D-X 100 Lateral load F (N) 2080 10 Data 63 50 Operating pressure 0.5 MPa Operating pressure 0.4 MPa 40 32 25 Graph (1) 1000 20 1 10 100 300 Stroke + Eccentric distance (mm) Cushion Needle Adjustment 100 100 Load weight kg Caution 80 63 50 1.
How to Order Integrated Display Type PF2A7 10 01 27 Flow rate range Thread type Unit specification 1 to 10l/min 5 to 50l/min 10 to 100l/min 20 to 200l/min 50 to 500l/min 10 50 11 21 51 Nil M Wiring specification With unit switching function Fixed SI unit Note) Nil N F Rc NPT G 3m lead wire with connector Without lead wire Nil N Note) Fixed units: Real-time flow rate: l/min Accumulated flow
LG1H202200-F LG1H202300-F LG1H202400-F LG1H202500-F LG1H202600-F LG1H202700-F LG1H202800-F LG1H202900-F LG1H202-1000-F LG1H202-1200-F 100 200 300 400 500 600 700 800 900 1000 1200 245.7 345.7 445.7 545.7 645.7 745.7 845.7 945.7 1045.7 1145.7 1345.7 400 500 600 700 800 900 1000 1100 1200 1300 1500 50 150 250 350 450 550 650 750 850 1050 70 170 270 370 470 570 670 770 870 1070 Note) Dimensions
(For details, refer to catalog on page 22.) 17 Series SYJ500 Construction c f a e b d c f a e b d N.C. N.O.
Pipe thread type Nil Rc F GWith Rc-G conversion fitting set N NPTWith Rc-NPT conversion fitting set Option1 *2 Power supply Nil None 10 Single-phase 100VAC (50/60) DM With electric conductivity control function, Single-phase 115VAC (60Hz) Applicable to DI water piping 20 Single-phase 200 to 230VAC (50/60Hz) M Applicable to DI water piping T High-pressure pump mounted *3 T1 Inverter pump mounted
1) 5 to 55 (23 to 131) Ambient temperature C (F) 5 to 50 (23 to 122) 5 to 55 (23 to 131) 5 to 50 (23 to 122) Outlet air atmospheric pressure dew point C (F) Standard performance 20 (-4) Inlet air flow rate l/min (ANR) (SCFM) Note 2) 625 (22.0) 62 (2.19) 125 (4.41) 250 (8.82) 375 (13.24) Outlet air flow rate l/min (ANR) (SCFM) 50 (1.8) 100 (3.5) 200 (7.1) 300 (10.6) 500 (1.77) Purge air flow
Contact P/A regarding the specifications for PSI unit and F .
14 189 12 15 5 25 50 59.6 35 6 106.5 84 50 224 204 CG-E050SUS 63 14 189 12 15 5 25 50 59.6 35 6 106.5 84 50 224 204 CG-E050SUS 80 22 234 14 23 6 40 80 87.2 57 9 144.5 120 80 291 257 CG-E080SUS 100 22 235 14 23 6 40 80 87.2 57 9 144.5 120 80 292 258 CG-E080SUS Plug bolts are installed when shipped from factory.
14 189 12 15 5 25 50 59.6 35 6 106.5 84 50 224 204 CG-E050SUS 63 14 189 12 15 5 25 50 59.6 35 6 106.5 84 50 224 204 CG-E050SUS 80 22 234 14 23 6 40 80 87.2 57 9 144.5 120 80 291 257 CG-E080SUS 100 22 235 14 23 6 40 80 87.2 57 9 144.5 120 80 292 258 CG-E080SUS Plug bolts are installed when shipped from factory.
14 189 12 15 5 25 50 59.6 35 6 106.5 84 50 224 204 CG-E050SUS 63 14 189 12 15 5 25 50 59.6 35 6 106.5 84 50 224 204 CG-E050SUS 80 22 234 14 23 6 40 80 87.2 57 9 144.5 120 80 291 257 CG-E080SUS 100 22 235 14 23 6 40 80 87.2 57 9 144.5 120 80 292 258 CG-E080SUS Plug bolts are installed before shipment from factory.
mg F F Gripping force at least 10 to 20 times the work piece weight The "10 to 20 times or more of the work piece weight" recommended by SMC is calculated with the safety margin of a = 4, which allows for impacts that occur during normal transportation, etc. 2F mg Number of fingers and therefore, mg F 2 x With "a" as the safety margin, F is determined as follows: mg F = x a 2 x When
sensor, F G (With Rc-G conversion fitting set) Z 1 no bypass valve,no particle filter, N NPT (With Rc-NPTconversion fitting set no water leakage sensor Power supply no flow sensor Z1 1 3phase 380 to 415VAC (50/60Hz) 3phase 460 to 480VAC (60Hz) 40 1 Only option Z or Z1 can be selected.
F ZZ + Stroke H B E G Mounting nut NN NA F N CY3B15 (mm) Model CY3B15 CY3B20 CY3B25 CY3B32 CY3B40 B 35 36 46 60 70 NA 17 24 30 36 46 R 28 34 40 50 S 83 106 111 124 150 W 35 50 50 50 60 X 19 25 30 40 40 D 16.6 21.6 26.4 33.6 41.6 ZZ 103 132 137 156 182 E 3 2 2 2 3 N 11 18 18.5 20 26 F 10 13 13 16 16 MM M4 x 0.7 M4 x 0.7 M5 x 0.8 M6 x 1 M6 x 1 G 5.5 7.5 7.5 8 11 NN M10 x 1 M20 x 1.5 M26 x
Extension locking Retraction locking Retraction locking Variations Bore size (mm) Standard stroke (mm) Locking direction Mounting Series 20 25 30 40 50 75 100 LOCK 32 Extension lock Through hole LOCK 40 RLQ LOCK 50 Retraction lock Both ends tapped 63 Compact Cylinder with Air Cushion and Lock Series RLQ 32, 40, 50, 63 How to Order B 32 50 M F RLQ B 32 50 M F F9BW RDLQ With auto switch Number
) EH5 kPa EH5 kPa EPL:25kPa EPH:50kPa -46No.PS-OMT0001CN-E 4 (1)(100 kPa200 kPa) (2) () (1) OUT1 (2) OUT1 1 () (3) OUT2 (4) [F 2](52 ) OUT [EPH] OUT [EPL] (5) -47No.PS-OMT0001CN-E 4 2 [F 0] [F] 2 [Function ][]] F 0(Unit) [ PA] kPa 49 ISA3-F[ 20] ISA3-G[ 50] ISA3-H[ 50] F 1(oUt1) OUT1 50 ISA3-F[ 3] ISA3-G[ 20] ISA3-H[ 20] [ SoG] ON OFF out2[ Ewin] OUT 2ot[ 2_P] F 2
0 Air operated, With solenoid valve XLAV e Indicator/Solenoid valve direction w Flange type q Flange size Symbol Indicator Solenoid valve direction F With indicator Size 16 25 40 50 63 80 Symbol Type Applicable flange size Nil KF (NW) 16, 25, 40, 50, 63, 80 D K (DN) 63, 80 Rear flange surface Left flange surface G Rear flange surface J Right flange surface K Without indicator Right flange
Thread type Voltage Rc G NPT Nil F N 1 2 3 4 5 6 100VAC (50/60Hz) 200VAC (50/60Hz) 110VAC (50/60Hz) 210VAC (50/60Hz) 24VDC 12VDC Port size Contact P/A regarding other voltages.
Thread type Voltage Rc G NPT Nil F N 1 2 3 4 5 6 100VAC (50/60Hz) 200VAC (50/60Hz) 110VAC (50/60Hz) 210VAC (50/60Hz) 24VDC 12VDC Port size Contact SMC regarding other voltages.
Time Accumulated pulse output mode 50 msec Time -35No.LV50***-OMQ0002-G [F 2] Setting of OUT2 Set the output mode of OUT2.
50 63 MGPA -150 50 63 MGPA -100 50 63 MGPA -200 0.2 MGPA16-75 MGPA16-75 50 63 MGPA -150 0.3 0.15 50 63 MGPA -100 MGPA16-50 MGPA16-50 0.2 0.1 MGPA16-10 MGPA16-10 0.1 0.05 50 63 MGPA -50 50 63 MGPA -50 0 0 0 10 20 30 0 20 40 60 80 100 Horizontal load N Horizontal load N MGPA20 MGPA80 0.45 0.7 MGPA80-400 MGPA80-400 MGPA20-400 MGPA20-400 0.4 0.6 Plate displacement mm Plate displacement mm 0.35