Note 7) The display unit is comformed to CE mark. 4 Series PF2A Flow Characteristics (Pressure Loss) PF2A710,510 PF2A750,550 PF2A711,511 3.0 1.0 10 Pressure loss (kPa) Pressure loss (kPa) Pressure loss (kPa) 2.5 0.8 8 2.0 6 0.6 1.5 0.4 4 1.0 0.2 2 0.5 Flow rate (l/min) 0 100 10 25 50 75 5 2.5 7.5 0 5 10 15 20 25 30 40 35 45 50 0 1 10 Flow rate (l/min) Flow rate (l/min) PF2A721,521 PF2A751,551
D-A93 D-M9B D-M9N, D-M9P Type Load voltage Load current range Indicator light Application Reed auto switch Solid state auto switch 24 VDC, 100 VAC 24 VDC (10 to 28 VDC) 28 VDC or less 5 to 40 mA, 5 to 20 mA 2.5 to 40 mA 40 mA or less Relay, PLC 24 VDC Relay, PLC IC circuit, Relay, PLC Air Preparation Equipment Pressure Control Equipment Flow Control Equipment Pressure Switches/ Pressure Sensors
A A F F A F L L L 1 N = 0.2248 lbf 6 6 6 L=80mm L=80mm L=80mm 0.05 0.06 MXPJ6-5 MXPJ6-10 MXPJ6-5 MXPJ6-10 MXPJ6-5 MXPJ6-10 MXPJ6-5 MXPJ6-10 0.04 MXPJ6-5 MXPJ6-10 MXPJ6-5 MXPJ6-10 0.05 0.04 Table deflection (mm) Table deflection (mm) Table deflection (mm) 0.03 0.04 0.03 0.02 0.03 0.02 0.02 0.01 0.01 0.01 0 10 20 30 40 Load (N) 0 10 20 30 50 Load (N) 0 10 20 30 40 Load (N) 40 10 10 10 L=100mm
Outlet: 60 Hz Outlet: 60 Hz 20 20 0.1 0.1 10 10 Outlet: 50 Hz Outlet: 50 Hz Return port Allowable operating range Return port Allowable operating range 0 0 0 5 10 15 20 25 30 0 5 10 15 20 25 30 Circulating fluid flow rate [L/min] Circulating fluid flow rate [L/min] 202 Thermo-chiller Basic Type HRSE Series Dimensions HRSE012/018/024-A-10/20/23 Ventilation air outlet Ventilation air inlet
MXQ 6 MXQ 8 MXQ12 MXQ16 MXQ20 MXQ25 10, 20, 30, 40, 50 10, 20, 30, 40, 50, 75 10, 20, 30, 40, 50, 75, 100 10, 20, 30, 40, 50, 75, 100, 125 10, 20, 30, 40, 50, 75, 100, 125, 150 10, 20, 30, 40, 50, 75, 100, 125, 150 2 Series MXQ Theoretical Output IN OUT Application of the dual rod system generates double the output of conventional cylinders.
25 MB MA HC HE KB KA LA LB LC PA PB PD PC ME MD MIS12-10 MC HD HA, HB JB JA N Model 48 38 28 39 29 19 MIS12-30 MIS12-20 13 10 7 6 4 3.5 17.5 11.6 2.3 M2.6 x 0.45 19 4 M4 x 0.7 6 11 5 2.5H9 0 +0.025 18 6 MIS20-30 MIS20-20 MIS20-10 7 40.5 30.5 20.5 52 42 32 8.5 17.5 4H9 0 +0.030 5 5 2.8 M3 x 0.5 26 6 M6 x 1 9 25 12 8 10 15 14 26 10 Series MIW/MIS Finger options Tapped on upper and lower faces
2 mm 10% Supply voltage 10 to 30 VDC 10 to 30 VDC Output N.O., PNP N.O., PNP Continuous load current 150 mA 100 mA Response frequency 30 Hz 25 Hz Housing material PBT PA6, PBT Clamping side: Red Clamping side: Red Output indication Unclamping side: Yellow Unclamping side: Yellow Voltage indication Green Green Note) Switch specifications are corresponding to manufacturers technical information
: 10 8-6: 5; 8-8: 5, 8-10: 5 Max. operating frequency (cycle/sec) 8-6: 10; 8-8: 10, 8-10: 20 8-6: 3; 8-8: 3, 8-10: 2 Lubrication Not required Manual override Non-locking push type Enclosure Dusttight Coil rated voltage 100 VAC, 110 VAC, 200 VAC, 220 VAC, 24 VDC Allowable voltage range (%) 15 to +10% of rated voltage Coil insulation Class B or equivalent 50 Hz 5.6 Apparent Inrush 60 Hz 5.0
25 MB MA HC HE KB KA LA LB LC PA PB PD PC ME MD MIS12-10 MC HD HA, HB JB JA N Model 48 38 28 39 29 19 MIS12-30 MIS12-20 2.5H9 0 +0.025 13 10 7 6 4 3.5 11.6 2.3 M2.6 x 0.45 19 4 M4 x 0.7 6 17.5 11 5 18 6 MIS20-30 MIS20-20 MIS20-10 7 40.5 30.5 20.5 52 42 32 4H9 0 +0.030 8.5 17.5 5 5 2.8 M3 x 0.5 26 6 M6 x 1 9 25 12 8 10 15 14 26 10 Series MIW/MIS Finger options Tapped on upper and lower faces
consumption (Controller) 200 mA or less 130 mA or less 200 mA or less 100 mA or less 100 mA or less Compatible encoder Incremental A/B phase (800 pulse/rotation) Protocol EtherCAT*2 EtherNet/IP*2 PROFINET*2 DeviceNet IO-Link Communication specifications Applicable system Version*1 Conformance Test Record V.1.2.6 Volume 1 (Edition 3.14) Volume 2 (Edition 1.15) Specification Version 2.32 Volume
1% F.S.30 msAir/Inert gas0 to 50C (With no condensation)0.88 MPa0.05 MPa to supply pressureSet pressure to 0.88 MPa (VY1 01)1 to 5 VDC, 0 to 10 VDC, 4 to 20 mA DC, 0 to 20 mA DC12 VDC ? 10%, 24 VDC ? 10%, 1.8 W or lessDIN terminalCable O.D. ?
For details, refer to 3 point preset counter/CEU1 on page 10-12-30, and Multi counter/CEU5 on page 10-12-27 respectively.
For details, refer to 3 point preset counter/CEU1 on page 10-12-30, and Multi counter/CEU5 on page 10-12-27 respectively.
A2 10 11 12 17 Model A1 6 10 10 11 MXF8 MXF12 MXF16 MXF20 A3 6 10 10 11 A4 21 23 28 34 A5 21 23 28 34 A6 10 11 12 17 Graph (2) Allowable Moment Coefficient: Note) Note) MXF8 MXF12 MXF16 MXF20 1.0 Allowable Moment Coefficient: Note) 16 mm for MXF8-10 only. 0.7 Stroke (mm) Table (4) Maximum Allowable Moment: Mmax (Nm) 0.5 0.4 Model 10 0.56 100 18.27 75 7.96 13.70 50 3.34 5.69 9.14 30 0.98
0.05 to 0.7 MPa VP4 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 1 2 0.1 to 0.4 MPa VZS 0.08 MPa 1a Filter element XTO-1889-10 VFS 2 VA AC, 2 W DC 24 VAC, DC or less: 50 mA 100 VAC, DC: 20 mA Plug-in type VVZS2000-14A Non plug-in type IS1000-00-X204 Pressure switch
For valve weight, refer to page 2-3-10.
Indicator light IS 3 2 Lead wire R 1/8 Port size ZSM 65 g Weight PF2 IF Electrical Specifications Data ZSM1-115 Supply voltage 4.5 to 28 VDC Output (Open collector) 30 V, Max. 100 mA Current consumption 10 mA or less (24 VDC) ZSM1-121 Supply voltage 100 VAC Operating current range 24 V or less: 50 mA, 48 V: 40 mA, 100 V: 20 mA Max. contact capacity AC 2 VA, 2 W DC How to Order ZSM1 1 15 Lead
D-Z73 D-Y59B D-Y59A Load voltage 24 VDC,100 VAC 24 VDC (10 to 28 VDC) 28 VDC or less Load current range Indicator light Application Relay, PLC 24 VDC Relay, PLC IC circuit, Relay, PLC 5 to 40 mA, 5 to 20 mA 5 to 40 mA 40 mA or less PLC: Programmable Logic Controller Refer to page 889 for the applicable auto switch list.
Mbit/sec Rated voltage 24 VDC Input and control unit power supply: 24 VDC 10% Solenoid valve power supply: 24 VDC + 10%/5% (with power drop warning at approx. 20 V) Power supply voltage range Communication power supply for DeviceNet 11 to 25 VDC 200 mA or less (single GW unit) Current consumption Communication power supply for DeviceNet 50 mA or less Input Unit Manifold Number of inputs
Withstand pressure 600 kPa Detection nozzle 1.5 *3 Consumption flow rate 5 L/min or less 12 L/min or less 22 L/min or less Power supply voltage 24 VDC 10%, Ripple (p-p) 10% or less (With power supply polarity protection) Current consumption 25 mA or less Switch output 1 output (NPN or PNP) Maximum load current 10 mA Maximum applied voltage 26.4 V Residual voltage 1 V or less (at 10 mA) Short