L AS1002FS3.4 14.8 18.3 11 27.5 19.5 3.4 4.9 7.3 12 1 AS-20L AS2002FS 15.6 19.6 12.6 29 21 1.2 AS-25L AS2052FS 19.6 24.6 17 38 28 AS-30L AS3002FS4.5 24.8 29.8 22 43 33 4.5 6.5 9.5 15.5 1.4 AS-40L AS4002FS 25.7 30.7 28 49 39 Part no.
13 10.4 21.8 32.1 36.4 63.1 61.7 57.9 56.5 13.3 24.5 28.5 9.3 19.2 47 (48) AS321FS-02-08 (S) 8 13.2 22.7 33 14.2 AS321FS-02-10 (S) 10 15.9 26.7 37 35.7 15.6 38 (39) AS321FS-02-12 (S) 12 18.5 29.7 40 34.5 17 50 (51) AS321FS-03-06 (S) 6 1/4 19 16.6 10.4 21.8 32.1 28.7 55.4 54 50.2 48.8 13.3 24.5 28.5 9.3 19.2 38 (39) AS321FS-03-08 (S) 8 13.2 22.7 33 14.2 AS321FS-03-10 (S) 10 15.9 26.7 37 28
B C E G H K MM NN 5 st 10 st F 15 st R 5 st 10 st S 15 st W Q 5 st 10 st Z Bore size (mm) 6 10 15 A 15 st M3 x 0.5 3.5 3 8.5 9 41.5 26.5 34.5 19.5 27.5 12.5 3 6 32.5 13.9 25.5 12 18.5 7 M10 x 1.0 9 M4 x 0.7 3.5 5 12 46 28 39 21 32.5 14.5 4 6 34 22 27 19 20.5 10 M15 x 1.5 13 12 M5 x 0.8 4.2 6 14 50 29 43.5 22.5 37.5 16.5 5 7 36 31 29.5 27 23.5 12 M22 x 1.5 20 19 6-2-16
Switch Specifications Load voltage Load current range Indicator light Applicable load Type Auto switch model 24 VAC or less, 48 VAC or less, 100 VAC or less 24 VDC or less, 48 VDC or less, 100 VDC or less 50 mA, 40 mA, 20 mA IC circuit, Relay, PLC No Reed auto switch D-A90 D-M9B, D-F8B D-M9N, D-F8N 2-wire 3-wire 24 VDC relay, PLC 24 VDC relay, PLC Solid state auto switch Yes 24 VDC (10 to 28
14 15 18 20 5 5 8 19 21 27 30 19 21 27 30 34.5 37 42 47.5 34.5 35.5 42 47.5 CQ-C012 CQ-C016 CQ-C020 CQ-C025 25 28 35 40 25 28 35 40 100 100 4 4 5 5 4 4 5 5 12 16 20 25 12 16 20 25 45.5 49 54 57.5 39.5 40.5 52 57.5 CQ2 80 90 10 5 5 8 CQ-C012 CQ-C016 CQ-C020 CQ-C025 100 100 CQS 80 90 10 The double clevis pin and retaining ring are not included.
N.O. 13.5 SYA 12 NC 26.2 65.2 58.2 3R 58.2 27 50 50.1 65.2 SYJA 1P 26.2 NO 12 VZA 1/4 1(P), 3(R) port 1/8 (Pitch) P = 27.5 12(PA) port 28 M5 x 0.8 (Breathing hole) VFA 7.5 L2 L1 VFRA (Station n) (Station 1) 1/8 12(PA) port VPA4 12 SYJA 73.5 54 VZA 37.5 11 2A 2A VTA 1/4 2(A) port (Pitch) P = 27.5 28 VGA 2 stations 83.5 68.5 111 96 138.5 123.5 166 151 193.5 178.5 221 206 248.5 233.5 276 261
VV5Q11 (L4) (L3) L2 (5.25) (12) 13 27 28 L1 Indicator light 63.5 23.5 10.5 (n-1) x 10.5 1.5 Manual override A A A B A B A B A B A FG + + 0V 24V SMC S E R I A L U N I T MODEL SC (SI No.EX120-STA1) 2 93.5 66 64 ERR T/R RUN (35) (5.5) 0 1 DIP SW. 4 x M4 mounting hole 61.5 4.5 Drawing shows a SC case.
(Red Green Red) Auto switch model D-M9NJ D-M9PJ Output type NPN PNP Power supply voltage 5, 12, 24 VDC (4.5 to 28 V) Current consumption 25 mA or less Load voltage 28 VDC or less Load current 40 mA or less Internal voltage drop 0.8 V or less Leakage current 100 mA or less at 24 VDC Indicator light Operating range . Red LED illuminates Optimal operating range .
150 JAL140-30-150 JAL160-36-150 8 10 14 18 22 26 30 36 44 52 67 82.5 98.5 123 187 213 21 24 31 41 50 59.5 79 96 44 48 38 44 57.5 71.5 86 107 125 144 8 9 13 15 18 24 38 42 1.25 1.25 1.5 1.5 1.5 1.5 1.5 1.5 0.5 0.5 0.75 1 1.25 2 2.5 3 18 24 30 34 42 48 60 74 1000 2000 4400 9000 14000 22000 36000 55000 12 16 19 22 25 32 80 90 19 25 30 38 47 58 79 89 30 42 52 56 70 80 96 116 11.5 14 17.5 23 28
with double knuckle joint. +0.058 0 +0.058 0 +0.070 0 +0.084 0 +0.084 0 0.10 0.30 0.10 0.30 0.10 0.30 0.10 0.30 0.10 0.30 14 19 24 26 26 20 22 28 40 40 30 40 50 60 60 M10 x 1.25 16 19 24 34 34 M10 x 1.25 10 11 14 20 20 16 19 24 34 34 40 50 64 80 80 10 10 14 22 22 14 14 20 30 30 28 28 40 60 60 10 10 14 22 22 14 14 20 30 30 12 M14 x 1.5 M14 x 1.5 12.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 M18 x 1.5
B C E G H K MM NN 5 st 10 st F 15 st R 5 st 10 st S 15 st W Q 5 st 10 st Z Bore size (mm) 6 10 15 A 15 st M3 x 0.5 3.5 3 8.5 9 41.5 26.5 34.5 19.5 27.5 12.5 3 6 32.5 13.9 25.5 12 18.5 7 M10 x 1.0 9 M4 x 0.7 3.5 5 12 46 28 39 21 32.5 14.5 4 6 34 22 27 19 20.5 10 M15 x 1.5 13 12 M5 x 0.8 4.2 6 14 50 29 43.5 22.5 37.5 16.5 5 7 36 31 29.5 27 23.5 12 M22 x 1.5 20 19 6-2-16
For dimensions of 25 stroke, refer to page 8-26-28. Note 2) For 25 stroke, the shock absorber is mounted on a single side of the plate.