100 200 300 400 500 100 200 300 400 500 Piston speed (mm/s) Horizontal mounting Piston speed (mm/s) Vertical mounting Selection O.K. NO NO YES Is it possible for cable of stroke reading cylinder to be wired separately from the power line? Is there any influence of noise? YES NO YES NO Can the system be operated below 14.5 mT? Do not use it since it will result in a miscount.
Fittings & Tubing Air Cylinders Rotary Actuators ARP20(K) 1021 ARP20(K) 1021 Rc1/4 0.50 0.25 0.45 0.40 Outlet pressure (MPa) Outlet pressure (MPa) 0.35 Set point 0.30 0.20 0.25 0.20 0.15 0.10 0.05 0.15 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.00 0 50 100 150 200 250 300 Flow rate (L/min (ANR)) Inlet pressure (MPa) 1021 1021 ARP30(K) ARP30(K) Rc3/8 0.50 0.25 0.45 Air Preparation Equipment 0.40
15 600 500 400 300 200 100 20 200 400 600 800 1000 25 200 400 600 800 1000 1200 1400 Flow rate Q [kg/h] ( ): Saturated steam holding heat (kcal/kg) ( ): Saturation temperature (C) For Water How to read the graph The pressure differential to generate a flow rate of 25 L/min water is as follows.
Vibration resistance allows for normal operation up to 30 m/s2 (45 to 250 Hz), but continuous vibration may cause a decline in durability. Arrange piping to avoid excessive vibrations or shocks. I High-temperature type (H0, H4, H5) 1. For models with a heater, take care not to damage the insulation components of the lead wires and the connector section. 2.
To use the system in a magnetic field that exceeds this value, use a magnetic material to shield the sensor unit. 63 50 50 40 40 YES 100 200 300 400 500 100 200 300 400 500 NO Does the mounted load exceed the load given in the diagram? Piston speed (mm/s) Horizontal mounting Piston speed (mm/s) Vertical mounting Selection O.K.
Lateral load Operating pressure: 1 MPa 1000 200 300 500 Stroke Eccentric distance 100 100 Load weight (kg) 10 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 63 Allowable lateral load (N) 50 40 63 1 32 25 20 50 40 10 32 0.1 25 10 100 200 300 500 1000 Maximum piston
connector, refer to page 8-30-52. 8-29-1 2 Series CXS Specifications 15 6 10 20 25 32 Bore size (mm) Fluid Proof pressure Maximum operating pressure Minimum operating pressure Ambient and fluid temperature Piston speed Cushion Stroke adjustable range Port size Bearing type Air (Non-lube) 1.05 MPa 0.7 MPa 0.1 MPa 0.05 MPa 0.15 MPa 10 to 60C (No freezing) 30 to 600 mm/s 30 to 700 mm/s 30 to 300
ms) Switch output Hysteresis Hysteresis mode Variable from 0*2 Window comparator mode Short circuit protection Yes Voltage output Output type Voltage output: 1 to 5 V Voltage output: 0.6 to 5 V Output impedance Approx. 1 k Output type Current output: 4 to 20 mA Current output: 2.4 to 20 mA Analog output Current output Load impedance Maximum load impedance at power supply voltage of 12 V: 300
2 m 4 m 6 m 13 m Filtration efficiency 99% FQ1 HEPO 2 FGH100 to 300 FN The membrane element cannot be selected for FGH100.
-12 FH990-16 FH991-20 FH991-24 FH991-28 FH991-32 23 M8 x 1.25 Thread depth 8 35 6 84 180 2.4 3.4 28 35 M8 x 1.25 Thread depth 8 50 8 91 240 3.6 5.0 44 50 M8 x 1.25 Thread depth 9 62 10 103 300 5.4 7.8 62 77 M10 x 1.5 Thread depth 12 10 118 360 9.7 13.5 90 102 M10 x 1.5 Thread depth 12 5 133 340 10.6 14.4 115 Note) Both flange and thread connections are supported.
Fittings & Tubing Air Cylinders Rotary Actuators ARP20(K) 1021 ARP20(K) 1021 Rc1/4 0.50 0.25 0.45 0.40 Outlet pressure (MPa) Outlet pressure (MPa) 0.35 Set point 0.30 0.20 0.25 0.20 0.15 0.10 0.05 0.15 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.00 0 50 100 150 200 250 300 Flow rate (L/min (ANR)) Inlet pressure (MPa) 1021 1021 ARP30(K) ARP30(K) Rc3/8 0.50 0.25 0.45 Air Preparation Equipment 0.40
300 IRV Flow rate (L/min (ANR)) Inlet pressure (MPa) VEX ARP30(K) ARP30(K) Rc 3/8 SRH 0.50 0.25 SRP 0.45 0.40 SRF Outlet pressure (MPa) Outlet pressure (MPa) 0.35 Set point VCHR 0.30 ITV 0.20 0.25 0.20 IC 0.15 ITVX 0.10 PVQ 0.05 0.15 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.00 0 100 200 300 400 500 600 VEF VEP Flow rate (L/min (ANR)) Inlet pressure (MPa) VER ARP40(K) ARP40(K) Rc 1/2 VEA 0.50
300 IR Flow rate (L/min (ANR)) Inlet pressure (MPa) IRV ARP30(K) ARP30(K) Rc 3/8 VEX 0.50 0.25 SRH 0.45 0.40 SRP Outlet pressure (MPa) Outlet pressure (MPa) 0.35 Set point SRF 0.30 ITV 0.20 0.25 0.20 IC 0.15 ITVH 0.10 ITVX 0.05 0.15 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.00 0 100 200 300 400 500 600 PVQ Flow rate (L/min (ANR)) Inlet pressure (MPa) VY1 ARP40(K) ARP40(K) VBA VBAT Rc 1/2 0.50
300 Flow rate (l/min (ANR)) Inlet pressure (MPa) ARP30(K) ARP30(K) Rc3/8 0.50 0.25 0.45 0.40 Outlet pressure (MPa) Outlet pressure (MPa) 0.35 Set point 0.30 0.20 0.25 0.20 0.15 0.10 0.05 0.15 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.00 0 100 200 300 400 500 600 Flow rate (l/min (ANR)) Inlet pressure (MPa) ARP40(K) ARP40(K) Rc1/2 0.50 0.25 0.45 0.40 Outlet pressure (MPa) Outlet pressure (MPa)
INP1DELAY SEC screen No.21 "AL25Contact input signal detection 1" OFF detection timer 0 0 to 10 INP1OVER SEC screen No.22 screen Changing of "AL26Contact input signal detection 2" FLT OFF/WRN/FLT INP2ALARM No.23 "AL26Contact input signal detection 2" reading delay timer 0 0 to 300 INP2DELAY SEC screen No.24 "AL26Contact input signal detection 2" OFF detection timer 0 0 to 10 INP2OVER SEC
INP1DELAY SEC screen No.21 AL25Contact input signal detection 1 OFF detection timer 0 0 to 10 INP1OVER SEC screen No.22 screen Changing of AL26Contact input signal detection 2 FLT OFF/WRN/FLT INP2ALARM No.23 AL26Contact input signal detection 2 reading delay timer 0 0 to 300 INP2DELAY SEC screen No.24 AL26Contact input signal detection 2 OFF detection timer 0 0 to 10 INP2OVER SEC screen
Set range is 0 to 300 sec. to Contact input signal 2 OFF detection timer Setting and checking 17. Press the [SEL] key once. The set screen of contact input signal 2 OFF detection timer is displayed on the digital display. PV SV 18. Select contact input signal 2 OFF detection timer from the table below with [] key or [] key, and confirm by pressing SEL.
Set range is 0 to 300 sec. to Contact input signal 2 OFF detection timer Setting and checking 17. Press the [SEL] key once. The set screen of contact input signal 2 OFF detection timer is displayed on the digital display. PV SV 18. Select contact input signal 2 OFF detection timer from the table below with [] key or [] key, and confirm by pressing SEL.
C E D C E E (KF ) (K ) Fn Fd J K H B A G A mm A B C D E Fn Fd G H J K XLC-50 70 183 80 31 10.5 75 52 77 29 10.5 XLC-63 88 209 100 39 11 87 95 70 76.5 36 9 XLC-80 90 250 117 45.5 11 114 110 83 105 44 9 XLC-100 108 317.5 154 55 11 134 130 102 139 58 9 XLC-160 138 339 200 65 11 190 180 153 124 62 12.5 10 XL-OMV0002 5. 200 1680 100 100,160[ ]18 12 Assy O XLC-16,XLC-25,XLC-40,XLC-50,XLC-63,
(PAT.PEND) Over length L(mm) Gripping moment Weight (g) Bore size (mm) Model (Nm) L MHW2-20D 68 300 20 0.30 MHW2-25D 510 25 0.73 78 905 MHW2-32D 32 93.5 1.61 2135 MHW2-40D 117.5 40 3.70 5100 Auto switch mounting at 4 locations MHW2-50D 154 50 8.27 At the pressure of 0.5 MPa MHZ Two finger types available.