250 150 Flow rate l/min (ANR) Relief flow rate l/min (ANR) Supply pressure P1 MPa IR1010-01 IR1010-01 IR1010-01 Conditions: Supply pressure 0.7MPa Conditions: Back pressure 0.7MPa 0.4 0.204 0.7 Set pressure P2 MPa 0.6 Set pressure MPa Set pressure MPa 0.202 0.3 0.5 Setting point 0.4 0.200 0.2 0.3 0.198 0.2 0.1 0.1 0.196 0 0.2 0.1 0.3 0.4 0.6 0.5 0.8 0.7 0.9 0 50 100 150 200 250 300 350 1.0
: 201 to 300mm 80 40 50 50 20 20 Load weight m (kg) Load weight m (kg) Load weight m (kg) 20 10 10 10 63 63 63 5 5 5 50 50 50 [Example ] 40 40 40 1 1 1 70 100 300 500 1000 70 100 300 500 1000 70 100 300 500 1000 Stroke (mm) Stroke (mm) Stroke (mm) 2.
Keep the air flow within the rated flow to prevent and outflow of a lubricant to the outlet side. 150 820 330 Polycarbonate Bowl material Bowl guard Drain capacity (cm3) Construction Weight (kg) Standard Option 8 45 25 Relieving type 0.59 1.25 0.44 Note) When N is specified in the end of part number of auto drain, applicable tube O.D should be 3/8". Accessory part no.
kPaON3(50 kPa)ON 1.5 F42.5 GH64 150 kPa (100 kPa200 kPa) 80 kPa220 kPaOFF (62 ) ISA3-F ISA3-G ISA3-H 1 m 1 m 1 m ON [mm] ON [mm] ON [mm] [kPa] [kPa] [kPa] 3 m 3 m 3 m ON [mm] ON [mm] ON [mm] [kPa] [kPa] [kPa] 5 m 5 m 5 m ON [mm] ON [mm] ON [mm] [kPa] [kPa] [kPa] -17No.PS-OMR0001CN-J 2 ON OUT 10090%0%() (0.1 mm0.09 mm0 mm) 1.5 F42.5 GH64 200 kPa 90% -ISA3-F ISA3-G ISA3-H 1 m 1 m 1 m
2.0% F.S. or less (0 to 50C, based on 25C)NPN open collector Max. load current: 80 mA; Max. applied voltage: 30 V; Internal voltage drop: 1 V or less (with load current of 80 mA)PNP open collector Max. load current: 80 mA; Internal voltage drop: 1.5 V or less (with load current of 80 mA)NPN or PNP open collector Flow rate per pulse: 100 l/pulse, 10.0 ft3/pulseON time per pulse
2.0% F.S. or less (0 to 50C, based on 25C)NPN open collector Max. load current: 80 mA; Max. applied voltage: 30 V; Internal voltage drop: 1 V or less (with load current of 80 mA)PNP open collector Max. load current: 80 mA; Internal voltage drop: 1.5 V or less (with load current of 80 mA)NPN or PNP open collector Flow rate per pulse: 100 l/pulse, 10.0 ft3/pulseON time per pulse
2.0% F.S. or less (0 to 50C, based on 25C)NPN open collector Max. load current: 80 mA; Max. applied voltage: 30 V; Internal voltage drop: 1 V or less (with load current of 80 mA)PNP open collector Max. load current: 80 mA; Internal voltage drop: 1.5 V or less (with load current of 80 mA)NPN or PNP open collector Flow rate per pulse: 100 l/pulse, 10.0 ft3/pulseON time per pulse
550 480 4 Long 0.33 to 1.05 85 170 Long 1,000 870 5 0.37 to 1.24 150 300 Long 1,500 1,300 6 0.40 to 1.32 230 460 110 100 1 Short 1.00 to 3.05 18 36 160 140 1 1/4 Short 0.90 to 2.67 27 54 270 230 1 1/2 Short 1.10 to 3.29 45 90 270 230 2 Middle 0.68 to 2.05 45 90 Component Parts IF33-10 500 420 2 1/2 Middle 0.74 to 2.30 80 160 Material No.
2.0% F.S. or less (0 to 50C, based on 25C)NPN open collector Max. load current: 80 mA; Max. applied voltage: 30 V; Internal voltage drop: 1 V or less (with load current of 80 mA)PNP open collector Max. load current: 80 mA; Internal voltage drop: 1.5 V or less (with load current of 80 mA)NPN or PNP open collector Flow rate per pulse: 100 l/pulse, 10.0 ft3/pulseON time per pulse
200 150 100 0 50 Supply pressure (kPa) Supply pressure (kPa) 870 Air Catch Sensor Series ISA2 Response Time (Typical example) Response time changes with detection distance and piping length.
Peltier-type Chiller Thermo-con/ Compact Type Air-cooled Compact 130 mm x 210 mm x 150 mm Height Width Depth Low-noise design (at low load): 37 dB 130 mm 150 mm Display/Operation panel 210 mm Circulating fluid level gauge Dustproof filter Replaceable Cooling capacity: 220 W Superior temperature control Temperature stability: 0.1C Now only takes about 41 seconds to lower the temperature by
Description Decimal Common Format "Data-INT" "Data-SINT" Input 100 100 Output 150 150 Configuration 105 105 (5) Size: Perform setting as shown below. Description Decimal Common Format "Data-INT" "Data-SINT" Input MIN. 1 word MIN. 2 byte MAX.110 words MAX.220 byte Output MIN. 1 word MIN. 2 byte MAX.110 words MAX.220 byte When configuration assembly fundtion is not used: Set to "0".
HRR012/018-A-10-* 45 70 HRR012/018-A-20-* 61 80 HRR012/018-A-20-U 50 80 Model A B In the case of option Z, without bypass valve Fig. 9-1 Outline dimensions (HRR012/018-A-10/20-) 9.2 Outline dimensions HRR Series 9-6 HRX-OM-W002 Chapter 9 Documents 9.2.2 HRR012/018-W-10/20For Option Y(With feet and no Rack Mounting bracket), refer to [6.5 Option Y(With feet and no Rack Mounting bracket).
P-80 (D) This catalog is printed on recycled paper with concern for the global environment.
Caution VQ VKF Dimensions VQZ VP3145-DZA1-X81 MAX.10 134 35 VZ 87.4 VS 21 EXH.1 51 VFN EXH.2 71 80 (Non-locking) Manual override 6 to 8 Applicable cable O.D.
Valve specifications Electricity specifications 0.1 MPa Minimum operating pressure 0.15 MPa 0.15 MPa 10 to 50C (1) Ambient and fluid temperature 10 to 50C (1) 10 to 50C (1) Maximum operating frequency 20 Hz 5 Hz 20 Hz Individual EXH Pilot valve EXH Common exhaust Not required Lubrication Non-locking push type/Slotted locking type (tool required) as an option Pilot valve manual override 150
DB mIB ID X U VB VA H T PW 2-Rc P (plug) Rc 1/8 unlocking port Unlocks when pressurized GC GA XAH7 depth XL 2-Rc P PB A + Stroke E B + Stroke FA FB C + Stroke PA + Stroke GB Q G J K IE S XAH7 depth XL (mm) MLGPM, MLGPL common dimensions Standard stroke (mm) Bore size (mm) B C DA FA FB G GA GB GC H HA IA IB IC ID IE 14 11 100 44 16 12 44 54 10 120 M6 34 52 14 4 14 40 25, 50, 75 100, 125, 150
"n" depends on the station number setting. -80- Programmable PC or PLC...etc LECSC Driver (RWwn) LECSC Driver Programmable PC or PLC...etc (RWrn) Address No. Signal name (Note 1) (Note 1) Address No.
Hz: 9.8 m/s2 Acceleration Sweep Count for X,Y,Z: 10 times (80 minutes in each direction) Conforms to IEC 68-2-6; 10-57 Hz: 0.15 mm Constant Amplitude 57-150 Hz: 19.6 m/s2 Acceleration Sweep Count for X,Y,Z: 10 times (80 minutes in each direction) 9 PneuAlpha Hardware Specification 2 Table 2.8:Environmental and Electrical Specications Insulation Resistance 7 Mohm at 500V DC per EN60730-1
Valve Solenoid Max.operating frequency 20Hz 5Hz Individual EXH Pilot valve EXH Not required Lubrication Non-locking push style/Locking slotted style Manual override 150/30 m/s2 Shock/Vibration resistance (2) Dust proof Enclosure 12V, 24V DC and 100V, 110V, 200V, 220V AC 10% of rated voltage Coil rated voltage Allowable voltage Class B or equivalent Coil insurance 1W DC (42mA), 0.5W DC (21mA